IBM Support

QMGTOOLS : Db2 for IBM i MustGather Data Collection

Troubleshooting


Problem

This is to help the collection of data for Db2 for IBM i functional issues.

Resolving The Problem

If QMGTOOLS is loaded on the system experiencing the error, do the following:

ADDLIBLE QMGTOOLS

GO MG

Select option 6 (Database menu) and hit enter, you will see the following menu options (with most recent build, 09/28/20 and later):

image 6401

 


Select the option that is the best match for your issue.
Be as specific as possible. 
Don't select general database when you're having a remote journal issue.

 

Usage Notes

These options are for working with the collected data in the /tmp/qmgdb/ directory

image 6402


All output is placed in directory /tmp/qmgdb/

If FTP output (FTPOUT) is *STDFTP (Standard FTP) or *BDFTP (for Blue Diamond customers), the collected data is zipped and sent to ECuRep (*STDFTP) or Blue Diamond server environment (*BDFTP). This will generate an update for the Case.

When data is collected, it is placed in /tmp/qmgdb/-Case number-

If Keep output (KEEPOUT) is *NO (N), the data is deleted.

If KEEPOUT(*YES) is specified the collected data is kept in the /tmp/qmgdb/-Case number- directory.
From there is can be removed or sent (FTPed) into ECuRep.

NOTE: If the /tmp/qmgdb/-Case number- directory already has collected data, and a new collection is taken using the same Case, the directory is cleared and new data written.