IBM Support

SI65729 - OSP-DB-OTHER-INCORROUT SERVER MODE CLI JOB SET TO LOGOUTPUT(

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

OSP-DB-OTHER-INCORROUT SERVER MODE CLI JOB SET TO LOGOUTPUT(


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
NONE



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.





APAR Error Description / Circumvention

-----------------------------------------------
Server mode CLI jobs, QSQSRVR, are producing a job log when they
end even though the job description is set for *PND. The problem
appears to be that the QSQSRVR job itself is printing the job
log. There is a data area, NOCLILOG, which is set to also
prevent these log from being created but it has no effect.

See APAR SE49688 for more details on this data area. To create
the data area, use the command:
CRTDTAARA DTAARA(QSYS/NOCLILOG) TYPE(*CHAR) LEN(1)

CORRECTION FOR APAR SE67943 :
-----------------------------
Code will be enhanced to allow user to request the QSQSRVR
joblogs to not get produced when the job ends unexpectedly, for
example due to a ENDSBS command.  Normally, a joblog is produced
to find the root cause of the catastrophic errors in the QSQSRVR
jobs.  To request that the joblog not be produced, both of the
below settings need to be set.
The JOBD used by the QSQSRVR jobs needs to be set to
LOGOUTPUT(*PND)  and
the CLI dataarea needs to exist on the system. This can be
created with the following command
CRTDTAARA DTAARA(QSYS/NOCLILOG) TYPE(*CHAR) LEN(1)

CIRCUMVENTION FOR APAR SE67943 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


None.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI56183      OSP-DB-OTHER-T/QQQSVDBG-MSGSQL0952
   SI55718      OSP-DB-OTHER-UNPRED EXCESSIVE QSQSVCDMP SPOOLED FILES CREATE
   SI53611      OSP-DB-OTHER-UNPRED SERVICEABILITY CHANGE

Summary Information

System..............................i
Models..............................
Release.............................V7R2M0
Licensed Program...............5770SS1
APAR Fixed..........................View details for APAR SE67943
Superseded by:......................
Recompile...........................N
Library.............................QSYS
MRI Feature ........................NONE
Cum Level...........................C8032720


System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15V","label":"PTF Cover Letters - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG16F","label":"PTF Cover Letters - IBM i 7.2 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
25 October 2017