Exploded view Microprocessor air baffle Microprocessor air baffle Microprocessor heat-sink assembly Microprocessor heat-sink assembly Microprocessor Microprocessor Memory Memory VRM VRM Power supply blank filler Power supply blank filler Hot-swap power supply Hot-swap power supply System board shuttle assembly Power cage and backplane assembly Power cage and backplane assembly Chassis Chassis Front bezel assembly Front bezel assembly Hard disk drive Hard disk drive Hard disk drive blank bezel Hard disk drive blank bezel DASD backplane with bracket assembly Thermal baffle kit Fan assembly PCI riser card Top cover Top cove System board shuttle assembly DASD backplane with bracket assembly Thermal baffle kit Thermal baffle kit Fan assembly PCI riser card

This parts listing supports the IBM eServer xSeries 345 type 8670 (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X

Note: Replacement part numbers (FRUs) must be serviced only by qualified field service technicians. Customer replaceable units (CRUs) can be replaced by the customer.

Item Description Part number FRU/CRU

1

Microprocessor air baffle
(models 11X, 12X, 21X, 22X, 23X, 31X, 32X, 3PX, 3WX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X) 24P1284 CRU

2

Microprocessor heat-sink
(all models) 25P6309 FRU

3

Microprocessor
2.0 GHz/400 MHz (512 KB L2 cache) (models 11X, 12X, 13X, 14X) 25P2671 FRU
2.2 GHz (models 21X, 22X, 23X) 32P8582 FRU
2.4 GHz (models 31X, 32X; 2 per on model 24X) 37L3570 FRU
2.4 GHz (models 3PX, 3WX, 3YX, 3ZX) 59P4937 FRU
2.67 GHz (models 51X, K1X; 2 per on models 52X, K2X) 59P4840 FRU
2.8 GHz (models 61X, L1X; 2 per on models 62X, L2X) 59P4845 FRU
3.06 GHz (512 KB L2 cache) (models 71X, 72X, 7RX, M1X, M2X) 71P8340 FRU
3.06 GHz (1 MB L2 cache) (models 91X, F1X) (2 per on models 9RX, FRX) 88P9782 FRU
3.2 GHz (models J1X, JAX) 13N1510 FRU
3.2 GHz (512 KB L2 cache) (model G1X, GAX, GBX, GMG, G1X, G4X) 90P0969 FRU

4

Memory
256 MB DDR SDRAM DIMM (models 11X, 12X, 21X, 22X, 31X, 32X, 3WX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X, L1X, L2X, M1X, M2X) 09N4306 CRU
512 MB PC2100ECC (models 23X, 3PX, 3YX, 3ZX, G1X) 09N4307 CRU
256 MB PC2100 (models K1X, K2X, L1X, L2X, M1X, M2X, F1X, FRX) 73P2872 CRU
1 GB PC2100 (4 per on model 24X) 09N4308 CRU

5

VRM
VRM card 9.05P (VRM card 9.05P (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X) 49P2129 FRU
VRM card 9.1 (models 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X) 49P2010 FRU

6

Power supply blank filler
(models 11X, 21X, 31X) 01R0601 CRU
(models 71X, 91X,FLX, G1X, J1X, M1X) 73P6163 CRU

7

Hot-swap power supply
350 W (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 51X, 52X, 61X, 62X, K1X, K2X, L1X, L2X) 49P2033 CRU
514 W redundant (2 per on models 71X, 91X, G1X, F1X, J1X) (1 per on models 72X, 7RG, 9RX, M2X, FRX, M1X, ) 49P2167 CRU

8

System board shuttle
(models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X) 23K4454 replaces 48P9026 FRU
(models 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, K1X, K2X, L1X, L2X) 23K4455 replaces 71P8058 FRU
(models 71X, 72X, 7RGX, 91X, 9RX, F1X, FRX, G1X, J1X, M1X, M2X) 13M7978 replaces 13M7920, 23K4456 FRU

9

Power cage
(models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 51X, 52X, 61X, 62X, K1X, K2X, L1X, L2X) 49P2037 FRU
(models 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, M1X, M2X) 49P2169 FRU

10

Chassis
(models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X, L1X, L2X) 01R0588 FRU
(models 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, M1X, M2X) 73P6161 FRU

11

Front bezel
(models 11X, 12X, 21X, 22X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X, L1X, L2X, M1X, M2X) 32P1878 CRU
(model 23X) 01R0664 CRU
(model 24X) 01R0682 CRU
(models 3PX, 3WX, 3YX, 3ZX) 73P6635 CRU

12

Hard drive
36 GB 15 000 rpm SCSI (3 per on models 12X, 22X, 32X) 06P5778 CRU
36 GB (models 3PX, 3WX, 3YX, 3ZX) 90P1341 CRU
36.4 GB 10 000 rpm (3 per on models 52X, 62X, 72X, 7RG, 9RX, K2X, L2X, M2X, FRX) 32P0729 CRU
36 GB (models 12X, 22X, 32X) 06P5778 CRU
73 GB 10 000 rpm (2 per on model 23X) (6 per on model 24X) 32P0759 CRU
73 GB (model 3ZX) 90P1340 CRU

13

Hard drive blank bezel
(all models) 00N7259 CRU
(models 11X, 12X, 21X, 22X, 31X, 32X, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X) 06P6245 CRU

14

Hard drive backplane with bracket assembly
(all models) 59P5856 FRU

15

Thermal baffle kit
(all models) 01R0614 FRU

16

Fan
80 mm hot-swap (all models) 01R0587 CRU

17

PCI riser card
(models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X, L1X, L2X) 48P9027 FRU
(model 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, M1X, M2X) 73P6591 FRU

18

Top cover
(models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 7RG, 91X, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X) 01R0595 CRU
(models 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, M1X, M2X) 73P6162 CRU
. Alcohol wipe kit
(all models) 59P4739 FRU
. Thermal grease kit
(all models) 59P4740 FRU
. Memory DIMM baffle
(models 41X, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, K1X, K2X, L1X, L2X) 90P4079 FRU
. 3.0 V battery
(all models) 33F8354 FRU
. Battery pack
RAID adapter (models 12X, 22X, 32X, 52X, 62X, 72X, K2X, L2X, M2X) 25P3482 CRU
3U/2U (models 7RG, 9RX, FRX) 02R0986 CRU
. Cable management arm assembly
(all models) 01R0591 CRU
. Cables
2-drop IDE (models 23X, 24X) 01R0636 CRU
SCSI signal (all models) 32P1871 CRU
USB (all models) 32P1872 CRU
Operator information card to system board (all models) 32P1870 CRU
Diskette drive to operator information card (models 11X, 12X, 21X, 22X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X, L1X, L2X, M1X, M2X) 32P1869 CRU
CD signal to system board (models 11X, 12X, 21X, 22X, 31X, 32X, 51X, 52X, 61X, 62X) 32P1874 CRU
Fan 2-drop (all models) 32P1873 FRU
Power 2-drop Y (models 23X, 24X) 01R0638 FRU
. CD-ROM
24x, primary (all models) 06P5263 CRU
24x, alternate (all models) 19K1523 CRU
24x, alternate (all models) 33P3231 CRU
. Jumper cord
2.8 m (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X, L1X, L2X, M1X, M2X) 36L8886 CRU
. Diskette drive
12.7mm 1.44MB slim high (models 11X, 12X, 21X, 22X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X, L1X, L2X, M1X, M2X) 36L8645 CRU
. DVD 8x slim high
(models 3PX, 3WX, 3YX, 3ZX) 24P3637 CRU
. EIA bracket assembly
(all models) 01R0593 FRU
. Interposer card
(all models) 48P9028 FRU
. Mechanical miscellaneous parts kit

(models (11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 7RG, 91X, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X)

  • Clip, VRM metal (2)
  • Filler, standard PCI blank (3)
  • Filler, low profile PCI blank (2)
  • Latch, standard PCI retention (2)
  • Guide, PCI card (3)
  • Latch, shuttle locking (2)
  • Spring, shuttle latch (2)
  • Latch, low profile PCI retention (3)
  • Lid, low profile PCI retention (2)
  • Latch, PCI cage retention (2)
  • Light box, switch card (1)
  • Latch, cable strain relief (2)
  • Holder, diskette drive wire spring (2)
  • Holder, CD-ROM wire spring (2)
  • Latch, hard disk drive backplane retention (3)
  • Screw, M3.5x5 (17)
  • Screw, M3.5x10 (10)
  • Screw, number 4-40 standoff (4)
  • Screw, 0.8mm standoff (2)
01R0589 FRU
. Mechanical miscellaneous parts kit
(models 71X, 72X, 7RG 91X 9RX F1X, FRX, G1X, M1X, M2X, F1X) 73P6127 FRU
. Operator information card
(all models) 48P9029 FRU
. Power cord
2.7 m/9 foot (all models) 6952300 CRU
. RAID adapter
(models 12x, 22x, 32x, 3PX, 3WX, 3YX, 3ZX, 52X, 62X, 72X)

Note: CRU 02R0970 includes the battery
02R0970 replaces 32P0016 CRU
(models 7RG, 9RX, FRX) 71P8627 CRU
. Retain module
(models 11X, 12X, 21X, 22X, 23X, 24X, 32X) 06P6350 FRU
(models 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X) 71P8107 FRU
. 2U left and right slide
(models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X, L1X, L2X) 90P4011 CRU
(models 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, M1X, M2X) 90P4062 CRU
. System service label
(models 11X, 12X, 21X, 22X, 31X, 32X) 01R0594 FRU
(models 23X, 24X, 3PX, 3WX, 3YX, 3ZX) 01R0667 FRU
(models 51X, 52X, 61X, 62X, K1X, K2X, L1X, L2X) 01R1438 FRU
(models 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, M1X, M2X) 73P6164 FRU
. VRM clip
(all models) 31P6025 FRU

 