Product Documentation
Abstract
IBM System x3400 M2, x3500 M2 - Fan Cage Assembly installation movie
Content
Text from the audio portion of the Fan Cage Assembly installation movie
To install the Fan Cage Assembly:
Note: Before installing the Fan Cage assembly insure that all cables are routed correctly in there retainers.
- Place the fan-cage assembly into the server, using the guides on the fan cage and the release latches for alignment and press in until latched in place.
-
Install the Air Baffle
- Place the air baffle into the server using the positioning pins on the air baffle and the locating holes in the server and fan-cage assembly for alignment, and then press down until latched in place.
- Press the locking tab to release the power supply cage and then rotate the cage into the server and lower the handle.
Here is a closer look at a positioning pin on the baffle and a hole in the fan cage assembly.
Note: use care to ensure that the power cables are routed so they are not pinched when closing the cage.
Improper routing, as shown, here will cause damage to the cables.
- Return the server to its normal operating position.
-
Install the Hot-swap Power Supplies:
- Slide the Power Supply into the bay until secured by the latch.
- Use the same procedure to install the second power supply if required.
- Connect the power cord to the power supply.
-
Install the side Cover:
- Position the channel on the cover over the rail on the bottom edge of the chassis.
- Rotate the cover toward the chassis and then press down on the cover release latch and close the cover.
- Lock the side cover if required.
For specific instructions for the removal and installation of hardware.
- Problem Determination and Service Guide - IBM System x3400 M2
- Problem Determination and Service Guide - IBM System x3500 M2
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03XIC","label":"System x->System x3400 M2->7836"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU03XIF","label":"System x->System x3400 M2->7837"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03XIH","label":"System x->System x3500 M2->7839"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Was this topic helpful?
Document Information
Modified date:
24 January 2019
UID