Error description

  • When using the IBM Sterling Transformation Extender (ITX)
    type tree importer against an Oracle database via a JDBC
    connection, the datatypes BINARY_FLOAT and BINARY_DOUBLE are
    supposed to be number but are imported as text.
    
    Here is an example table creation script :
    
    create table ibm_test_case (
       f1 BINARY_FLOAT,
       f2 BINARY_DOUBLE
    );
    
    When running the following import command :
    
    java -cp
    '<DTXHOME>\*;<DTXHOME>\tools\*;<DTXHOME>\extjar\Oracle\*'
    -Duser.language=en -Duser.country=US
    '-Djava.library.path=<DTXHOME>'
    com.hcl.hip.tools.adapterdriver.TreeImporter
    com.hcl.hip.adapters.m4jdbc '<FOLDER_PATH>\typetree.mtt' -url
    <connection_url> -driver oracle.jdbc.driver.OracleDriver -user
    <user> -password <password> -schema <schema> -query 'select *
    from ibm_test_case'
    
    The created type tree has Text items defined, instead of the
    expected Number items.
    

Local fix

  • ITXCQ - ITX00062624
    PB / GK
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender jdbc users reading data from Oracle
    DB, specifically including columns of two with data types
    BINARY_FLOAT and BINARY_DOUBLE
    
    Problem Description:
    JDBC - Oracle issue with BINARY_FLOAT and BINARY_DOUBLE
    
    Platforms Affected:
    All
    

Problem conclusion

  • The Oracle data types of BINARY_FLOAT and BINARY_DOUBLE have
    been internally mapped to the appropriate data types (32-bit
    Float and 64-bit Float respectively), so they will appear as the
    appropriate data types and not as text data types, in the
    imported schema.
    
    Applies to:
    10.1.2.1
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next fix pack or product release is available,
    check the IBM Transformation Extender product Release Notes
    page:
    https://www.ibm.com/support/pages/node/318755
    
    If a fix pack release is available, download it from Fix
    Central:
    http://www.ibm.com/support/fixcentral/
    
    If a new product release is available, download it from Passport
    Advantage:
    https://www.ibm.com/software/passportadvantage/pao_customer.html
    
    
    If the fix pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a support Case:
    https://www.ibm.com/mysupport
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH62976

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A12

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-08-28

  • Closed date

    2024-11-04

  • Last modified date

    2024-11-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A12"}]

Document Information

Modified date:
05 November 2024