Fix Readme
Abstract
These are the release notes for the 4.1.2.00 VIOS fix pack release.
Content
VIOS 4.1.2.00 Release Notes
Package Information
PACKAGE: Update Release 4.1.2.00
IOSLEVEL: 4.1.2.00
VIOS level is | The AIX level of the NIM Master level must be equal to or higher than |
Update Release 4.1.2.00 | AIX 7300-04 |
General package notes
Be sure to heed all minimum space requirements before installing.
Review the list of fixes included in Update Release 4.1.2.00
To take full advantage of all the functions available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 4.1.2.00.
Microcode or system firmware downloads for Power Systems
If the VIOS being updated has filesets installed from the VIOS Expansion Pack, be sure to update those filesets with the latest VIOS Expansion Pack if updates are available.
Update Release 4.1.2.00 updates your VIOS partition to ioslevel 4.1.2.00. To determine if Update Release 4.1.2.00 is already installed, run the following command from the VIOS command line.
$ ioslevel
If Update Release 4.1.2.00 is installed, the command output is 4.1.2.00.
Upgrade to VIOS 4.1.x
Existing VIOS systems with supported versions of 3.1.x.y can be upgraded to VIOS version 4.1.2.00 (DVD image) or 4.1.2.00 (Flash image) using viosupgrade tool. Although it is recommended to be on VIOS 3.1.4.30 or later SP level before upgrading to VIOS 4.1.x level.
VIOS systems with SSP configuration must be on 3.1.3.x or later level before upgrading to 4.1.x level or adding 4.1.x nodes into cluster.
If Active Memory Sharing (AMS) is configured on the VIOS, it should be un-configured before upgrading. You may refer the link on how to un-configure.
Before upgrading, you may read the viosupgrade blog in PowerVM Community which explains various scenarios.
Note 1: In an SSP cluster environment, if you're upgrading from version 3.1.4.50 or later, you must upgrade only to version 4.1.1.00 or later. Additionally, ensure that all nodes in the cluster are running version 3.1.4.50 or later before proceeding with the upgrade.
Note 2: When upgrading a VIOS from version 4.1.1.00 or later to 4.1.2.00 using the viosupgrade method you may encounter a boot issue while booting with the new rootvg disk, if it gets into incorrect combination of attributes reserve_policy and algorithm. Run below command on the SCSI disks to avoid the problem.
$ chdev -dev hdiskX -attr reserve_policy=single_path algorithm=fail_over
For Customers using NVMe Over Fabric (SAN) as their Boot Disk
Booting from NVMeoF disk may fail if certain fabric errors are returned, hence a boot disk set up with multiple paths is recommended. In case there is a failure to boot, the boot process may continue if you exit from the SMS menu. Another potential workaround is to discover boot LUNs from the SMS menu and then retry boot.
Note
If the Virtual I/O servers are configured with “32Gb PCIe4 2-Port FC Adapter, Feature Code(s) EN1J and EN1K”, then the requirement is to update the adapter microcode level to 7710812214105106.070120 before updating the Virtual I/O server to 4.1.2.00 level.
Please refer to the release notes at this link
HIPER issue: If you are upgrading to VIOS 3.1.4.50 or 4.1.1.x or above version please consult this link
4.1.2.00 New Features
This release of VIOS contains several enhancements in PowerVM virtualization area.
Live Partition Mobility (LPM) enhancements
You can bypass the port-level validation for the N_Port ID Virtualization (NPIV) devices for logical partition (lpar) migration with Linux or IBM i operating systems. This action successfully completes the LPM operation if all the Logical Unit Numbers (LUN) are available across both the source and destination VIOS instances, irrespective of the storage ports through which they are accessible.
For more information, see Specifying the attributes for a partition mobility operation by using the VIOS.
VIOS command enhancements
The following enhancements are made to the commands:
The fcstat command displays the I/O latency statistics across multiple layers like Storage Area Network (SAN) and fiber channel adapter. For virtual AIX® clients, you can also view additional statistics for VIOS, hypervisor and client Virtual Fibre Channel (VFC) adapter layers.
The updateios command uses alternate disks to install new updates and retain the current state of the rootvg disk. When you run the updateios command, the current rootvg disks are cloned to the alternate disks and perform the new installation process. You can use the -altdisk option to provide values of one or more alternate disks, separated by a colon.
The following AIX commands can be accessed in VIOS through the Role Based Access Control (RBAC) security functionality:
The viosecure command permits or denies firewall rules for an entire subnet range along with the IP address.
The lsmap command filters NPIV device mappings based on the partition name and operating system type. Use the -cpname and -cpos options along with the -npiv option to display the relevant device mappings.
The RBAC- enabled AIX pvi command in VIOS lets you view and modify restricted system configuration files, such as /etc/syslog.conf through the following steps:
Run the setsecattr command to add vios.file.read or vios.file.write authorizations to the required system configuration file.
Example:
setsecattr -f writeauths=vios.file.write /etc/cronlog.conf
Run the setkst command to apply the authorization changes to the system configuration file.
Run the pvi command to access and edit the system configuration file.
Virtual Fibre Channel (VFC) adapter enhancements
The following enhancements are made to the VFC adapters:
The Quality of Service (QoS) feature in VIOS is a technological preview for the VFC stack. It enables you to manage and prioritize storage traffic between a virtual machine (VM) and a Fibre Channel (FC) storage area network (SAN) by setting performance limits on VFC host adapters.
During critical events, VIOS automatically sends notifications to client lpars so that the lpars can take action on these critical events. This rectification action reduces the disruption or delay in the I/O processing activity if other unaffected VFC paths are available. These critical events may occur due to the following disruptive operations:
Firmware (microcode) updates
Extended Enhanced Error Handling (EEH) events
Live dump operations
For more information, see the latest AIX and IBM i documentation.
Shared Storage Pool (SSP) enhancements
The following enhancements are made to the shared storage pool:
When the VIOS nodes in an SSP cluster is upgraded to VIOS version 4.1.2.00 or later, the Node Upgrade Status of the nodes changes to the UP_LEVEL state. After all the nodes are upgraded to the 4.1.2.00 level, the rolling upgrade process starts automatically and the Node Upgrade Status level changes to the ON_LEVEL state.
Log recording is enabled for the SSP- related commands on the VIOS command line interface (CLI).
Shared Ethernet Adapter (SEA) accounting enhancements
The SEA accounting functionality monitors the network traffic to and from the client virtual Ethernet adapters it serves. Enhancements have been made in the functionality to reduce the overhead in SEA accounting. This improves the overall SEA performance.
Hardware Requirements
Please check this link for supported hardware.
Known Capabilities and Limitations
The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.
Requirements for Shared Storage Pool
System requirements per SSP node:
Minimum CPU: 1 CPU of guaranteed entitlement
Minimum memory: 4GB
Storage requirements per SSP cluster (minimum): 1 fiber-channel attached disk for repository, 10 GB
At least 1 fiber-channel attached disk for data, 10GB
Limitations for Shared Storage Pool
Software Installation
When installing updates for VIOS Update Release 4.1.2.00 participating in a Shared Storage Pool, the Shared Storage Pool Services must be stopped on the node being upgraded.
SSP Configuration
| Feature | Min | Max |
| Number of VIOS Nodes in Cluster | 1 | 16* |
| Number of Physical Disks in Pool | 1 | 1024 |
| Number of Virtual Disks (LUs) Mappings in Pool | 1 | 8192 |
| Number of Client LPARs per VIOS node | 1 | 250* |
| Capacity of Physical Disks in Pool | 10GB | 16TB |
| Storage Capacity of Storage Pool | 10GB | 512TB |
| Capacity of a Virtual Disk (LU) in Pool | 1GB | 4TB |
| Number of Repository Disks | 1 | 1 |
| Capacity of Repository Disk | 10GB | 1016GB |
| Number of Client LPARs per Cluster | 1 | 2000 |
*Support for additional VIOS Nodes and LPAR Mappings:
Prerequisites for expanded support:
Over 16 VIOS Nodes requires that the SYSTEM (metadata) tier contains only SSD storage.
Over 250 Client LPARs per VIOS requires each VIOS have at least 4 CPUs and 8 GB memory.
Here are the new maximum values for each of these configuration options, if the associated hardware specification has been met:
| Feature | Default Max | High Spec Max |
| Number of VIOS Nodes in Cluster | 16 | 24 |
| Number of Client LPARs per VIOS node | 250 | 400 |
Other notes:
Maximum number of physical volumes that can be added to or replaced from a pool at one time: 64
The Shared Storage Pool cluster name must be less than 63 characters long.
The Shared Storage Pool pool name must be less than 127 characters long.
The maximum supported LU size is 4TB, however for high I/O workloads recommendation is to use multiple smaller LUs as it will improve performance. For example, using 16 separate 16GB LUs would yield better performance than a single 256GB LU for applications that perform reads and writes to a variety of storage locations concurrently.
The size of the /var drive should be greater than or equal to 3GB to ensure proper logging.
Network Configuration
Uninterrupted network connectivity is required for operation. i.e., the network interface used for Shared Storage Pool configuration must be on a highly reliable network which is not congested.
A Shared Storage Pool configuration can use IPV4 or IPV6, but not a combination of both.
A Shared Storage Pool configuration should configure the TCP/IP resolver routine for name resolution to resolve host names locally first, and then use the DNS. For step by step instructions, refer to the TCP/IP name resolution documentation in the IBM Knowledge Center.
The forward and reverse lookup should resolve to the IP address/hostname that is used for Shared Storage Pool configuration.
It is recommended that the VIOSs that are part of the Shared Storage Pool configuration keep their clocks synchronized.
Storage Configuration
Virtual SCSI devices provisioned from the Shared Storage Pool may drive higher CPU utilization than the classic Virtual SCSI devices.
Using SCSI reservations (SCSI Reserve/Release and SCSI-3 Reserve) for fencing physical disks in the Shared Storage pool is not supported.
SANCOM will not be supported in a Shared Storage Pool environment.
Shared Storage Pool capabilities and limitations
On the client LPAR Virtual SCSI disk is the only peripheral device type supported by SSP at this time.
When creating Virtual SCSI Adapters for VIOS LPARs, the option "Any client partition can connect" is not supported.
VIOSs configured for SSP require that Shared Ethernet Adapter(s) (SEA) be setup for Threaded mode (the default mode). SEA in Interrupt Mode is not supported within SSP.
Client LPARs are not supported if they use JFS as their filesystem. If JFS is used, there is a risk of data corruption in the event of a network outage. JFS2 and other file systems are unaffected by this issue.
Installation Information
Pre-installation Information and Instructions
Please ensure that your rootvg contains at least 30 GB and that there is at least 4GB free space before you attempt to update to Update Release 4.1.2.00. Run the lsvg rootvg command, and then ensure there is enough free space.
Example:
$ lsvg rootvg | |||
VOLUME GROUP: | rootvg | VG IDENTIFIER: | 00f6004600004c000000014306a3db3d |
VG STATE: | active | PP SIZE: | 64 megabyte(s) |
VG PERMISSION: | read/write | TOTAL PPs: | 511 (32704 megabytes) |
MAX LVs: | 256 | FREE PPs: | 64 (4096 megabytes) |
LVs: | 14 | USED PPs: | 447 (28608 megabytes) |
OPEN LVs: | 12 | QUORUM: | 2 (Enabled) |
TOTAL PVs: | 1 | VG DESCRIPTORS: | 2 |
STALE PVs: | 0 | STALE PPs: | 0 |
ACTIVE PVs: | 1 | AUTO ON: | yes |
MAX PPs per VG: | 32512 | ||
MAX PPs per PV: | 1016 | MAX PVs: | 32 |
LTG size (Dynamic): | 256 kilobyte(s) | AUTO SYNC: | no |
HOT SPARE: | no | BB POLICY: | relocatable |
PV RESTRICTION: | none | INFINITE RETRY: | no |
VIOS upgrades with Third Party Software
When the user upgrades from 3.1.x.y to 4.1.0.00 level and above, third-party software is not packaged with the IBM supplied mksysb image. User needs to install the respective third-party software after the upgrade is complete and run viosupgrade -o rerun to restore the respective devices.
Updating from VIOS version 4.1.0.00
VIOS Update Release 4.1.2.00 may be applied directly to any VIOS at level 4.1.0.00.
Before installing the VIOS Update Release 4.1.2.00
Warning: The update may fail if there is a loaded media repository.
Instructions: Checking for a loaded media repository
To check for a loaded media repository, and then unload it, follow these steps.
To check for loaded images, run the following command:
$ lsvopt
The Media column lists any loaded media.To unload media images, run the following commands on all Virtual Target Devices that have loaded images.
$ unloadopt -vtd <file-backed_virtual_optical_device >
To verify that all media are unloaded, run the following command again.
$ lsvopt
The command output should show No Media for all VTDs.
Instructions: Migrate Shared Storage Pool Configuration
The Virtual I/O Server (VIOS) Version 3.1.x.y or later, supports rolling updates to release 4.1.2.00 for SSP clusters.
The rolling updates enhancement allows the user to apply Update Release 4.1.2.00 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.
To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:
All VIOS logical partitions must have VIOS Update Release version 3.1.x.y or later installed.
All VIOS logical partitions must be running. If any VIOS logical partition in the cluster is not running, the cluster cannot be upgraded to use the new SSP capabilities.
Instructions: Verify the cluster is running at the same level as your node.
Run the following command:
$ cluster -status -verboseCheck the Node Upgrade Status field, and you should see one of the following terms:
UP_LEVEL: This means that the software level of the logical partition is higher than the software level the cluster is running at.
ON_LEVEL: This means the software level of the logical partition and the cluster are the same.
Installing the Update Release
There is a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.
Instructions: Verifying VIOS update files.
To verify the VIOS update files, follow these steps:
$ oem_setup_env
Create a link to openssl if required
# ln -s /usr/bin/openssl /usr/ios/utils/opensslVerify the link to openssl was created
# ls -alL /usr/bin/openssl /usr/ios/utils/opensslVerify that both files display similar owner and size
# exit
Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.
If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.
Note: While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.
Warning: If VIOS rules have been deployed.
During update, there have been occasional issues with VIOS Rules files getting overwritten and/or system settings getting reset to their default values.
To ensure that this doesn’t affect you, we recommend making a backup of the current rules file. This file is located here:
/home/padmin/rules/vios_current_rules.xml
First, to capture your current system settings, run this command:
$ rules -o capture
Then, either copy the file to a backup location, or save off a list of your current rules:
Note: The "padmin" user is restricted to redirect command output to a file, you must be in the root shell. Use "oem_setup_env" to become a root user.
$ oem_setup_env
# rules -o list > rules_list.txt
After this is complete, proceed to update as normal. When your update is complete, check your current rules and ensure that they still match what is desired. If not, either overwrite the original rules file with your backup, or proceed to use the ‘rules -o modify’ and/or ‘rules -o add’ commands to change the rules to match what is in your backup file.
Finally, if you’ve failed to back up your rules, and are not sure what the rules should be, you can deploy the recommended VIOS rules by using the following command:
$ rules -o deploy -d
Then, if you wish to copy these new VIOS recommended rules to your current rules file, just run:
$ rules -o capture
Note: This will overwrite any customized rules in the current rules file.
Applying Updates
Warning:
If the target node to be updated is part of a redundant VIOS pair, the VIOS partner node must be fully operational before beginning to update the target node.
Note 1:
For VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.
Note 2:
Updateios command is suggested to run using “-install” option. This option installs new base-level filesets that are shipped along with the existing fileset updates. For example: enabling resize command in VIOS 4.1.2.00 onwards.
Running updateios command with “-install” flag may lead to few fileset update error messages that can be ignored. See below the list of filesets for which the error message can be ignored:
X11.apps.msmit 7.3.3.0 # AIXwindows msmit Application
bos.msg.ca_ES.mls.rte 7.3.3.0 # Trusted AIX Messages - Catalan
bos.msg.ca_ES.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.de_DE.mls.rte 7.3.3.0 # Trusted AIX Messages - German
bos.msg.de_DE.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.en_US.mls.rte 7.3.3.0 # Trusted AIX Messages - U.S. ...
bos.msg.es_ES.mls.rte 7.3.3.0 # Trusted AIX Messages - Spanish
bos.msg.es_ES.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.fr_FR.mls.rte 7.3.3.0 # Trusted AIX Messages - French
bos.msg.fr_FR.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.it_IT.mls.rte 7.3.3.0 # Trusted AIX Messages - Italian
bos.msg.it_IT.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.msg.pt_BR.mls.rte 7.3.3.0 # Trusted AIX Messages - Brazi...
bos.msg.pt_BR.svprint 7.3.3.0 # System V Print Subsystem Msg...
bos.net.tcp.rcmd 7.3.3.0 # TCP/IP Remote Command Client...
bos.net.tcp.rcmd_server 7.3.3.0 # TCP/IP Remote Command Server...
Also, In case you choose to run updateios without “-install” flag, you will not see any of the error messages above but you will lose installation of resize command and “RSCT Software Resource Manager” along with a bunch of language message filesets for locales “it_IT, fr_FR, ca_ES, pt_BR, de_DE, es_ES”. Below is the list of filesets that you will miss:
bos.msg.it_IT.txt.tfs - Text Formatting Services Msgs - Italian
bos.msg.it_IT.net.ipsec - IP Security Messages - Italian
bos.msg.it_IT.alt_disk_inst - Alternate Disk Install Msgs -Italian
bos.msg.it_IT.diag.rte - Hardware Diagnostics Messages - Italian
(Same filesets as above for fr_FR, ca_ES, pt_BR, de_DE, es_ES)
X11.apps.xterm - AIXwindows xterm Application
X11.apps.xdm - AIXwindows xdm Application
X11.apps.custom - AIXwindows Runtime Common Directories
X11.apps.config - AIXwindows Configuration Applications
X11.apps.clients - AIXwindows Client Applications
rsct.msg.EN_US.basic.rte - RSCT Basic Msgs - U.S. English (UTF)
rsct.opt.softwarerm - RSCT Software Resource Manager
rsct.msg.en_US.opt.software - RSCT Software RM Msgs - U.S. English
rsct.msg.EN_US.opt.software - RSCT Software RM Msgs - U.S. English (UTF)
Warning:
Update to VIOS 4.1.2.00 will update ios.database.rte fileset which might throw below errors, and they can be ignored:
3001-408 The user "vpgadmin" has an invalid lastupdate attribute.
Instructions: Applying updates to a VIOS.
- Log in to the VIOS as the user padmin.
- If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
- If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.
$ clstartstop -stop -n <cluster_name > -m <hostname > To apply updates from a directory on your local hard disk, follow the steps:
- Create a directory on the Virtual I/O Server.
$ mkdir <directory_name > Using ftp, transfer the update file(s) to the directory you created.
To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:- Mount the remote directory onto the Virtual I/O Server:
$ mount remote_machine_name:directory /mnt
- Mount the remote directory onto the Virtual I/O Server:
The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:
1. Place the CD-ROM into the drive assigned to VIOS.
- Create a directory on the Virtual I/O Server.
- Commit previous updates by running the updateios command:
$ updateios -commit - Verify the updates files that were copied. This step can only be performed if the link to openssl was created.
$ cp <directory_path >/ck_sum.bff /home/padmin
$ chmod 755 </home/padmin>/ck_sum.bff
$ ck_sum.bff <directory_path >
If there are missing updates or incomplete downloads, an error message is displayed.
To see how to create a link to openssl, click here. - Apply the update by running the updateios command
$ updateios -accept -install -dev <directory_name > - To load all changes, reboot the VIOS as user padmin .
- If cluster services were stopped in step 3, restart cluster services.
- Verify that the update was successful by checking the results of the updateios command and by running the ioslevel command, which should indicate that the ioslevel is now 4.1.2.00.
$ shutdown -restart
Note: If shutdown –restart command failed, run swrole –PAdmin for padmin to set authorization and establish access to the shutdown command properly.
$ clstartstop -start -n <cluster_name > -m <hostname >
$ ioslevel
Please run below command to remove unwanted software
$ updateios -remove_outdated_filesets
Post-installation Information and Instructions
Instructions: Checking for an incomplete installation caused by a loaded media repository.
After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.
Check the Media Repository by running this command:
$ lsrep
If the command reports: "Unable to retrieve repository data due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.
Running the lsvopt command should show the media images.
Instructions: Recovering from an incomplete installation caused by a loaded media repository.
To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:
Unload any media images
$ unloadopt -vtd <file-backed_virtual_optical_device>
Reinstall the ios.cli.rte fileset by running the following commands.
To escape the restricted shell:
$ oem_setup_env
To install the failed fileset:
# installp –Or –agX ios.cli.rte –d <device/directory >
To return to the restricted shell:
# exitRestart the VIOS.
$ shutdown –restart
Verify that the Media Repository is operational by running this command:
$ lsrep
Content modified in this release
Software Updated
The filesets that contain the PostgreSQL13 and PostgreSQL15 versions are available in VIOS.
The PostgreSQL15 version is updated to the PostgreSQL15.12 version
The PostgreSQL13 version is updated to the PostgreSQL13.20 version
You must add the -install option while you run the updateios command to install the following PostgreSQL filesets:
ios.viodb13.rte
ios.viodb15.rte
If you don’t have SSP or SSP doesn’t have 4.1.0.00 prior versions nodes, then you may remove ios.viodb13.rte fileset.
Once the ios.viodb13 is removed, the node can never be added back to SSP with prior version nodes.
The Bind.rte fileset is added to the VIOS expansion pack
Content removed from 4.1.0.x release and above
ITM Agents software
ITM (IBM Tivoli Monitoring) filesets are not part of VIOS 4.1.0.00 & above versions. Users need to download and install the ITM software from an external location. The ITM VIOS Premium Agent and ITM CEC Base Agent can be downloaded and installed separately as part of an updated IBM Tivoli Monitoring System P Agents 6.22 Fix Pack 4 or later bundle. Here is a link to the readme file containing information about how to obtain the image and instructions for installing. When these agents are installed in the default directory of /opt/IBM/ITM, they can continue to utilize the cfgsvc, startsvc, and stopsvc commands to configure, start and stop the agent.
AMS
Active Memory Sharing (AMS) feature is removed.
Software Removed
Following filesets that are deemed not necessary are removed.
bos.net.tcp.rcmd, bos.net.tcp.rcmd_server (A copy is saved under: /usr/sys/inst.images/installp/ppc)
cas.agent tivoli.tivguid
rsct.opt.fence.blade rsct.opt.fence.hmc
sysmgt.cim.providers.metrics sysmgt.cim.providers.osbase
sysmgt.cim.providers.scc sysmgt.cim.providers.smash
sysmgt.cim.smisproviders.hba_hdr sysmgt.cim.smisproviders.hhr
sysmgt.cim.smisproviders.vblksrv sysmgt.cimserver.pegasus.rte
Java7.jre Java7.sdk Java7_64.jre Java7_64.sdk
itm.cec.agent itm.premium.rte itm.vios_premium.agent
bos.net.nfs.server devices.vdevice.IBM.vfc-client.rte
X11.adt.ext X11.adt.motif X11.apps.clients X11.apps.config X11.apps.custom X11.apps.msmit X11.apps.xdm
X11.apps.xterm X11.base.xpconfig X11.compat.adt.Motif12 X11.compat.lib.Motif10 X11.compat.lib.Motif114
X11.compat.lib.X11R3 X11.compat.lib.X11R4 X11.Dt.bitmaps X11.Dt.helpinfo X11.Dt.helpmin X11.Dt.helprun
X11.Dt.lib X11.Dt.rte X11.Dt.ToolTalk X11.fnt.coreX X11.fnt.deform_JP X11.fnt.fontServer X11.fnt.Gr_Cyr_T1
X11.fnt.ibm1046 X11.fnt.ibm1046_T1 X11.fnt.iso1 X11.fnt.iso2 X11.fnt.iso3 X11.fnt.iso4 X11.fnt.iso5
X11.fnt.iso7 X11.fnt.iso8 X11.fnt.iso8_T1 X11.fnt.iso9 X11.fnt.iso_T1 X11.fnt.ksc5601.ttf X11.fnt.ucs.cjk
X11.fnt.ucs.com X11.fnt.ucs.ttf_CN X11.fnt.ucs.ttf_extb X11.fnt.util X11.loc.en_US.base.lib
X11.loc.en_US.base.rte X11.loc.en_US.Dt.rte X11.vsm.lib
Fixes included in this release
| APAR | Description |
| IJ52114 | CAA: CAA DISABLE POLLING FOR DOWNED REPO DISK |
| IJ52452 | VIOSBR WRONGLY BACKUP HOSTNAME TO IP CONFIGURED IF NOT IN HOSTS |
| IJ52453 | DUMPCHECK PRINTS UNKNOWN LOCALE |
| IJ52454 | dkeyexch cmd hangs in NIM Master |
| IJ52455 | Dumping SIER, SIER2 and SIER3 registers in P10 |
| IJ52461 | A potential security issue exists |
| IJ52462 | A potential security issue exists |
| IJ52463 | A potential security issue exists |
| IJ52464 | A potential security issue exists |
| IJ52467 | System crash or hang when ipsec and dog threads are enabled |
| IJ52468 | A potential security issue exists |
| IJ52469 | A potential security issue exists |
| IJ52471 | A potential security issue exists |
| IJ52472 | Potential security issue kernext_advisory.asc |
| IJ52473 | Correct SSL code logic and add error handling |
| IJ52474 | Avoiding errpt when cache_mgt cache start is ran. |
| IJ52475 | pmsvcs consumes more pinned memory |
| IJ52478 | MANY HDISK CONFIG 4.1 UPGRADE HAS VIOSBR RESTORE MEM ALLOC FAIL |
| IJ52479 | CRASH DURING REBOOT |
| IJ52481 | WITH SYNCVG THROTTLING A CRASH IN VALIDATE_REQ CAN OCCUR |
| IJ52482 | LPPCHK -F GIVES INCORRECT OUTPUT FOR LARGE SIZED FILES |
| IJ52484 | A potential security issue exists |
| IJ52486 | gencopy errors seen in "nim" update cmd |
| IJ52487 | TPM utilities linking with older version of openssl |
| IJ52488 | VIOS SERVER WITH HIGH NUMBER OF VNIC/ROCE ADAPTERS WON'T BOOT |
| IJ52492 | system crashed in aso_bufmger_stop_cpu_trace |
| IJ52496 | VIOS DR LIBRARY SUPPORT FOR EMC 8500 |
| IJ52497 | Diag menu's FFC001 and FFC002 are not displayed properly |
| IJ52500 | Probable I/O hang during FC link failure error recovery |
| IJ52503 | VIO_HS_ADD_VIOS returning VIO_HS_STOP_VM response |
| IJ52505 | SVC firmware update may cause LPAR hang and IO failure. |
| IJ52618 | WHEN LANG SET TO FR_FR MKCD FAILS WITH 0403-057 SYNTAX ERROR |
| IJ52620 | observed splat coredump |
| IJ52623 | A potential security issue exists |
| IJ52624 | A potential security issue exists |
| IJ52625 | Potential security issue kernext_advisory.asc |
| IJ52626 | Potential security issue kernext_advisory.asc |
| IJ52627 | Password change prompt appears post viosupgrade |
| IJ52629 | Viosupgrade unable to backup rootvg user-defined JFS filesystem |
| IJ52632 | ISST:AUS:rinsev1: Random value "159" in viosupgrade outpu |
| IJ52634 | PERF:LI-19S:Double free with ipsec aes gcm code |
| IJ52640 | ioslevel change for 73H to 4.1.2.00 |
| IJ52641 | RTPG responses larger than 1024 bytes could cause an assert |
| IJ52644 | ragent fails to load the usb mount point for the |
| IJ52648 | VIOS may crash when MODS is enabled. |
| IJ52654 | LOCAL MKGROUP FAILING IF LDAP GROUP EXISTS WITH SAME GID NUMBER |
| IJ52655 | EMGR FAILS WITH AWK ERROR IF TRADEMARK SIGN IN A FILESET'S DESC |
| IJ52656 | UNIXv7: id: exitstatus [^0]" wasn't found in standard out |
| IJ52659 | Error in usage statement for grep.msg and ugrep.msg |
| IJ52663 | Initial 64-Byte size check for LI-157 |
| IJ52666 | PERF:LI 1MT : SYSTEM CRASH DURING RUN IN 73F 2435A |
| IJ52668 | Performance impact with nonblocking UDP socket (EWOULDBLOCK) |
| IJ52673 | nvmehealth shows error: invalid option --o |
| IJ52692 | RENAMED LV IN IMAGE.DATA IS NOT UPDATED AFTER ALT_DISK_COPY. |
| IJ52714 | AUTHENTICATION WITH EFS LEAK WHEN KEYSTORE DOESN'T EXIST |
| IJ52715 | MKSECLDAP HANG |
| IJ52716 | AUDITPR DOES NOT SUPPORT SINGLE LINE OUTPUT FOR MULTI LINE EVENT |
| IJ52721 | A potential security issue exists |
| IJ52726 | LOCKING ISSUE IN VIRTUAL ADAPTER DRIVER CAUSES COMMAND AND PARTI |
| IJ52727 | GETCONF DISKSIZE RETURNS INCORRECT LUN SIZE FOR FC-NVME DISKS |
| IJ52728 | VNICSTAT NOT WORKING FOR PADMIN AFTER UPDATE |
| IJ52730 | System may crash during FC-NVMe protocol driver configuration. |
| IJ52731 | correcting DD_ENTRY_BSTART trace entry |
| IJ52769 | ALTERNATE ROOTVG OPERATIONS FAILS IN TRUSTED ENVIRONMENT |
| IJ52770 | UNIXv7:SIGCHLD is not pending after wait() |
| IJ52771 | AUTHENTICATE() MIGHT RETURN ENOENT INSTEAD OF ENOMEM |
| IJ52778 | Updating timezone data files to latest 2024b database |
| IJ52837 | trustchk coredump with Ptools bucket exec |
| IJ52883 | NIM_RESOURCES.TAR CREATION USES EXCLUDE.ROOTVG FILE |
| IJ52890 | RARE CRASH WHEN STARTING SYSTEM TRACE IN PERFPMR |
| IJ52891 | Link Speed status shows "Unknown" for SRIOV VF port |
| IJ52892 | POSSIBLE DSI IN ISCSISW_NEXT_WAITING_DEV() |
| IJ52894 | aix vscsi client may hang in rare case. |
| IJ52895 | HST 1060.20 SP: Inactive LPM is failing for NPIV lpar with HSC |
| IJ52915 | mallocdebug log fails to log stacks in monothreaded |
| IJ52916 | vmstat output fi/fo seems incorrect when system is in a paging |
| IJ52951 | Incomplete output by "malloc allocation size==X" command in dbx |
| IJ52962 | JAVA 21: PROBLEM EXTRACTING FILES FROM JAR/ZIP WITH NX/GZIP |
| IJ52967 | Logs in ASO to capture reason for unsuccessful SHM promotions |
| IJ52968 | INSTFIX FAILS TO LIST EFIXES WITH ABSTRACTS LONGER THAN 64 |
| IJ52972 | PASSIVE VG FAILS TO VARYON AFTER LKU WITH POWERHA |
| IJ52973 | SGID NOT PRESERVED WHEN IFIX IS INSTALLED IN NIMADM |
| IJ52998 | DEFRAGFS -F ON A LARGE JFS2 FILESYSTEM MAY CAUSE CORRUPTION |
| IJ53043 | find command might not work due to mount permissions |
| IJ53047 | SHUTDOWN REPORTS FAILURES DUE TO /DEV/CONSOLE NOT AVAILABLE |
| IJ53056 | EMGR_SEC_PATCH MAY FAIL TO INSTALL IFIX |
| IJ53081 | VIOS may crash at npiv_init_cmd |
| IJ53138 | SYSTEM CRASH IN SELPOLL() |
| IJ53139 | Debug info to print the process tree in case of checkpoint fail |
| IJ53140 | FORCE UNMOUNT OF A J2 FILESYSTEM MAY TAKE LONGER UNDER NFS ENV |
| IJ53141 | kernel assert, if vsid is invalid in vm_attinfo |
| IJ53142 | EIO ERRORS FOR LOCK REQUESTS DUE TO BAD_SEQID |
| IJ53143 | MISSING -EXCLUDE FLAG IN BACKUPIOS HELP |
| IJ53144 | BACKUPIOS CAN HANG WHEN THE STDERR IS BIGGER THAN 32K |
| IJ53146 | DUPLICATE UDP SOCKETS CAN GET CREATED CAUSING CONNECTION ISSUES |
| IJ53147 | EXTENDLV WITH MIRROR POOLS MAY ALLOCATE PARTITIONS INCORRECTLY |
| IJ53158 | Config Script Failures Due to Broken Pipe Fix |
| IJ53159 | diff command fails with Standard error is empty |
| IJ53160 | sh: Broken pipe msg displayed during migration. |
| IJ53161 | PORT SPEED IS UNKNOWN FOR FC ADAPTER |
| IJ53162 | SECLDAPCLNTD HANG WHEN USING NETCD |
| IJ53225 | REPLACE 'IBM' WITH 'IPS' IN AIX COMMAND OUTPUTS ON IPS HARDWARE |
| IJ53226 | AVOID ACS_SLOCK CONTENTION CAUSING NETWORK DELAYS |
| IJ53227 | LNC2ENTDD NEEDS LSO SECURITY CHECK IN VNIC PATH |
| IJ53228 | ADAPTER RATE REPORTING INCORRECT INFO |
| IJ53230 | RoCE adapter's NIC VF's uses extra 128M though not required |
| IJ53231 | REORGVG TERMINATION MAY HANG THE PASSIVE NODE DURING FAILOVER |
| IJ53233 | rest7 testcase failure |
| IJ53234 | DEFERD:UNIXv7: SigWait: child exited with code 130 |
| IJ53236 | POTENTIAL CRASH IN BERKLEY PACKET FILTER (BPF) DRIVER |
| IJ53240 | host -n should give error mesage for new bind.rte |
| IJ53241 | Getting usage error for mkldap with invalid values |
| IJ53242 | encr not disabled for hd7 |
| IJ53342 | Dynamic tuning of the lldp_mode not reflected in Etherchannel |
| IJ53348 | SYSTEM CRASH IN XM_BAD_FREE CALLED FROM ASO_THCP_START_STOP_TRC |
| IJ53350 | FC SCSI DRIVER IDENTIFIES ITSELF AS TARGET |
| IJ53351 | TE: signature is volatile, hash verification is also skipped |
| IJ53378 | ADD SANITY CHECKS TO NFS READDIR |
| IJ53379 | ADD VNODE-RELATED TRACING |
| IJ53383 | ISST:Observed crash -> Kernel abend_trap for check_free sta |
| IJ53384 | Tampering cert. file doesn't fail emgr_download_ifix execution |
| IJ53435 | DEV: clutil tool needs to refer to the absolute python path. |
| IJ53436 | iso_addr() is not returning proper value. |
| IJ53439 | AIX not using drive reported ANATT values |
| IJ53440 | tsd,lib.dat on LDAP for updates of .a can lead to hash mismatch |
| IJ53464 | THE BOS.LOC.UTF LANGUAGE FILESETS BROKEN DURING TL UPDATE |
| IJ53503 | INCOMPLETE ARRAY TYPE FREE_SOCK_HASH_TABLE |
| IJ53504 | nimadm to 7300-03 may lose user fs from /etc/filesystems |
| IJ53505 | failed to download CRL |
| IJ53507 | Wrong/junk machine SN number going in json request packet |
| IJ53508 | handling return code value of emgr* script |
| IJ53509 | epkg not generating secfiles |
| IJ53525 | DEV: viosbr -dr is unable to restore the lu mappings (SSP). |
| IJ53538 | rmvirprt core dump |
| IJ53544 | APP HANG DUE TO RACE CONDITION BETWEEN SOCKET READ AND CLOSE |
| IJ53576 | Signature verification failed for /usr/sbin/snmpd |
| IJ53577 | LPPCHK -F REPORTS FILE SIZE AS 0 INCORRECTLY IN AIX 7.3 TL3 |
| IJ53578 | du command in baselib_sh.sh throws error with XPG_SUS_ENV=ON |
| IJ53579 | /etc/qconfig entries corrupted |
| IJ53582 | Performance loss on AIX 7.3 TL3 with offload_iodone enabled |
| IJ53589 | 2025a timezone database update |
| IJ53619 | CRASH DUE TO INVALID PAGE FAULT IN NFS4_ANY_LOCK |
| IJ53622 | RMDEV COMMAND MAY HANG WHEN REMOVING FC ADAPTER AFTER EEH EVENT |
| IJ53623 | DURING HBA FW DOWNLOAD VIOS LOGS FCA_ERR4 WITH 0X3E |
| IJ53624 | IO MAY FAIL AFTER DYNAMIC TRACKING FAILURE |
| IJ53626 | SEA stats shows garbage values when there is ctrl channel of it. |
| IJ53628 | customer reported hung while deleting a file under JFS2 filesys |
| IJ53631 | POSSIBLE STACK CORRUPTION WHEN MLXCENT_HW_TX_DESC_WRITE() CALL |
| IJ53648 | OSLEVEL COMMAND MIGHT DISPLAY INCORRECTLY IN 7300-TL3 |
| IJ53662 | lku of powervc managed lpar may remove disk from lpar |
| IJ53695 | VIOS/AIX boot may hang during Broadcom FC HBA config |
| IJ53696 | AIX may crash after io_dma set to 2048 per fcs port. |
| IJ53697 | Probable system crash at xm_bad_free |
| IJ53700 | Update kernel copyright notice for 2025 |
| IJ53701 | SNAP SVCOLLECT GENERATES PERMISSION DENIED IN SVCOLLECT.ERR |
| IJ53702 | SSPDB IS MISSING(SNAP SVCOLLECT IN PADMIN):PG_VERSION NOT EXIST |
| IJ53727 | GENFILT NOT RECOGNIZING DUPLICATED RULES FOR PORT 32768 AND UP |
| IJ53735 | SNAP SVCOLLECT DO NOT COLLECT VIOSVC.OUT & VIOSVC.ERR |
| IJ53739 | Poor network performance because of shared global variable |
| IJ53755 | Lock contention issue during relogin to an iSCSI target device |
| IJ53756 | FUSER WITH -D OPTION MAY NOT OUTPUT ALL TEMPORARY FILES |
| IJ53768 | PARTITIONS (P9/P10 MODE) CRASH AFTER SMTCTL -M LIMIT |
| IJ53769 | LPAR HUNG REQUESTING A SNAP OR DUMP ANALYSE |
| IJ53772 | unexpected ASYNCHRONOUS EVENTS default behavior |
| IJ53795 | DSI IN DISPATCH() DUE TO INCONSISTENCIES IN THE THREAD STRUCTURE |
| IJ53798 | create UUID for iscsi disks with product id iSCSI_VDASD |
| IJ53818 | NMON VOLUME-GROUP MISLEADING WHEN AIX HAS VARYOFF VG |
| IJ53819 | ERRORS LOGGED APPLYING VIOS 4.1.1 IOS.ARTEX_PROFILE.RTE |
| IJ53820 | A potential security issue exists |
| IJ53821 | nimsh subsystem args should not preserve '-c' during reinit |
| IJ53822 | nimclient -l lists resources from wrong customer object |
| IJ53827 | KERNEL EXTENSIONS CODE AND DATA NOT ACCESSIBLE IN DUMPS |
| IJ53829 | A potential security issue exists |
| IJ53830 | A potential security issue exists |
| IJ53955 | CRASH IN BUILD_MAP_LIST AT BOOT SRC 888-102-300-0C5 |
| IJ53957 | RR_START failed with EBUSY during |
| IJ53958 | SYSTEM CRASH IN RTFREE() WITH CACHED_ROUTE NO OPTION ENABLED |
| IJ53965 | COMMANDS LIKE LSNPORTS, LSMAP, FCSTAT, SNAP HANG ON VIOS |
| IJ53969 | EMGR_CHECK_IFIXES FAILS WITH CRLFILE_NAME CANNOT CREATE |
| IJ53971 | FREELIST_KPROC() CONSUMING HIGH AMOUNT OF CPU |
| IJ53972 | NIM ADAPTER_DEF OPERATION FAILS WITH NFSV4 |
| IJ53973 | tcp_init_window no option displays incorrect unit type |
| IJ53975 | NIM TAKEOVER FAILS FOR CLIENT WITH SIT INTERFACE CONFIGURED |
| IJ53983 | A potential security issue exists |
| IJ53984 | A potential security issue exists |
| IJ54009 | FOC73F_SP1:FVTR-DEV:IO failed on RDX after EEH recovery |
| IJ54015 | emgr_check_ifixes doesnot recognize VIOS OS correctly |
| IJ54058 | OpenxlC fails while compiling code with -D_LINUX_SOURCE_COMPAT |
| IJ54069 | ALT_DISK_COPY "NO SUCH DEVICE OR ADDRESS" WARNING MESSAGE |
| IJ54071 | CLIENT IO MAY HANG OR FAIL |
| IJ54142 | Application variable resetting to NULL post LLU in p_option() |
| IJ54145 | NON ROOT USER WITH RBAC ROOT PRIVILEGES CANNOT RUN SENDMAIL |
| IJ54147 | NFSV4 GROUP IS SHOWING AS NOBODY IF IT HAS MANY USERS |
| IJ54149 | access to double type variable broken with 64-bit assembler |
| IJ54155 | dumpcheck command fails in any locals except C |
| IJ54162 | SYSTEM HANG DUE TO DEADLOCK BETWEEN AHANODE LOCK AND PV_LOCK |
| IJ54163 | LISTING NIM FILESETS ON MASTER FROM NIM CLIENT BE SLOW OR HANG |
| IJ54233 | SYSTEM CRASH IN FASTLO_SETUP |
| IJ54234 | POTENTIAL CRASH IN ALIGNMENT FAULT HANDLER |
| IJ54240 | Reduce the traces in tcp path related to DSS |
| IJ54243 | NFS4 MOUNT FAILS IN NIMADM SETUP FROM AIX 73 TL 1 LEVEL |
| IJ54244 | LKU: INCREASED BLACKOUT DUE TO NFS MOUNT POINT RESTORE |
| IJ54290 | POST VIOSUPGRADE 4.1, 3 FILES HAVE WRONG GROUP/MODE (TRUSTCHK) |
| IJ54291 | ipsec_logd not automatically stopped during LKU |
| IJ54301 | Ports become unavailble for EC3M because of EEH |
| IJ54302 | Potentially higher IO service time with iodone offload |
| IJ54454 | Signal context not stored properly during LLU |
| IJ54463 | lgamma setting ERANGE for NaN |
| IJ54464 | SYNCVG -Q MAY CORE DUMP IF MULTIPLE SYNCVG IS RUN CONCURRENTLY |
| IJ54471 | SYSTEM CRASH RAS_KRPC_SRV_REGISTER / KRPC_RTEC_ERROR_HANDLER |
| IJ54472 | NIM MKSYSB MAY FAIL WITH LANG=EN_US.UTF-8 |
| IJ54476 | Ctrl+X to dconsole read mode terminates HMC console |
| IJ54507 | 'snap' command hangs during lvm data collection if VG is locked |
| IJ54508 | FOC73F_SP1:UNIXv7:Standard output not same as file test.714.eso |
| IJ54511 | _LARGE_FILES macros cause conflicts with C++ open |
| IJ54512 | GZIP QOS CREDIT ADD FAILS DUE TO DRSLOT_CHRP_ACC TIMEOUT |
| IJ54517 | VIOS snap file have insufficient permissions for padmin user |
| IJ54580 | DR CPU REMOVAL FAILURE WITH EBUSY |
| IJ54583 | LDAP FAILED TO SEARCH ERROR WITH CHARACTER |
| IJ54585 | chfs -a logshuffle={INLINE} fails to update LVC |
| IJ54586 | UNEXPECTED "USAGE:" MESSAGE FOR 'LSATTR' WHEN COLLECTING 'SNAP' |
| IJ54588 | EFS ENABLEMENT FOR MKSYSB ON TAPE |
| IJ54648 | LPAR got crashed with stack vioent_hw_send with tracelevel >=4 |
| IJ54649 | NIMADM FAILS MOUNT FILE TYPE RESOURCES WITH NFSV4 |
| IJ54680 | FILENAME NOT DISPLAYED IF FULLPATH=ON AND FILE_OPEN EVENT FAILS |
| IJ54681 | customer reported crash due to high aio pinned memory consumpti |
| IJ54685 | MPSTAT REPORTING FAR DISPATCHES WITH SINGLE SRAD |
| IJ54687 | unknown millicode error on P10 LKU. |
| IJ54689 | LLU got hung in phase1 with DT7 |
| IJ54690 | system crashed with pvthread+00D800 |
| IJ54692 | Crash with diag update of invalid secured firmware image |
| IJ54693 | Probable system crash at iodone(). |
| IJ54695 | System crash @netkmem_dr_cpu_remove during drmgr operations. |
| IJ54696 | system hung @malloc_thread+000500 |
| IJ54697 | bulk_unmap:check TCE_MIRROR_REMOTE flag for finding remote TCE |
| IJ54706 | PERF:LI-2E2:ORA-03114: not connected to ORACLE POST LLU |
| IJ54733 | viosbr restore fails network restore for incorrect ent config |
| IJ54734 | checkin ESA Aix for Call Home Connect Cloud(CHCC) files |
| IJ54737 | ASO core dump while trying to query for WLM data |
| IJ54738 | SNAP files are not getting removed after sending transaction |
| IJ54740 | ASO may core dump when LRU is active. |
| IJ54744 | bos.diag.rte.config_u failure during update from 73D to 73F |
| IJ54748 | suma -x fails due to newline char in oslevel output' |
| IJ54749 | LKU may fail after performing upgradation from 73D/73F to 73H |
| IJ54751 | LI-2E2:Debug tools needs to updated with new vapi glue code add |
| IJ54834 | TEMPORARY AUTH / PASSWDEXPIREDX FAILURES FOR LDAP |
| IJ54835 | SECLDAPCLNTD MEMORY LEAK USING STARTTLS |
| IJ54840 | Tunnels are failing when IKE_PRF is set to NONE |
| IJ54841 | ICONV CAN HANG PROCESSING INPUT DATA |
| IJ54847 | dgetmacs multi_node cmd fails via openfirmware |
| IJ54852 | Handle port login failures for ESTALE |
| IJ54855 | vios crash during lpm at valvfc_off_level |
| IJ54863 | LKU for AIX TL upgrade failed. |
| IJ54897 | llvupdate command shows success even for failure cases |
| IJ54899 | KSH MAYBE SLOW ON EXIT DUE TO CONTENTION ON /TMP |
| IJ54900 | HANG DUE TO MAILBOX TIMEOUT IF ADAPTER MICROCODE DOWNLOAD FAILS |
| IJ54901 | error when one Crypt device is Defined and is Available |
| IJ54903 | System may crash with bad IAR at arptime() |
| IJ54904 | SEA_TRACE LOCKING CONTENTION |
| IJ54905 | ALT_DISK_COPY NOT PRESERVING EFS MOUNT POINTS. |
| IJ54906 | RDS causes system crash during rds_ib_conn_shutdown() |
| IJ54932 | emgr_check_ifixes fails |
| IJ54951 | VIOSECURE VIEW INCORRECTLY LISTS NTP FOR ALL BLANK SERVICE |
| IJ55018 | RSH OR OTHERS MAY FAIL WITH FQDN IN RHOSTS FILE |
| IJ55029 | A potential security issue exists |
| IJ55035 | PARTITION CRASH WITH DBX ON PROCESS ( HUGE NTHREADS) |
| IJ55037 | CHROOT() MIGHT LEAK KERNEL HEAP FOR CREDALLOC |
| IJ55043 | sea component trace level is 7 by default. |
| IJ55051 | RENDEV FAILS WITH INCORRECT ERROR MESSAGE |
| IJ55053 | Cgo programs failing with Segmentation fault |
| IJ55057 | SOME VIOS CMDS HANG AFTER LPM VALIDATION |
| IJ55058 | CMDB MEM LEAK LEADS TO CORE DUMP |
| IJ55065 | viosupgrade from 72X to 73F might fail due to viosbr restore |
| IJ55070 | move pvc based clone just before alt_disk_copy |
| IJ55125 | FTPD CORE DUMP WHEN TRYING TO LOCK GLOBAL PTHREAD MUTEX |
| IJ55130 | A potential security issue exists |
| IJ55133 | SRN FFC-601 is not observed after running the vanguard |
| IJ55136 | System crash at llvupdate thread |
| IJ55138 | System crash when LLU fail |
| IJ55158 | NO -L DISPLAY WRONG VALUE |
| IJ55159 | LSATTR CANNOT DISPLAY FB_DELAY VALUE RANGE |
| IJ55161 | LLU fails to update libpthreads.a library for IBM.softwareRMd |
| IJ55194 | SYSTEM MAY CRASH IF JFS2 FILE EXTENDED ATTRIBUTE IS CORRUPTED |
| IJ55195 | customer reported slow reads from jfs2 snapshots on 7.3 TL2 |
| IJ55196 | Crashes in iKill during rename or rmdir operations |
| IJ55198 | curt Trace/BPT trap |
| IJ55199 | IKEDB -P :LSP FUNCTION DETECTED A BAD PARAMETER |
| IJ55200 | simplelparstat display incorrect output. |
| IJ55203 | udapl fileset should have prerequisite on OFED fileset |
| IJ55221 | LKU fails while creating the swap device. |
| IJ55224 | TAR AND PAX MALLOC ERRORS WHEN RESTORING SOME GNU TAR FILES |
| IJ55229 | VIOS_VFC_HOST(0000 016F) TIMED OUT WAITING CMDS_IN_USE TO BE 0 |
| IJ55230 | cfgmgr hanged with ucfg/cfg loop |
| IJ55232 | npiv path failure after upgrade |
| IJ55233 | Passthru Error on VIOS |
| IJ55236 | Unmapping the vfchost returns device is busy error |
| IJ55237 | New return code for vfchost unmap fail with device is busy error |
| IJ55247 | DSI IN NPIV_TAKE_THREAD_ACTION WITH CTCTRL IN VIOS 4.1.1.0 |
| IJ55265 | VMR deadlock when VIOS missing HSDB entry |
| IJ55274 | HEAVY VIO CHANGE MANAGEMENT ACTIVITY CAN HANG VIO_CHGMGT DAEMON |
| IJ55275 | Creation of Etherchannel allowed when adapter is unavailable |
| IJ55276 | llu update fails in few scenarios |
| IJ55280 | I/O FAILURE DURING CHVG -G CAN LEAVE INCORRECT STALE BITS |
| IJ55293 | NIMADM FAILS TO INSTALL RPM PACKAGES FROM INSTALL_BUNDLE |
| IJ55294 | ISST:LI-08H:restvg comes out without asking another confirmatio |
| IJ55298 | 1W6 Backout for NIM Vulnerability alignment |
| IJ55324 | SPOT CREATION WITH THE ATTRIBUTE SHOW_PROGRESS=NO IS FAILING |
| IJ55325 | SPOT CREATION WITH AUTO_EXPAND=NO STILL EXPANDING FILESYSTEM. |
| IJ55326 | Pseudo tunnels(gre/gne/vxl) do not persist across reboot |
| IJ55329 | RDSv2 load failure still displays RDSv2 help for "rdsctrl -h" |
| IJ55333 | CTIU timeout after SAN fabric event may result in command hang |
| IJ55334 | OPEN AND CLOSE OF PASSIVE MWC LVS IN CONCURRENT VG MAY HANG |
| IJ55337 | UNIXv7: ASYNCHRONOUS EVENTS default behavior doesn't work |
| IJ55338 | A potential security issue exists |
| IJ55339 | UNIXv7: Command 'compress -f' had unexpected wait status |
| IJ55341 | GROUP MEMBERSHIP NOT FOUND / AT JOBS FAIL |
| IJ55342 | nfsmnthelp core dumps with tcpip regression |
| IJ55346 | SYSTEM HANG IN CM_REJ_HANDLER() |
| IJ55362 | SYSTEM CRASHES IN IP6_OUTPUT() |
| IJ55370 | CRASH USING TRANSACTIONAL MEMORY WITH AIX 7300-01 ON POWER8 |
| IJ55374 | PROBABLE FCSTAT HANG ON UNUSED FC ADAPTER PORT |
| IJ55377 | vfcmap or lsmap command may hang |
| IJ55382 | FOC73H:mksysb restore fail if we don't pass -a during mkvg op |
| IJ55388 | LSLPP CORE DUMPS WHEN DESCRIPTION STRING IN VENDOR ODM TOO LONG |
| IJ55389 | MKLV CAN CREATE AN LV WITH INVALID STRIPEWIDTH / MIRPOOLS |
| IJ55392 | UNIXv7: kill -l exit_status returns signal name fail |
| IJ55393 | WRONG ERROR MESSAGE FROM MV COMMAND |
| IJ55394 | lsmcode may not display adapters firmware level |
| IJ55395 | Live update fails in blackout while creating the swap devices. |
| IJ55435 | Support hkeyset_* functions in sys/skeys.h with OpenXL |
| IJ55437 | LKU WITH IPSEC FAILS WITH CHECKPOINT FILE PROBABLY CORRUPTED |
| IJ55439 | viosupgrade tool might fail for custom mksysb image. |
| IJ55441 | viosbr restore fails in some specific cases with etherchannel |
| IJ55442 | ASO dumping core occasionally when WLM is toggled |
| IJ55446 | dumpcheck fails on exceeded variable values |
| IJ55449 | LI-2E2:ISST:LLU is generating DB2 core :denfallcog03 |
| IJ55450 | Output of 'lsfs -q' needs to be improved if vg is varied off |
| IJ55451 | UNIXv7: Unexpected wait status reported by SigWait |
| IJ55452 | UNIXv7: Standard error is empty with sort command error |
| IJ55453 | UNIXv7: Command 'awk 1' had unexpected wait status |
| IJ55454 | UNIXv7: Command 'dd' had unexpected wait status |
| IJ55455 | UNIXv7: kill -s signal_name pid generates incorrect exitstatus |
| IJ55458 | INTR_CNT PARAMETER HAS NO USE IN EN2W AND SHOULD BE REMOVED |
| IJ55460 | MEMORY CAN LEAK FROM VIOS KERNEL EXTENSION DURING HEAVY CHANGE |
| IJ55463 | SCAL_VMR_HA: adms failed in discovery |
| IJ55464 | AIX/VIOS crashed at emfsc_npiv_scsi_cancel |
| IJ55466 | POTENTIAL CRASH IN UDOORBELL_DESTROY (RDMA) WITH DB2 PURESCALE |
| IJ55553 | UNIXv7: SigWait: child exited with code 2 |
| IJ55554 | UNIXv7: unexpected wait status when testing SIGUSR1 inherited |
| IJ55559 | trucstchk verification failed during updateios |
| IJ55564 | DR MEMORY REMOVAL PARTIAL FAILURE ON POWER10 WITH AIX 7300-03 |
| IJ55573 | A potential security issue exists |
| IJ55574 | A potential security issue exists |
| IJ55612 | NIMADM MKSYSB MIGRATION FUSER WARNINGS IN PHASE 10 |
| IJ55613 | ISST:everestauto01:hdcryptmgr not giving proper error for inval |
| IJ55614 | System Crash seen during ESP testing iperf3 |
| IJ55621 | IO SPACE MAPPING CREATED W. RMMAP_INHERIT NOT INHERITED AT FORK |
| IJ55622 | library load issue causing SIGILL / SIGSEGV |
| IJ55653 | nim_cli errors in bos_inst push/pull install |
| IJ55658 | drvars KDB command failure due to data storage interrupt |
| IJ55666 | NIMADM WITH DISK CACHING SHOWS BACKUP 0511-449 ERRORS IN PHASE 3 |
| IJ55668 | HDC_AuthAdd,HDC_AuthDel,HDC_CLI events not log as rbac |
| IJ55669 | ISST::STALE pks keys export needs to be corrected. |
| IJ55670 | DEFERD:FVTR-DEV:coredump in snmpd64v1 |
| IJ55671 | FOC73H:ISST:IPSEC:Coredump during ipsec device removal |
| IJ55672 | trustchk not updating the symlinks after switching |
| IJ55675 | A potential security issue exists |
| IJ55704 | iscsi memory leak |
| IJ55772 | /usr/bin/su dumped core on krb5 |
| IJ55773 | ISST:BLK:System not booting up and hung at 0555 LED code : |
| IJ55775 | UNIXv7: rename() doesn't work across file systems |
| IJ55776 | UNIXv7: tee command generates error with non-zero status |
| IJ55780 | ZTEA:inconsistency in tsd and lib.tsd while adding and removing |
| IJ55781 | MKVGDATA INCORRECTLY SAVES ATTRIBUTES OF VG IN CONCURRENT MODE |
| IJ55782 | NIMADM -U FAILED TO WORK WITH A MIXED LPP_SOURCE |
| IJ55783 | NIM KSH:0403-057 ERROR USING RSH |
| IJ55785 | Event not getting logged when tunnel activated by RBAC |
| IJ55786 | Tunnel_create audit event printing ESP SPI as AH SPI |
| IJ55787 | 'nfsd -getreplicas' does not return proper output |
| IJ55788 | nfswrite() trace display incorrect write count value |
| IJ55789 | LKU failed during unloading of unsafe kernel extensions. |
| IJ55790 | cache_mgt partition unassign fail on defined disk |
| IJ55793 | srcloop daemon dumps core |
| IJ55794 | tcpdump may fail to capture the packets |
| IJ55796 | A potential security issue exists |
| IJ55797 | A potential security issue exists |
| IJ55798 | A potential security issue exists |
| IJ55804 | A potential security issue exists |
| IJ55805 | crash in bpf_aix_mtap with stress test |
| IJ55807 | Compiler warning about long type in place of int for ioctl macro |
| IJ55808 | FCA_ERR6 when switch RDP polling cycle is turned on |
| IJ55809 | SSP DBN election progress gets blocked. |
| IJ55810 | Fix log cleanup script on VIOS. |
| IJ55811 | CAVIUM REACTION ON FLOGO FROM CISCO SWITCHES |
| IJ55812 | RAS:Trace Adjustments with FC drivers. |
| IJ55814 | vm discovery and restart failing with VIOS 73H |
| IJ55819 | VLAN priority wrong for RoCEv1 packets |
| IJ55820 | Auditing wpar from global unable to produce audit log |
| IJ55821 | Fullpath is not retained after audit off/on |
| IJ55822 | 1MT: Change the way we look for new RQ in setrq |
| IJ55823 | LKU failed with different error. |
| IJ55826 | 3rd LLU fails for delta vapi library versions |
| IJ55832 | LLU 2E2 : MALLOCDEBUG=report_allocations display improper stack |
| IJ55833 | LKU in hung state |
| IJ55871 | Platform dump offloaded to AIX may not be proper |
| IJ55873 | Switch crashes while xm tries to switch cpu in a debug kernel |
| IJ55875 | UNIXv7: utility doesn't treat SIGTTOU inherited as default |
| IJ55876 | UNIXv7: exitstatus wasn't found in standard output |
| IJ55880 | A potential security issue exists |
| IJ55886 | A potential security issue exists |
| IJ56079 | skctl -u is giving usage for valid value |
| IJ56080 | Audit getting turned on during LKU. |
| IJ56081 | FOC73H:UNIXv7:Config Script Failures Due to Broken Pipe Fix |
| IJ56082 | system crashed after syncing |
| IJ56083 | UNIXv7: Command /usr/bin/time had unexpected wait status |
| IJ56088 | VIRTUALCFG CORE DUMPS WARN_USERFS |
| IJ56089 | Adding 3rd party backup repo disk to local site in LC failing |
| IJ56091 | virtualcfg in vios may get coredumped |
| IJ56096 | A potential security issue exists |
| IJ56106 | tcpdump is not capturing packet with bpf_perf=1 |
| IJ56108 | nimadm not failing when UAK on lpar expired |
| IJ56166 | Bug in pagerDevice objects allocation |
| IJ56167 | Rare crash in j2_rename() when unlocking with a NULL pointer |
| IJ56169 | Improper value observed in IPSEC_lstun for IKE tunnels |
| IJ56170 | NIM client with obselete hostname fails to remove |
| IJ56174 | BLK:FVLI-04D:VTD disk are defined in vios and VM failed |
| IJ56175 | A potential security issue exists |
| IJ56180 | Raise exception if VIOS is not a HM during ADD_VM. |
| IJ56181 | AIX LPAR may crash at fcnvme_chn_io_kthread_worker |
| IJ56185 | TRUSTCHK DOES NOT RECOGNISE DIR IN /ETC/SECURITY/CERTIFICATES/ |
| IJ56186 | UNIXv7: interrupt char;ends cmdline editting reissues a prompt |
| IJ56187 | UNIXv7: current suspend character suspends ex |
| IJ56188 | A potential security issue exists |
| IJ56191 | A potential security issue exists |
| IJ56192 | PENTEST: Arbitrary File Write - _print_bucket_stats() |
| IJ56203 | NIMADM phase 6 interruption with INST_DEBUG=yes |
| IJ56204 | lldpsync command is removing ports from lldp management. |
| IJ56205 | Fix cppcheck errors in hdcrypt component |
| IJ56207 | ISST:rampv1:dumped at drw_lock_done_ppc |
| IJ56212 | Turn off debug and no-ship defines for production build |
| IJ56214 | sysdumpdev output has extra characters |
| IJ56215 | sysdumpstart with FW assisted dump fails with unclear message |
| IJ56219 | UNIXv7: suspend with job control disabled in invoking shell |
| IJ56220 | cfgmgr may hang when configuring NVMe over TCP disks. |
| IJ56224 | exec call fails and wrong error message is displayed when filename > MAX_CHAR |
| IJ56225 | ASO coredump after LLU+LKU |
| IJ56226 | ISST:LI-2E2:blk:llvupdate program core dump |
| IJ56227 | 1U1:ISST:VIOS got crashed as part of vfcmapping/unmapping |
| IJ56228 | Change default kernel to non-debug |
| IJ56322 | An "891A3632" errpt entry may be reported if drive does not |
| IJ56330 | viosbr -dr cluster restore is failing on 73H nodes. |
| IJ56332 | viosupgrade nim version took more than 3 hou |
| IJ56333 | viosupgrade restore failed from Spring 72Z |
| IJ56334 | ISST:LI-2E2:blk:nfsrgyd core dump during library update |
| IJ56375 | restvg fails with locked PV |
| IJ56377 | FOC73H:ISST: Lpar got crashed @ e_assert_wait_ext+0000B8 |
| IJ56431 | UNIXv7: SIGINT SIGQUIT SIGTERM are ignored by interactive shel |
| IJ56447 | pthread_create might fail after LLU |
| IJ56450 | mlxcentdd entstat should display all Traffic Class under [PPCNT - Priority] |
| IJ56500 | IO may hang in certain target side cable pull scenarios |
| IJ56504 | A potential security issue exists |
| IJ56505 | A potential security issue exists |
| IJ56506 | A potential security issue exists |
| IJ56508 | Warnings and Debug Msgs in nimadm operation |
| IJ56509 | LI1ZM:"nimadm" fails on 72Z NIM_cli from 73H NIM_mstr |
| IJ56510 | update install with nimadm not failing in prop |
| IJ56511 | BLK:FVLI-2E2:System crashed with printer job execution |
| IJ56518 | AIX/VIOS may crash at emfsc_strategy |
| IJ56521 | A system crash may occur during the LLU operation. |
| IJ56522 | LLU followed by LKU fails with delta vapi library |
| IJ56524 | iptrace not working with -B option with bpf_perf enabled |
| IJ56525 | trustchk error message for mkauthkeys |
| IJ56527 | hdcryptmgr coredumped for pvdisable |
| IJ56530 | UNIXv7: Command 'lp -s -d lp0' had unexpected wait status |
| IJ56568 | bosinst_log error observed in 2533A_73H UPD WB |
| IJ56569 | ISST:metisv2: viosupgrade nim version is failing at the u |
| IJ56570 | blackout time est. model update |
| IJ56575 | IO may hang in certain target side cable pull scenarios |
| IJ56578 | UNIXv7: dd fails to set error when SIGINT received |
| IJ56623 | Undo 1188842 changes that are not required |
| IJ56629 | mksecldap does not reflect -R flag |
| IJ56630 | Enable SSL status by default |
| IJ56636 | Large packet,1-socket,TCP RR throughput degradation on VEA. |
| IJ56662 | LLU fails in few scenarios |
| IJ56704 | 2544A_73H:bosinstlogsymbol reol failed libodm.a(shr.o |
| IJ56718 | Invalid memory write is causing memory corruption. |
| IJ56770 | Applications may core dump while performing LKU. |
| IJ56812 | VIOS physical media testing failed 2546A_73H |
Was this topic helpful?