Abstract

OSP-WAIT RESTORE OF IFS HANGS


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
NONE



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.





APAR Error Description / Circumvention

-----------------------------------------------
Restore of IFS hangs at 99,500 objects.
Secondary Thread call stack:
ISF=F5330F477CFFF0C0 NIA=FFFFFFFFFE234060 MODULE
RMPRLONGWAITRCVTREEQUEUE+0X940
ISF=F5330F477CFFF220 NIA=FFFFFFFFFE1A275C MODULE
QMDEQMIQUEUE+0XC8C
ISF=F5330F477CFFF960 NIA=FFFFFFFFFF0050E8 MODULE #CFMIR+0XE8
ISF=F5330F477CFFFA20 NIA=FFFFFFFFFF094608 MODULE CFSCV0A+0X158
ISF=DCC0F419C7FFFB80 NIA=0DD0F5C5DB036EB0 SRVPGM
QSYS/QSRLIBS1-QSRS1THR:QSRWAITFOREVERFORGROUPTOWORKON__FV+0X70
STMT# 8
ISF=DCC0F419C7FFFC80 NIA=365BB2B3CF0A6DB0 SRVPGM
QSYS/QSRGENSE-QSRTHREA:QSRRSTWORKERTHREAD__FP19QSRWORKERTHREADDA
TA+0X170 STMT# 1
ISF=DCC0F419C7FFFDC0 NIA=273491AF75006AEC SRVPGM
QSYS/QLESPI-QLECRTTH:LE_CREATE_THREAD2__FP12CRTTH_PARM_T+0X18C
STMT# 19
ISF=DCC0F419C7FFFEE0 NIA=FFFFFFFFFFFF81D0 MODULE #CFCBLAT+0X1D0
ISF=F5330F477CFFFA80 NIA=FFFFFFFFFE1F6388 MODULE
AIUPCALLPORTALMACH+0XE8
ISF=F5330F477CFFFCC0 NIA=FFFFFFFFC165A96C MODULE
PMINITIATETHREAD+0X2B4C
ISF=F5330F477CFFFF20 NIA=0000000000000000 NOT VALID INSTRUCTION
ADDRESS

During the hang condition entries similar to the following will
repeat in the SR flight recorder for the group being processed:

qsrRST: qsrPrioritizeWork - Group xxxx waiting to load
additional descriptor spaces

CORRECTION FOR APAR SE62779 :
-----------------------------
This hang condition is specific to parallel restores of IFS
objects when using less drives than that which were used for the
parallel save. Changes will be made to correct the restore hang.

CIRCUMVENTION FOR APAR SE62779 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


None.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI54971      OSP-OTHER-MSGCPF3710 CPF3710 LOGGED WHEN IFS DATA IS RESTORE

Summary Information

System..............................i
Models..............................
Release.............................V7R2M0
Licensed Program...............5770SS1
APAR Fixed..........................View details for APAR SE62779
Superseded by:......................View fix details for PTF SI68092
Recompile...........................N
Library.............................QSYS
MRI Feature ........................NONE
Cum Level...........................C6127720


System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15V","label":"PTF Cover Letters - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
27 October 2015