IBM Support

SI70357 - OSP-OTHER-F/QHACMN-RC1-MSGCPDBB01 MSGCPDBB01 ENCOUNTERED DUR

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

OSP-OTHER-F/QHACMN-RC1-MSGCPDBB01 MSGCPDBB01 ENCOUNTERED DUR


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
NONE



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.





APAR Error Description / Circumvention

-----------------------------------------------
Start of admin domain causing the admin domain CRG job encounter
MSGCPDBB01.

This APAR will result in a PTF for additional data capture to
help determine root cause.

CORRECTION FOR APAR SE70912 :
-----------------------------
Additional logging information is added.

CIRCUMVENTION FOR APAR SE70912 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


1. On each node in the cluster, end clustering, apply the fix, and then
start clustering.  It is not necessary to update all nodes at the same
time, however, any node without the fix will continue to be a potential
source of the problem.

2. It is recommended to sign off or end any user job that issued any
cluster command or API. After the fix is applied, the job can be
started or can sign on again.

3. After the PTF has been applied, you should also restart the
QPRFSYNCH job on every node in your cluster.  You can restart the
QPRFSYNCH job with the following commands:

CALL PGM(QSYS/QFPAPRFJ) PARM(END)
CALL PGM(QSYS/QFPAPRFJ) PARM(START)


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI70276      OSP-OTHER-F/STRINGHIGHUSE4K-T/QCSTADCMN-MSGMCH0601 MSGMCH060
   SI70045      HASM-HA-F/CSTADCHGS-T/CSTADCHGS-MSGCPF1059 QAUDLVL SET WITH
   SI70047      Remove support for *TRNLIN resource type and obsolete *ETHLI
   SI69699      Cluster related fixes for 7.4
   SI69372      Cluster related fixes for 7.4

Summary Information

System..............................i
Models..............................
Release.............................V7R4M0
Licensed Program...............5770SS1
APAR Fixed..........................View details for APAR SE70912
Superseded by:......................View fix details for PTF SI75925
Recompile...........................N
Library.............................QSYS
MRI Feature ........................NONE
Cum Level...........................C9304740


IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.4","Product":{"code":"SG15V","label":"PTF Cover Letters - IBM i General"},"Component":"5770SS1","Edition":""},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.4","Product":{"code":"SS9QQS","label":"IBM i 7.4"},"Component":"5770SS1","Edition":""}]

Document Information

Modified date:
15 April 2021