IBM Support

MF68823 - LIC-OTHER-WAIT VARY ON OF FLASHCOPY TARGET IASP SITS IN JOUR

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

LIC-OTHER-WAIT VARY ON OF FLASHCOPY TARGET IASP SITS IN JOUR


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
PRE  5770999  V7R3M0    MF66876   00/00    0000



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the 'IBM License Agreement for Machine
Code', the terms of which were provided in a printed document that was
delivered with the machine.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.





APAR Error Description / Circumvention

-----------------------------------------------
IASP vary on or IPL is stuck in the Journal Recovery step,
SRCC6004056.

CORRECTION FOR APAR MA49115 :
-----------------------------
A field in a journal receiver was not being written to disk and
could be stale as a result of a FlashCopy or system outage where
memory is not preserved. This can cause the Journal Recovery
step of IPL or IASP vary on to not complete successfully.

This is only an issue when files with LOBs (Large Objects) are
being journaled. The fix resolves the issue by writing the field
to disk as needed.

CIRCUMVENTION FOR APAR MA49115 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


None.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   MF68175      LIC-DB-JRN-WAIT SYSTEM HANG WHILE SAVING AUDIT RECEIVERS
   MF67859      OSP-DB-JRN-PERFM Long JBw waits in Journal
   MF67353      OSP-DB-JRN-RC3-MSGCPF7091 MSGCPF7091 RC3 VL04030041 VL030002
   MF66851      OSP-DB-JRN FILTERED REMOTE JOURNAL HANGS IN *ASYNCPEND
   MF65313      LIC-JRN New Journal System Sequence Number implementation
   MF64159      OSP-OTHER-PERFM JO-EVALUATE TASK IS CONSUMING CPU WHILE LITT
   MF63549      OSP-OTHER-MSGCPFA0D4 VARY ON OF IASP CAUSES MANY IFS VLOGS A
   MF62747      OSP-JRN-MSGCPF70D5RC3 FILTERED REMOTE JOURNAL ENDS WITH CPF7
   MF62257      OSP-DB-JRN Degraded performance due to increased IO and gate
   MF62040      LIC-DB-JRN-RC2-MSGCPF7091 CPF7091 RC2 NO JOURNAL MENTIONED
   MF61626      LIC-DB-JRN Long journal sync IASP vary on C600 4058
   MF61654      LIC-OTHER-WAIT GATE WAIT WHILE COMMITTING MORE THAN 32K TRAN
   MF62940      LIC-DB-JRN-PERFM QDBSRV JOBS RUNNING CONSTRAINT ENFORCEMENT
   MF66633      OSP-DB-JRN-F/QJODSPJA-T/QJODSPJA-MSGMCH1210 FOR CASCADE REMO
   MF63127      OSP-JRN-MSGMCH3203 F/#JOFINDA T/QJODSPJE DSPJRN on remote jo
   MF63062      OSP-JRN-MSGMCH3203 F/#JOFINDA T/QJORCVJE for a filtered remo

Summary Information

System..............................  i
Models..............................  
Release.............................  V7R3M0
Licensed Program....................  5770999
APAR Fixed..........................  View details for APAR MA49115
Superseded by:......................  
Recompile...........................  N
Library.............................  QSYS
MRI Feature ........................  NONE
Cum Level...........................  C2132730


IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0","Product":{"code":"SWG60","label":"IBM i"},"Component":"5770999","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date:
24 May 2022