An optical storage unit failure occurred.
Perform the following:
Does the operation complete successfully?
Attempt the failing operation again with the original optical media to verify.
This ends the procedure.
For more on the Failing Item column entries, see Table 2. Optical storage unit failing items details, which follows the reference code table below.
Table 1. (6320, 6321, 6330, 6331, 6333, 6336, 6337) Optical storage unit reference codes
| Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
|---|---|---|
| C000 | System log entry only, no service action required
No action is required. This reference code is logged for information only. |
|
| C002 | SCSI selection or reselection timeout occurred | |
| C010 | Undefined sense key returned by device | |
| C020 | Device internal configuration error | |
| C100 | SCSI bus command error occurred | |
| C110 | SCSI command timeout occurred | |
| C210 | Unexpected device condition recovered
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| C300 | Media or device error occurred
Perform the following:
|
|
| C301 | Media or device error occurred
Dust check encountered. The optical media or the optical lens of the drive is dirty. Clean the optical drive and the media contained in the drive. |
|
| C302 | Media or device error occurred
The device encountered an 'out of spare sectors' condition when writing to the media. The media can no longer be written to but is still readable. Clean the optical drive and the media contained in the drive. |
|
| C303 | Media had an unknown format
No action required. This reference code is logged for information only. |
|
| C333 | Incompatible media was detected
Perform the following:
|
|
| C400 | Interface error detected by device | |
| C402 | Licensed Internal Code error
Ask your next level of support for assistance. |
|
| CFF2 | Recovered from device not ready - Start Unit issued
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| CFF4 | Internal device error occurred | |
| CFF6 | Device successfully recovered from a temporary error
No action is required. This reference code is logged for information only. |
|
| CFF7 | Recovered device error
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| CFFE | Recovered SCSI bus error
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| FF09 | Licensed Internal Code for optical device was not upgraded
This reference code is logged for information only. |
|
| FF3D | Recovered IOA error
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| FF6D | Recovered System bus error
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
Table 2. (6320, 6321, 6330, 6331, 6333, 6336, 6337) Optical storage unit failing items details
| Failing Item | Description | Document Description |
|---|---|---|
| 46G3532 | CD-ROM device with tray | Repair and Parts; removal and installation procedures |
| 88G4918 | CD-ROM device, Apex part | Repair and Parts; removal and installation procedures |
| CDTRAY | Flex cable on tray assembly | See the service documentation for instructions. |
| CNVTCRD | Converter card | See the service documentation for instructions. |
| DEVTERM | Bus Terminator | See the service documentation for instructions. |
| MEDIA | Optical Media | System operation information |
| STORIOA | Storage I/O adapter | See the service documentation for instructions. |
Table 3. (632B) Optical storage unit reference codes
| Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
|---|---|---|
| CFC1 | Virtual media list access problem
A virtual optical device cannot access the file containing the list of volumes. On this partition and the Network File System server, ensure the proper file is specified and proper authority is granted. |
|
| CFC2 | Error reading virtual volume list
A non-recoverable error was detected while reading the list of volumes. Check for errors on the Network File System server and resolve them. Then retry the operation. If the failure reoccurs, contact your hardware service provider. |
|
| CFC3 | Virtual media volume list is not valid
The data in the list of volumes is not valid. On the Network File System server, ensure that the proper file is specified, that all files are entered correctly, that there are no blank lines, and that the character set used is valid. |
|
| CFC4 | Virtual optical volume access problem
A virtual optical device cannot access the file containing the specified optical volume. On the Network File System server, ensure the proper file is specified in the list of volumes, and that the proper authority is granted. |
|
| CFC5 | Error reading virtual optical volume
A non-recoverable error was detected while reading a virtual optical volume. Check for errors on the Network File System server and resolve them. Then retry the operation. If the failure reoccurs, contact your hardware service provider. |
|
| CFC6 | Virtual optical volume is not valid
The file specified does not contain data that can be processed as a virtual optical volume. On the Network File System server, ensure all the files specified in the list of optical volumes are correct. |
|
| CFC7 | Virtual optical device detected error
A virtual optical device detected an error reported by the Network File System server that cannot be recovered. Check for errors on the Network File System server and resolve them. Then retry the operation. If the failure reoccurs, contact your hardware service provider. |
|
| CFC8 | Virtual optical device error
A virtual optical device encountered a non-recoverable error. Contact your next level of support for assistance. |
Table 4. (632B) Optical storage unit failing items details
| Failing Item | Description | Document Description |
|---|---|---|
| NEXTLVL | Call your next level of support for assistance | Call your next level of support for assistance |
| SVCDOCS | Customer engineer directed to system problem analysis | See the service documentation for instructions. |
Table 5. (632C) Optical storage unit reference codes
| Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
|---|---|---|
| C000 | System log entry only, no service action required
No action is required. This reference code is logged for information only. |
|
| C002 | SCSI selection or reselection timeout occurred
Refer to the hosting partition for problem analysis. |
|
| C010 | Undefined sense key returned by device
Refer to the hosting partition for problem analysis. |
|
| C020 | Device internal configuration error
Refer to the hosting partition for problem analysis. |
|
| C100 | SCSI bus command error occurred
Refer to the hosting partition for problem analysis. |
|
| C110 | SCSI command timeout occurred
Refer to the hosting partition for problem analysis. |
|
| C210 | Unexpected device condition recovered
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| C300 to C302 | Media or device error occurred
Refer to the hosting partition for problem analysis. |
|
| C303 | Media had an unknown format
No action required. This reference code is logged for information only. |
|
| C333 | Incompatible media was detected
Perform the following:
|
|
| C400 | Interface error detected by device
Refer to the hosting partition for problem analysis. |
|
| C402 | Licensed Internal Code program error occurred
Ask your next level of support for assistance. |
|
| CFF2 | Recovered from device not ready - Start Unit issued
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| CFF4 | Internal device error occurred
Refer to the hosting partition for problem analysis. |
|
| CFF6 | The device successfully recovered from a temporary error
No action is required. This reference code is logged for information only. |
|
| CFF7 | Recovered device error
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| CFFE | Recovered SCSI bus error
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| FF3D | Recovered IOA error
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
| FF6D | Recovered System bus error
The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. |
|
Table 6. (632C) Optical storage unit failing items details
| Failing Item | Description | Document Description |
|---|---|---|
| 46G3532 | CD-ROM device with tray | Repair and Parts; removal and installation procedures |
| 88G4918 | CD-ROM device, Apex part | Repair and Parts; removal and installation procedures |
| CDTRAY | Flex cable on tray assembly | See the service documentation for instructions. |
| DEVTERM | Bus Terminator | See the service documentation for instructions. |
| MEDIA | Optical Media | System operation information |
| PTFSRCH | Licensed Internal Code | See the service documentation for instructions. |