If you are having a problem with triggered events not showing up in the Monitor event log, restart the Monitor job.  Especially if you can see instances that the threshold is exceeded, but no trigger is occurring. 

First, end the monitor server with:

   QSYS/SBMJOB CMD(CALL PGM(QSYSDIR/QNAVMNSRV) PARM(*STOP)) CCSID(37)

       pre-Q4 2024 PTF: CALL PGM(QSYSDIR/QNAVMNSRV) PARM(*STOP)

Then, end and restart the ADMIN1 server:

    > ENDTCPSVR SERVER(*IAS) INSTANCE(ADMIN1)

    > STRTCPSVR SERVER(*IAS) INSTANCE(ADMIN1)

Monitors might not be triggered correctly if the IBM Navigator PTF is installed without first stopping the Monitor job.