IBM Support

PowerHA Enterprise Edition Support Cross Reference

How To


Summary

The following shows the supported combinations available within PowerHA Enterprise Edition. The NPIV support was confirmed with PowerHA development, though no separate support flashes state it.

Objective

 Replication Option 
 HA version(minimum) 

 AIX 5.3 
 AIX 6.1 
 AIX 7.1 
 VIOS 
 NPIV 
GLVM synchronous
YES – ML2
YES
YES
YES
GLVM asynchronous
 NO 
Yes-TL2 SP3
YES
YES
SVC Metro Mirroring
YES
YES
YES
YES -  VIOS 1.5 
HA 5.4.1+IZ13774 HA 5.5 HA 6.1
YES –   FLASH10691 
HA 5.4.1+IZ02620HA 5.5HA 6.1

YES
SVC Global Mirroring
YES – TL9 RSCT 2.4.10.0

YES–TL2 RSCT 2.5.2.0

YES
Same as Metro
above
except no 5.4.1
support
YES
Storwize v7000 replication
TL11, SP01RSCT 2.4.13.0

TL04 SP03 RSCT 3.1.0.3

TL0 SP02
RSCT 3.1.0.3
Same as Metro
above
except no 5.4.1
support
YES
ESS Metro
5.1
YES
YES
YES
YES
DS6k/8K Metro
YES-ML1
YES
YES
YES
EMC SRDF (sync and async)DMX-3DMX-4   FLASH10703 
YES – TL9 RSCT 2.4.12.0

YES–TL2 SP1
RSCT 2.5.4.0
YES
 Not vSCSI 
DS8700/DS8800 Global Mirror
YES – TL9 RSCT 2.4.12.0

YES–TL2 SP1
RSCT 2.5.4.0
YES
RSCT
3.1.0.0
 Not vSCSI 
Hitachi TrueCopy sync and HUR async
YES – TL9 RSCT 2.4.12.0

YES–TL2 SP1
RSCT 2.5.4.0
 Not vSCSI 
 NO 
YES - TL5 RSCT 3.1.0.3
YES –
RSCT 3.1.0.3
 Not vSCSI 
YES – TL9 RSCT 2.4.13.0

YES – TL5 RSCT 2.5.5.2
YES - RSCT 3.1.0.3
 NO 


Addition EMC/SRDF software requirements:

·JAVA
·IBM’s Java 1.4 preferred
·EMC SYMCLI
·SYMCLI.SYMCLI.rte 7.0.0.0

The SYMCLI command line interfaces must be installed in the default location, /usr/symcli/bin

·EMC Storage Subsystem
·DMX-3 with microcode 5772.103.93 or higher
·DMX-4 with microcode 5773.134.94 or higher
·V-MAX with microcode 5874.188.156 or higher
·PowerPath
·5.3.0.0
·cluster.es.sr.rte
·cluster.es.sr.cmds
·cluster.msg.en_US.sr


Additional DS8700 Global Mirror software requirements

·DS8700 Firmware Software Bundle V75.1.145.0 or later
·DSCLI version 6.5.1.203 or later
·JAVA
·Additional filesets from 6.1 SP3 specifically above what comes on 6.1 EE base media

·cluster.es.genxd
·cluster.msg.en_US.genxd


Additional Hitachi software requirements

·USPV Microcode 60-06-05/00, or later
·CCI Version 01-23-03/06 or later
·Additional filesets from 6.1 SP3 specifically above what comes on 6.1 EE base media

·cluster.es.tc
·cluster.msg.en_US.tc


Additional HP software requirements

The following HP software and microcode were used as part of the testing:

1. HP StorageWorks XP Continuous Access Software (no version needed)2. HP RAID Manager: 1.25.11 3. XP 24000 Microcode: 60-08-08-00/004. XP 12000 Microcode: 50-09-98-00/085. MPIO: MPIO ODM (5403) devices.fcp.disk.HP.xparray.mpio.rte 5.4.0.3


Remember that support is contingent on the common denominator across all the pieces. For example, SVC Metro Mirroring is supported at HA 5.2 and above. However, it is NOT supported in a VIOS environment in 5.2. Hopefully this chart makes sense. Any questions feel free to email me at sbodily@us.ibm.com

Document Location

Worldwide

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSB2MZ","label":"High Availability Cluster Multi-Processing (HACMP) for AIX"},"ARM Category":[],"Platform":[{"code":"","label":"Platform Independent"}],"Version":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
19 October 2021

UID

TD105440