PTF Cover Letter
PTF ( Program Temporary Fixes ) Cover letter
LIC-MEDIA-TAPE Improved Diagnostics
Pre/Co-Requisite PTF / Fix List
REQ LICENSED PTF/FIX LEVEL
TYPE PROGRAM RELEASE NUMBER MIN/MAX OPTION
---- -------- --------- ------- ------- ------
PRE 5770999 V7R2M0 MF59075 00/00 0000
CO 5770999 V7R2M0 MF65109 00/00 0000
CO 5770999 V7R2M0 MF63917 00/00 0000
CO 5770999 V7R2M0 MF61618 00/00 0000
CO 5770999 V7R2M0 MF60595 00/00 0000
NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels. This PTF may be a prerequisite
for future PTFs. By applying this PTF you authorize and agree to the
foregoing.
This PTF is subject to the terms of the 'IBM License Agreement for Machine
Code', the terms of which were provided in a printed document that was
delivered with the machine.
SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.
APAR Error Description / Circumvention
-----------------------------------------------
Additional advanced analysis macro changes are needed.
CORRECTION FOR APAR MA47155 :
-----------------------------
Minor advanced analysis macros changes have been made.
CIRCUMVENTION FOR APAR MA47155 :
--------------------------------
None.
Activation Instructions
None.
Special Instructions
********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************
SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF MF65029 :
=================================================
Use the following steps to set the preferred path using the iotapepaths
Advanced analysis macro:
1. From the Use Dedicated Service Tools or System Service
Tools display, select Start a Service Tool.
2. From the Start a Service Tool display, select
Display/Alter/Dump.
3. From the Display/Alter/Dump Output Device display, select
Display/Alter storage.
4. From the Select Data display, select Licensed Internal
Code (LIC) data.
5. From the Select LIC data display, page down and select
Advanced analysis
6. From the Select Advanced Analysis Command, type a 1 in
the option field next to the blank line and enter
iotapepaths as the command.
7. From the Specify Advanced Analysis Options display enter
the tape device resource name associated with the
preferred path you want to set, followed by the parameter
-PREFER to change the preferred path.
Example:
Specify Advanced Analysis Options
Output device . . . . . . : Display
Type options, press Enter.
Command . . . . : IOTAPEPATHS
Options . . . . . tap02 -PREFER
SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF MF60425 :
=================================================
iotapepaths advanced analysis macro:
The first input parameter is a hardware resource name, one of
1. Blank Report all tape resources
2. IOP name Report tape resources configured on this IOP
3. TapeLibrary Report tape resources associated with this
logical tape library
4. TapeDevice Report all the paths to the resource
Additional keywords may be specified:
-NOHEAD Omit the title line from the output
-VIEW sort Specify how the output is sorted, where sort is:
LIBRARY Report drives under controlling library
DEVICE Report all paths to a drive when the first one
is encountered in the report output.
Output format:
Columns Title Meaning
1-10 RSC_NAME__ Hardware Resource Name reported
12-19 CCIN-MOD Device type and model
21-35 SERIAL_________ Device serial number
37-40 PATH Tape device path number
42-51 LIBRARY___ Tape library if device is in a library
53-54 CP Number of control paths
56-65 IOP_______ controlling IOP resource name
67-70 PORT IOP port the device is attached to
71-87 STATUS__________ Description of device status
89-104 WWID____________ Device world wide ID
106-113 LEVEL___ Firmware level active in the device
Default Instructions
THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.
Supersedes
PTF/FIX NO(S). APAR TITLE LINE
-------------- ------------------------------------------------------------
MF63923 LIC-MEDIA-TAPE Improved Diagnostics
MF62949 LIC-MEDIA-TAPE Improved Diagnostics
MF61620 LIC-MEDIA-TAPE Diagnostic Improvements
MF61407 LIC-MEDIA-TAPE MULTIPATH IMPROVEMENTS
MF60800 LIC-MEDIA-TAPE Diagnostic Improvements
MF60594 LIC-MEDIA-TAPE Diagnostic Improvements
MF60202 LIC-MEDIA-TAPE Diagnostic Improvements
MF60028 LIC-MEDIA-TAPE Prepare for future function
MF59384 LIC-MEDIA-TAPE Prepare for future function
MF58079 LIC-MEDIA-TAPE Diagnostic Improvements
MF65029 LIC-MEDIA-TAPE SET PREFERRED PATH
MF60894 LIC-MEDIA-TAPE iotapepaths macro output has duplicate librar
MF60425 LIC-MEDIA-TAPE Advanced Analysis Tape Path Report
Summary Information
System.............................. | i |
Models.............................. | |
Release............................. | V7R2M0 |
Licensed Program............... | 5770999 |
APAR Fixed.......................... | View details for APAR MA47155 |
Superseded by:...................... | View fix details for PTF MF68141 |
Recompile........................... | N |
Library............................. | QSYS |
MRI Feature ........................ | NONE |
Cum Level........................... | C9123720 |
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.
Was this topic helpful?
Document Information
Modified date:
22 November 2020