Error description

  • HIPAA Compliance Check does not report custom Type 7 Exit
    failures in TAck or 999.
    

Local fix

  • ITXCQ - ITX00062606
    GM / GM
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender Pack for Healthcare HIPAA
    
    Problem Description:
    Not capturing Type7Exit failures in Tack JSon/999
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • If call to JEXIT or EXIT fails for Type 7 custom functions, the
    transaction will reject in the 999 and tack, and the error will
    be reported in the  compliance_check_summary.out file. No type
    tree changes needed, only compliance_check and
    hipaa_data_compliance maps updated.
    
    Applies to:
    Healthcare Pack HIPAA 10.2.3
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next fix pack or product release is available,
    check the IBM Transformation Extender product Release Notes
    page:
    https://www.ibm.com/support/pages/node/318755
    
    If a fix pack release is available, download it from Fix
    Central:
    http://www.ibm.com/support/fixcentral/
    
    If a new product release is available, download it from
    PassportAdvantage:
    https://www.ibm.com/software/passportadvantage/pao_customer.html
    
    
    If the fix pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a support Case:
    https://www.ibm.com/mysupport
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH63873

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-10-24

  • Closed date

    2024-12-10

  • Last modified date

    2025-02-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]

Document Information

Modified date:
22 February 2025