To remove the DIMM air duct:
Remove the Left-side Cover:
- Unlock the side cover and press the cover-release latch down while rotating the top edge of the cover away from the server; then, lift the cover off the server and set it aside.
Remove the Bezel:
- Release the three tabs on the left edge of the bezel and rotate the bezel away from the server; then, pull the bezel away from the server.
Here's a closer look at a latching tab.
- Place the system on its right side this is the recommended service position.
Remove the Power Supplies:
- Press the locking latch on the power supply and pull the power supply out of the bay.
- Use the same procedure to remove Power Supply 2, if installed.
- Lift the Power supply cage handle and Rotate the Cage out of the chassis until it latches in the open position.
Here's a closer look at the cage latch action.
Remove the DIMM Air Duct:
- Remove the two screws securing the duct to the cage.
- Push the air duct up toward the rear of the cage.
- Once the locator pins are free of the cage, lift the duct from the server.