Product Documentation
Abstract
IBM System x3105 - Optical drive removal movie
Content
Text from the audio portion of the optical drive removal movie
To remove a Drive from Bay 1 or 2
Remove the Side Cover:
-
Turn off the server and all peripheral devices, and disconnect all power cords and external cables.
-
Place the system on its right side. This is the recommended Service Position.
-
Remove the two thumbscrews on the rear of the server. Slide the cover to the rear approximately one half inch and lift it off the server.
Remove the Optical Drive:
-
Disconnect the signal and power cables from the drive.
-
Press the blue latch to release the drive, then push the drive from the rear, then grasp it and pull it from the bay.
-
Lift the drive retainer clip from the drive and set it aside.
For specific instructions for the removal and installation of hardware.
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW328","label":"System x->System x3105"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB26","label":"Storage"}}]