IBM Support

SI44354 - RDARS-ONDCSRV-INCORROUT RETRIEVING SPOOLED FILE INTO GRAPHIC

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

RDARS-ONDCSRV-INCORROUT RETRIEVING SPOOLED FILE INTO GRAPHIC


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED      PTF/FIX  LEVEL

TYPE PROGRAM  REL  NUMBER   MIN/MAX  OPTION
---- -------- ---  -------  -------  ------
NONE



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.





APAR Error Description / Circumvention

-----------------------------------------------
When a user retrieves a spooled file into the graphical markup
tool or wizard, there is a copy of the splf produced by
PRTTXTOND and that copy goes into /tmp directory. If the user
does not have *ALLOBJ special authority that object is not
removed from /tmp so that the next time that user tries to
retrieve the same splf to continue working on the markup - they
get an error - EROND0201PRTTXTOND command ended in error.

CORRECTION FOR APAR SE49007 :
-----------------------------
PRTTXTOND and the graphical indexer function of the OnDemand
Administrator client have been modified to correctly delete any
new temporary files they create. Temporary files created in the
/tmp directory in IFS with naming convention of
"CA.jobname.username.jobnumber.splfname.splfnumber" that were
created before the application of this PTF should be deleted
manually by a user with *ALLOBJ authority by using the RMVLNK
command or option 6=Remove from the WRKLNK command.

The ownership of program QRLCCRTDTQ is now assigned to
QRDARS400.

CIRCUMVENTION FOR APAR SE49007 :
--------------------------------
Perform Administrative graphical markup functions using a user
profile with *ALLOBJ authority.


DESCRIPTION OF PROBLEM FIXED FOR APAR SE49168 :
-----------------------------------------------
Spool files with very large afp resources fail to load to
OnDemand returning MCH0603 error.

If in-lined resources are greater than 16MB an internal error
occurs.

CORRECTION FOR APAR SE49168 :
-----------------------------
If the in-lined resources are greater the 32MB the load fails.
This is now fixed.

Internal problem is fixed.

CIRCUMVENTION FOR APAR SE49168 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI35730 :
=================================================

After applying this PTF, GROUP and RECORDRANGE triggers numbers 2 - n
will be directly based off trigger 1.  This is how the graphical markup
tool handles them.  What does this mean?  It means trigger 1 must be
found on a page for GROUP or RECORDRANGE triggers to be found on that
page.   Previously if trigger 1 had been found in the document then
GROUP and RECORDRANGE triggers would be found on any page.

There is a very small possibility that this will affect how some
reports are indexed.  If you are using a GROUP or RECORDRANGE trigger
that was being found on a page that did not have trigger 1 found on it
you now should use a FLOAT trigger to find that value.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI43830      RDARS-ONDCSRV-INCORROUT SOME AFPDS DOCUMENTS, WHEN ARCHIVED,
   SI42212      RDARS-ONDCSRV-MSGMCH0603 SOME SPOOL FILES FAIL TO ARCHIVE -
   SI42212      RDARS-ONDCSRV PRTTXTOND AND RETRIEVE OF SPLF INTO WIZARD GIV
   SI42212      RDARS-ONDCSRV-UNPRED ALLOW FOR LARGER RESOURCES TO BE HANDLE
   SI42212      RDARS-ONDCSRV-INCORROUT LAST PAGE OF AFP SPLF NOT DISPLAYED
   SI40478      RDARS-ONDCSRV-INCORROUT OD ARCHIVE FAILS WITH MSGOND2050 IF
   SI40334      RDARS-ONDCSRV-UNPRED ISSUE MESSAGE IF NO STORAGE SET IS ASSI
   SI36809      RDARS-ONDCSRV-T/QRLMIDX-MSGCPFA089
   SI36809      RDARS-ONDCSRV-UNPRED INDEXER COMPATIBILITY CHANGES
   SI35730      RDARS-ONDCSRV-INCORROUT SOME AFP REPORTS ARE ARCHIVED INTO C
   SI35730      RDARS-ONDCSRV-T/QRLMGSD-MSGMCH0603 when archiving AFP Spool
   SI35730      RDARS-ONDCSRV-UNPRED UPDATE INDEXER
   SI35730      RDARS-ONDCSRV-INCORROUT RECORD RANGE TRIGGER FOUND IN ERROR

Summary Information

System..............................i
Models..............................
Release.............................V7R1M0
Licensed Program...............5770RD1
APAR Fixed..........................View details for APAR SE49007
View details for APAR SE49168
Superseded by:......................View fix details for PTF SI66705
Recompile...........................N
Library.............................QRDARS
MRI Feature ........................NONE
Cum Level...........................C2115710


System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.1.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15V","label":"PTF Cover Letters - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
31 August 2011