IBM Support

SI74329 - OSP-INCORROUT STRJW STRDW Check for incompatible libraries

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

OSP-INCORROUT STRJW STRDW Check for incompatible libraries


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
NONE



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.





APAR Error Description / Circumvention

-----------------------------------------------
STRJW and STRDW use the file level field in the run info file to
determine library compatibility.   The run info file for Job
Watcher is QAPYJWRUNI and the run info file for Disk Watcher is
QAPYDWRUNI. If the file level in the run info file differs from
the one for the current release, they will fail with a file
level error message. However, there are other library
incompatibilities that need to be identified.

CORRECTION FOR APAR SE74380 :
-----------------------------
With this PTF, STRJW and STRDW will compare record lengths of
every file in the target library with the record lengths of the
corresponding template files in QSYS.  If there are any
differences, an error message will be issued.

CIRCUMVENTION FOR APAR SE74380 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


Before applying or removing this PTF, end all Job Watcher and Disk
Watcher sessions and sign off from all jobs that were running them.

********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI64397 :
=================================================

Sign off and then sign back on to activate the changed programs.

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI52291 :
=================================================

After applying or removing this PTF, sign off and then back on to
activate the changed
service program.

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI68887 :
=================================================

Sign off and then sign back on to activate the changed service program.

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI56352 :
=================================================

If file QAPYDWTRC already exists in the library specified on the LIB
parameter of STRDW and previously collected data in file QAPYDWTRC in
that library is no longer needed, then delete file QAPYDWTRC from that
library prior to running STRDW.

If file QAPYDWTRC already exists in the library specified on the LIB
parameter of STRDW and previously collected data from file QAPYDWTRC in
that library is still needed, then there are two options:
1) Change the library specified on the LIB parameter of STRDW to one in
which the file QAPYDWTRC does not already exist.
2) Convert the old format of file QAPYDWTRC to the new version by doing
the following steps:
- RNMOBJ OBJ(TOLIB/QAPYDWTRC) OBJTYPE(*FILE) NEWOBJ(QAPYDWTRC1)
- CRTDUPOBJ OBJ(QAPYDWTRC) FROMLIB(QSYS) OBJTYPE(*FILE) TOLIB(TOLIB)
- CPYF FROMFILE(TOLIB/QAPYDWTRC1) TOFILE(TOLIB/QAPYDWTRC)
FROMMBR(*ALL) TOMBR(*FROMMBR) MBROPT(*REPLACE) FMTOPT(*MAP)
- DLTF FILE(TOLIB/QAPYDWTRC1)


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI70658      OSP-INCORROUT Job Watcher SQL Collection Improvements
   SI66984      OSP-INCORROUT Job Watcher SQL data collection
   SI66984      OSP-UNPRED Job Watcher uses excessive temporary storage
   SI65003      OSP-INCORROUT ADDJWDFN Job Watcher definition is incorrect
   SI64397      OSP-MSGCPF2469 Job Watcher error sending message to QHST
   SI62920      OSP-INCORROUT Job Watcher file QAPYJWSTK, field STACK
   SI57747      OSP-INCORROUT Job Watcher SQL Host Variables are 0
   SI52291      OSP-INCORROUT Job Watcher SQL Host Variables are incorrect
   SI68887      OSP-UNPRED Disk Watcher consumes excessive temporary storage
   SI57981      OSP-MSGCPF5009 Disk Watcher QAPMCCCNTB duplicate record keys
   SI56352      OSP-INCORROUT Add Disk Watcher task count in BINCHAR(8) form
   SI56264      OSP-INCORROUT Add Disk Watcher task count in CHAR(8) format

Summary Information

System..............................i
Models..............................
Release.............................V7R2M0
Licensed Program...............5770SS1
APAR Fixed..........................View details for APAR SE74380
Superseded by:......................
Recompile...........................N
Library.............................QSYS
MRI Feature ........................NONE
Cum Level...........................C1084720


IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2","Product":{"code":"SG15V","label":"PTF Cover Letters - IBM i General"},"Component":"5770SS1","Edition":""},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2","Product":{"code":"SG16F","label":"PTF Cover Letters - IBM i 7.2"},"Component":"5770SS1","Edition":""}]

Document Information

Modified date:
18 April 2021