To remove the Control Panel
Remove the Side Cover:
-
Turn off the server and all peripheral devices, and disconnect all power cords and external cables.
-
Place the system on its right side. This is the recommended Service Position.
-
Remove the two thumbscrews on the rear of the server. Slide the cover to the rear approximately one half inch and lift it off the server.
Remove the Bezel:
-
Press down on the bezel release tab to disengage the bezel from the chassis. Rotate it open to free the hinge tabs and lift it off.
Remove the Control Panel:
-
Disconnect the SATA Drive power cable from the drive.
Note: If two drives are installed, disconnect the cables from both drives. -
Remove the thumbscrew securing the drive cage. Rotate the drive cage to latch it in the open position.
-
Disconnect the front panel and USB cables from the system board.
-
Release the cables from the cable retainer. Note: The front air baffle has been removed for better visibility.
-
Remove the single screw.
Note: Placing a small spacer under the system will make access to the screw easier. -
Grasp the bottom of the panel and rotate it up and off the server, then carefully pull the cables out through the hole in the chassis.
-
Disconnect the USB and control panel cables from the card.