Content

To install the ServeRAID Controller:

  1. Ensure that the retention latches are open
  2. Insert the ServeRAID Controller straight into the slot, pressing on both corners of the controller at the same time until secured by the latches.

Install Riser Card Assembly 1:

  1. Position the Riser Card Assembly over the socket, gently press down to seat. Insure that the tab on the rear of the assembly is fully seated into the slot in the chassis.

Install the Top Cover:

  1. Position the cover over the chassis aligning the tabs in the cover with the slots in the chassis.
  2. Slide the cover forward and secure with the single captive screw.
  3. Rotate the fan door to the closed and latched position.
For specific instructions for the removal and installation of hardware.

 

Document Location

Worldwide

Operating System

System x:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU02DKY","label":"System x->System x3550->1913"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU02QYU","label":"System x->System x3550->1013"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QUOEF4I","label":"System x->System x3550->7978"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]