(6320, 6321, 632B, 632C, 6330, 6331, 6333, 6336, 6337) Optical storage unit reference codes

An optical storage unit failure occurred.

Notes:
  1. If the system is available, use online diagnostic tests when possible.
  2. Use the Hardware Service Manager (HSM) verify function (via DST or SST) and verify that the unit is operating correctly.
  3. Search the problem log (WRKPRB) for a recent optical storage entry that may assist in analyzing the problem. The WRKPRB entry will provide a unit reference code that can be found in the following table.

Perform the following:

  1. If the system is available, attempt the failing operation again with an optical media that is known to be good.

    Does the operation complete successfully?

For more on the Failing Item column entries, see Table 2. Optical storage unit failing items details, which follows the reference code table below.

Table 1. (6320, 6321, 6330, 6331, 6333, 6336, 6337) Optical storage unit reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
C000 System log entry only, no service action required

No action is required. This reference code is logged for information only.


C002 SCSI selection or reselection timeout occurred
C010 Undefined sense key returned by device
C020 Device internal configuration error
C100 SCSI bus command error occurred
C110 SCSI command timeout occurred
C210 Unexpected device condition recovered

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


C300 Media or device error occurred

Perform the following:

  1. Clean the disk.
  2. Attempt the failing operation again.
  3. If this does not correct the problem, exchange the failing items.
C301 Media or device error occurred

Dust check encountered. The optical media or the optical lens of the drive is dirty.

Clean the optical drive and the media contained in the drive.


C302 Media or device error occurred

The device encountered an 'out of spare sectors' condition when writing to the media. The media can no longer be written to but is still readable.

Clean the optical drive and the media contained in the drive.


C303 Media had an unknown format

No action required. This reference code is logged for information only.


C333 Incompatible media was detected

Perform the following:

  1. Verify that the disk has a supported format.
  2. If the format is supported, clean the disk and attempt the failing operation again.
  3. If the operation fails again and results in the same reference code, ask your media source for a replacement disk.
C400 Interface error detected by device
C402 Licensed Internal Code error

Ask your next level of support for assistance.

CFF2 Recovered from device not ready - Start Unit issued

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


CFF4 Internal device error occurred
CFF6 Device successfully recovered from a temporary error

No action is required. This reference code is logged for information only.


CFF7 Recovered device error

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


CFFE Recovered SCSI bus error

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


FF09 Licensed Internal Code for optical device was not upgraded

This reference code is logged for information only.


FF3D Recovered IOA error

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


FF6D Recovered System bus error

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


Table 2. (6320, 6321, 6330, 6331, 6333, 6336, 6337) Optical storage unit failing items details

Failing Item Description Document Description
46G3532 CD-ROM device with tray Repair and Parts; removal and installation procedures
88G4918 CD-ROM device, Apex part Repair and Parts; removal and installation procedures
CDTRAY Flex cable on tray assembly See the service documentation for instructions.
CNVTCRD Converter card See the service documentation for instructions.
DEVTERM Bus Terminator See the service documentation for instructions.
MEDIA Optical Media System operation information
STORIOA Storage I/O adapter See the service documentation for instructions.

Table 3. (632B) Optical storage unit reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
CFC1 Virtual media list access problem

A virtual optical device cannot access the file containing the list of volumes.

On this partition and the Network File System server, ensure the proper file is specified and proper authority is granted.

CFC2 Error reading virtual volume list

A non-recoverable error was detected while reading the list of volumes.

Check for errors on the Network File System server and resolve them. Then retry the operation. If the failure reoccurs, contact your hardware service provider.

CFC3 Virtual media volume list is not valid

The data in the list of volumes is not valid.

On the Network File System server, ensure that the proper file is specified, that all files are entered correctly, that there are no blank lines, and that the character set used is valid.

CFC4 Virtual optical volume access problem

A virtual optical device cannot access the file containing the specified optical volume.

On the Network File System server, ensure the proper file is specified in the list of volumes, and that the proper authority is granted.

CFC5 Error reading virtual optical volume

A non-recoverable error was detected while reading a virtual optical volume.

Check for errors on the Network File System server and resolve them. Then retry the operation. If the failure reoccurs, contact your hardware service provider.

CFC6 Virtual optical volume is not valid

The file specified does not contain data that can be processed as a virtual optical volume.

On the Network File System server, ensure all the files specified in the list of optical volumes are correct.

CFC7 Virtual optical device detected error

A virtual optical device detected an error reported by the Network File System server that cannot be recovered.

Check for errors on the Network File System server and resolve them. Then retry the operation. If the failure reoccurs, contact your hardware service provider.

CFC8 Virtual optical device error

A virtual optical device encountered a non-recoverable error.

Contact your next level of support for assistance.

Table 4. (632B) Optical storage unit failing items details

Failing Item Description Document Description
NEXTLVL Call your next level of support for assistance Call your next level of support for assistance
SVCDOCS Customer engineer directed to system problem analysis See the service documentation for instructions.

Table 5. (632C) Optical storage unit reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
C000 System log entry only, no service action required

No action is required. This reference code is logged for information only.


C002 SCSI selection or reselection timeout occurred

Refer to the hosting partition for problem analysis.


C010 Undefined sense key returned by device

Refer to the hosting partition for problem analysis.


C020 Device internal configuration error

Refer to the hosting partition for problem analysis.


C100 SCSI bus command error occurred

Refer to the hosting partition for problem analysis.


C110 SCSI command timeout occurred

Refer to the hosting partition for problem analysis.


C210 Unexpected device condition recovered

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


C300 to C302 Media or device error occurred

Refer to the hosting partition for problem analysis.


C303 Media had an unknown format

No action required. This reference code is logged for information only.


C333 Incompatible media was detected

Perform the following:

  1. Verify that the disk has a format that is given support.
  2. If the format is given support, clean the disk and attempt the failing operation again.
  3. If the operation fails again with the same reference code, ask your media source for a replacement disk.

C400 Interface error detected by device

Refer to the hosting partition for problem analysis.


C402 Licensed Internal Code program error occurred

Ask your next level of support for assistance.

CFF2 Recovered from device not ready - Start Unit issued

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


CFF4 Internal device error occurred

Refer to the hosting partition for problem analysis.


CFF6 The device successfully recovered from a temporary error

No action is required. This reference code is logged for information only.


CFF7 Recovered device error

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


CFFE Recovered SCSI bus error

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


FF3D Recovered IOA error

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


FF6D Recovered System bus error

The device successfully recovered from a temporary error.

No action is required. This reference code is logged for information only.


Table 6. (632C) Optical storage unit failing items details

Failing Item Description Document Description
46G3532 CD-ROM device with tray Repair and Parts; removal and installation procedures
88G4918 CD-ROM device, Apex part Repair and Parts; removal and installation procedures
CDTRAY Flex cable on tray assembly See the service documentation for instructions.
DEVTERM Bus Terminator See the service documentation for instructions.
MEDIA Optical Media System operation information
PTFSRCH Licensed Internal Code See the service documentation for instructions.

Send feedback |  Rate this page