MF65030 - LIC-MEDIA-TAPE SET PREFERRED PATH

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

LIC-MEDIA-TAPE SET PREFERRED PATH


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
NONE



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the 'IBM License Agreement for Machine
Code', the terms of which were provided in a printed document that was
delivered with the machine.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.


APAR Error Description / Circumvention

-------------------------------------------------
Hardware Service Manager does not provide an interface for
changing the preferred path device for a tape device used by a
pure virtual partition.

CORRECTION FOR APAR 'MA47105' :
-------------------------------
This PTF adds an option to the ioptapepaths advanced analysis
macro to allow the preferred path to be set/changed.

Use the following steps to set the preferred path using the
iotapepaths Advanced analysis macro:

1. From the Use Dedicated Service Tools or System Service
Tools display, select Start a Service Tool.
2. From the Start a Service Tool display, select
Display/Alter/Dump.
3. From the Display/Alter/Dump Output Device display, select
Display/Alter storage.
4. From the Select Data display, select Licensed Internal
Code (LIC) data.
5. From the Select LIC data display, page down and select
Advanced analysis
6. From the Select Advanced Analysis Command, type a 1 in
the option field next to the blank line and enter
iotapepaths as the command.
7. From the Specify Advanced Analysis Options display enter
the tape device resource name associated with the
preferred path you want to set, followed by the parameter
-PREFER to change the preferred path.

Example:
Specify Advanced Analysis Options



Output device  . . . . . . :   Display



Type options, press Enter.



Command . . . . :   IOTAPEPATHS



Options . . . . .   tap02 -PREFER




CIRCUMVENTION FOR APAR 'MA47105' :
----------------------------------
None.


Activation Instructions

None.




Special Instructions

This PTF adds an option to the ioptapepaths advanced analysis
macro to allow the preferred path to be set/changed.

Use the following steps to set the preferred path using the
iotapepaths Advanced analysis macro:

1. From the Use Dedicated Service Tools or System Service
Tools display, select Start a Service Tool.
2. From the Start a Service Tool display, select
Display/Alter/Dump.
3. From the Display/Alter/Dump Output Device display, select
Display/Alter storage.
4. From the Select Data display, select Licensed Internal
Code (LIC) data.
5. From the Select LIC data display, page down and select
Advanced analysis
6. From the Select Advanced Analysis Command, type a 1 in
the option field next to the blank line and enter
iotapepaths as the command.
7. From the Specify Advanced Analysis Options display enter
the tape device resource name associated with the
preferred path you want to set, followed by the parameter
-PREFER to change the preferred path.

Example:
Specify Advanced Analysis Options



Output device  . . . . . . :   Display



Type options, press Enter.



Command . . . . :   IOTAPEPATHS



Options . . . . .   tap02 -PREFER


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   MF60926      LIC-MEDIA-TAPE iotapepaths macro output has duplicate librar

Summary Information

System..............................i
Models..............................
Release.............................V7R3M0
Licensed Program...............5770999
APAR Fixed..........................View details for APAR MA47105
Superseded by:......................View fix details for PTF MF68142
Recompile...........................N
Library.............................QSYS
MRI Feature ........................NONE
Cum Level...........................C9116730


IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3","Product":{"code":"SG15V","label":"PTF Cover Letters - OS\/400 General"},"Component":"5770999","Edition":""}]