IBM Support

IBM Virtual I/O Server support for Power Systems

Fix Readme


Abstract

Downloads for Workload Partition Manager for AIX

Content

Package information

PACKAGE: Update Release 2.2.5.10
IOSLEVEL: 2.2.5.10

VIOS level is NIM Master level must be equal to or higher than
Update Release 2.2.5.10 AIX 6100-09-08 or AIX 7100-04-03

In June 2015, VIOS introduces the minipack as a new service stream delivery vehicle as well as a change to the VIOS fix level numbering scheme. The VIOS "fix level" (the 4th number) has changed to two digits. For example, VIOS 2.2.5.1 has been changed to VIOS 2.2.5.10. Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.

General package notes

Be sure to heed all minimum space requirements before installing. For this version, target at least 900MB available in the '/' directory.

Review the list of fixes included in Update Release 2.2.5.10.

To take full advantage of all the function available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 2.2.5.10.

Microcode or system firmware downloads for Power Systems

The VIOS Update Release 2.2.5.10 includes the IVM code, but it will not be enabled on HMC-managed systems. Update Release 2.2.5.10, like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS.

Update Release 2.2.5.10 updates your VIOS partition to ioslevel 2.2.5.10. To determine if Update Release 2.2.5.10 is already installed, run the following command from the VIOS command line:

$ ioslevel

If Update Release 2.2.4.10 is installed, the command output is 2.2.5.10.

Known Capabilities and Limitations

The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.

Requirements for Shared Storage Pool

 

Limitations for Shared Storage Pool

Software Installation

SSP Configuration
Feature Min Max Special*
Number of VIOS Nodes in Cluster 1 16 24
Number of Physical Disks in Pool 1 1024
Number of Virtual Disks (LUs) Mappings in Pool 1 8192
Number of Client LPARs per VIOS node 1 250 400
Capacity of Physical Disks in Pool 10GB 16TB
Storage Capacity of Storage Pool 10GB 512TB
Capacity of a Virtual Disk (LU) in Pool 1GB 4TB
Number of Repository Disks 1 1
Capacity of Repository Disk 512MB 1016GB
Number of Client LPARs per Cluster 1 2000
 

*These features have special hardware requirements that must be met:

 

Other notes:


Network Configuration
Storage Configuration
Shared Storage Pool capabilities and limitations

Installation information

Pre-installation information and instructions

Please ensure that your rootvg contains at least 30GB and that there is at least 4GB free space before you attempt to update to Update Release 2.2.5.10. Run the lsvg rootvg command, and then ensure there is enough free space.

Example:

$ lsvg rootvg 
VOLUME GROUP:       rootvg                   VG IDENTIFIER:  00f6004600004c000000014306a3db3d
VG STATE:           active                   PP SIZE:        64 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      511 (32704 megabytes)
MAX LVs:            256                      FREE PPs:       64 (4096 megabytes)

LVs:                14                       USED PPs:       447 (28608 megabytes)
OPEN LVs:           12                       QUORUM:         2 (Enabled)
TOTAL PVs:          1                        VG DESCRIPTORS: 2
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         1                        AUTO ON:        yes
MAX PPs per VG:     32512                                     
MAX PPs per PV:     1016                     MAX PVs:        32
LTG size (Dynamic): 256 kilobyte(s)          AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
PV RESTRICTION:     none                     INFINITE RETRY: no

Upgrading from VIOS version lower than 2.1.0

If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version 2.1.0 using the Migration DVD. After the VIOS is at version 2.1.0, the Update/Fixpack 2.2.5.10 must be applied to bring the VIOS to the latest Fix Pack VIOS 2.2.5.10 level.

Note that with this Update Release 2.2.5.10, a single boot alternative to this multiple step process is available to NIM users. NIM users can update by creating a single, merged lpp_source that combines the contents of the Migration DVD with the contents of this Update Release 2.2.5.10.

A single, merged lpp_source is not supported for VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:

After the VIOS migration is complete, from 1.X to 2.X, you must set the Processor Folding, described here under "Migration DVD":

Instructions to disable Processor Folding are detailed at the link below.
See the "Migration DVD" section:

Upgrading from VIOS version 2.1.0 and above

The current level of VIOS must be between 2.2.1.1 and 2.2.4.x, you can put 2.2.5.10 in a location and do the update using updateios command.

Before installing the VIOS Update Release 2.2.5.10

The update could fail if there is a loaded media repository.

Checking for a loaded media repository

To check for a loaded media repository, and then unload it, follow these steps.

  1. To check for loaded images, run the following command:

    $ lsvopt
    The Media column lists any loaded media.

  2. To unload media images, run the following commands on all Virtual Target Devices that have loaded images.

    $ unloadopt -vtd <file-backed_virtual_optical_device >

  3. To verify that all media are unloaded, run the following command again.

    $ lsvopt
    The command output should show No Media for all VTDs.

Migrate Shared Storage Pool Configuration

The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 2.2.5.10 using rolling updates.

If your current VIOS is running with Shared Storage Pool from 2.2.1.1 or 2.2.1.3, the following information applies:

A cluster that is created and configured on VIOS Version 2.2.1.1 or 2.2.1.3 must be migrated to version 2.2.1.4 or 2.2.1.5 prior to utilizing rolling updates. This allows the user to keep their shared storage pool devices. When VIOS version is equal or greater than 2.2.1.4 and less than 2.2.5.10, the user needs to download 2.2.5.10 update images into a directory, then update the VIOS to Update Release 2.2.5.10 using rolling updates.

If your current VIOS is configured with Shared Storage Pool from 2.2.1.4 or later, the following information applies:

The rolling updates enhancement allows the user to apply Update Release 2.2.5.10 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

The VIOS SSP software monitors node status and will automatically upgrade the cluster to make use of the new capabilities when all the nodes in the cluster have been updated, "cluster -status -verbose" reports "ON_LEVEL" .


Installing the Update Release

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.

To verify the VIOS update files, follow these steps:

$ oem_setup_env
Create a link to openssl
# ln -s /usr/bin/openssl /usr/ios/utils/openssl
Verify the link to openssl was created
# ls -alL /usr/bin/openssl /usr/ios/utils/openssl
Both files should display similar owner and size
# exit

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

Note : While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

If your current level is between 2.2.1.1 and 2.2.2.1, you can directly apply 2.2.5.10 updates. This fixes an update problem with the builddate on bos.alt_disk_install.boot_images fileset.

If your current level is 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1, you need to run updateios command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.

Run the following command after the step of "$ updateios –accept –install –dev <directory_name >" completes.

$ updateios –accept –dev <directory_name >

Depending on the VIOs level, one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.

MISSING REQUISITES:

     X11.loc.fr_FR.base.lib 4.3.0.0        # Base Level Fileset
     bos.INed 6.1.6.0                      # Base Level Fileset
     bos.loc.pc.Ja_JP 6.1.0.0              # Base Level Fileset
     bos.loc.utf.EN_US 6.1.0.0             # Base Level Fileset
     bos.mls.rte 6.1.x.x                   # Base Level Fileset
     bos.mls.rte 6.1.9.200                 # Base Level Fileset or #Fileset Update
     bos.svprint.rte 6.1.9.200             # Fileset Update

Applying updates

WARNING: If the target node to be updated is part of a redundant VIOS pair, ensure that the VIOS partner node is fully operational before beginning to update the target node. NOTE that for VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

The current level of the VIOS must be 2.2.2.1 or later if you use the Share Storage Pool .

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.

    $ clstartstop -stop -n <cluster_name > -m <hostname >

  4. To apply updates from a directory on your local hard disk, follow the steps:
    • Create a directory on the Virtual I/O Server.
      $ mkdir <directory_name >
    • Using ftp, transfer the update file(s) to the directory you created.

    To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:

    • Mount the remote directory onto the Virtual I/O Server:
      $ mount remote_machine_name:directory /mnt

    The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:

    • Place the CD-ROM into the drive assigned to VIOS.
  5. Commit previous updates by running the updateios command

    $ updateios -commit

  6. Verify the updates files that were copied. This step can only be performed if the link to openssl was created.

    $ cp <directory_path >/ck_sum.bff /home/padmin
    $ chmod 755 </home/padmin>/ck_sum.bff
    $ ck_sum.bff <directory_path >
    If there are missing updates or incomplete downloads, an error message is displayed.

  7. Apply the update by running the updateios command

    $ updateios -accept -install -dev <directory_name >

  8. To load all changes, reboot the VIOS as user padmin .

    $ shutdown -restart

    Note: If shutdown –restart command failed, run swrole –PAdmin in order for padmin to set authorization and establish access to the shutdown command properly.

  9. If cluster services were stopped in step 3, restart cluster services.

    $ clstartstop -start -n <cluster_name > -m <hostname >

  10. Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now 2.2.5.10.

    $ ioslevel


Performing the necessary tasks after installation

Checking for an incomplete installation caused by a loaded media repository

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command:
$ lsrep

If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

Running the lsvopt command should show the media images.

Recovering from an incomplete installation caused by a loaded media repository

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

  1. Unload any media images

    $ unloadopt -vtd <file-backed_virtual_optical_device>

  2. Reinstall the ios.cli.rte fileset by running the following commands.

    To escape the restricted shell:
    $ oem_setup_env
    To install the failed fileset:
    # installp –Or –agX ios.cli.rte –d <device/directory >
    To return to the restricted shell:
    # exit

  3. Restart the VIOS.

    $ shutdown –restart

  4. Verify that the Media Repository is operational by running this command:

    $ lsrep

Additional information

NIM backup, install, and update information

Use of NIM to back up, install, and update the VIOS is supported.

For further assistance on the back up and install using NIM, refer to the NIM documentation.

Note : For install, always create the SPOT resource directly from the VIOS mksysb image. Do NOT update the SPOT from an LPP_SOURCE.

Use of NIM to update the VIOS is supported as follows:
Ensure that the NIM Master is at the appropriate level to support the VIOS image. Refer to the above table in the "Package information" section.

On the NIM Master, use the operation updateios to update the VIOS Server.

Sample: "nim –o updateios –a lpp_source=lpp_source1 ... ... ... "

For further assistance, refer to the NIM documentation.

On the NIM Master, use the operation alt_disk_install to update an alternate disk copy of the VIOS Server.

Sample:
"nim –o alt_disk_install –a source=rootvg –a disk=target_disk
–a fix_bundle=(Value) ... ... ...
"

For further assistance, refer to the NIM documentation.

If NIM is not used to update the VIOS, only the updateios or the alt_root_vg command from the padmin shell can be used to update the VIOS.

Installing the latest version of Tivoli TSM

This release of VIOS contains several enhancements. These enhancements are in the area of POWER virtualization. The following list provides the features of each element by product area.

Note: Version 6.1.0, the previous version of Tivoli TSM, is still shipped and installed from the VIOS installation DVD.

Tivoli TSM version 6.2.2

The Tivoli TSM filesets are now being shipped on the VIOS Expansion Pack, with the required GSKit8 libraries.

The following are sample installation instructions for the new Tivoli TSM filesets:

$ updateios -fs tivoli.tsm.client.api.32bit -dev /dev/cd0

NOTE: Any prerequisite filesets will be pulled in from the Expansion DVD, including for TSM the GSKit8.gskcrypt fileset.

  1. Insert the VIOS Expansion DVD into the DVD drive that is assigned to the VIOS partition.
  2. List Contents of the VIOS Expansion DVD.

    $ updateios -list -dev /dev/cd0
    Fileset Name
    GSKit8.gskcrypt32.ppc.rte 8.0.14.7
    GSKit8.gskcrypt64.ppc.rte 8.0.14.7
    GSKit8.gskssl32.ppc.rte 8.0.14.7
    GSKit8.gskssl64.ppc.rte 8.0.14.7
    ..
    tivoli.tsm.client.api.32bit 6.2.2.0 tivoli.tsm.client.api.64bit 6.2.2.0
    ..

  3. Install Tivoli TSM filesets.
  4. If needed, install additional TSM filesets.

    $ updateios -fs tivoli.tsm.client.ba.32bit -dev /dev/cd0

  5. Verify TSM installed by listing software installed.

    $ lssw
    Sample output:
    ..
    tivoli.tsm.client.api.32bit 6.2.2.0 CF TSM Client - Application Programming
    Interface

Fixes included in this release

List of fixes in 2.2.5.10
APAR Description
IV61308 HANG IN ELXENT_BUGOUT
IV65101 CAA MKWPAR -S CREATES WPAR WITH SPINNING CLCOMD
IV67228 SYSTEM CRASH DUE TO RECURSIVE LOCK IN FC5287 DRIVER
IV67308 VERY SLOW NETWORK THROUGHPUT FROM VIOC
IV69355 SEA LARGESEND CAN CAUSE TCP BAD HEADER OFFSET ON VIRTUAL CLIENT
IV69897 AIX /USR/SYSV/BIN/DF COMMAND REPORTS INCORRECT VALUES
IV70553 SAS CD DRIVE MAPPINGS CHANGED WHEN VIOS REBOOTED
IV70843 AIXPERT MAY ADD WRITE PERMISSION TO PROGRAMS
IV70899 FC1763/FC5899 supported port may become unresponsive
IV71204 rootcronjobck fails to handle symlink
IV71882 Invalidate on vid matched pvid of non-default trunk adapter.
IV71906 LVS AND VGS GET DISPLAYED WHEN THEY SHOULD BE HIDDEN.
IV72007 INCORRECT READ MAY OCCUR DURING JOINVG
IV72025 Assert in emfsc_free_cmd_elem
IV72133 caa: no gossip transmission on boot can lead to split-brain
IV72147 CFGIPSEC NOT PROPERLY HANDLING COMMENTS IN NEXTBOOT FILE
IV72562 SFW SFWCOM APPEARS UP TO CAA WHEN IT IS NOT FUNCTIONAL
IV72893 CLCOMD CAN USE TOO MUCH CPU WHEN AHAFS NOT ACCESSIBLE
IV73000 INCORRECT DETAIL IN VIOD_ALERT_EVENT IF CM DB FS CANNOT BE CHECK
IV73642 LSDEV -TYPE ENT4SEA EXCLUDES ROCE ADAPTER
IV73705 usrck does not catch non-executable shell
IV73716 partitions with more than 87,380 LMBs may crash
IV73758 EXECUTING STOPSRC -G IKE CAN HANG TMD
IV73765 alert -list option should list alerts of all tiers.
IV73767 Adapter in unknown state with nddctl -r
IV73768 EXTENDVG OF CONC VG MAY FORCE THE VG OFFLINE ON REMOTE NODE
IV73769 system crash in hd_reduce(), lvm layer
IV73770 joinvg in concurrent VG may put disks in missing
IV73838 caa: inactive node fails to generate remote node_up ahafs event
IV73951 I/O may hung during SCSI ACA Error Condition.
IV73952 cleanup SRC VIOS mappings after client lpar is remote restarted.
IV73954 system crash with livedump
IV73955 Unclear script callout errors
IV73976 A potential security issue exists CVE-2014-3566
IV73989 Node cle_globid range incorrect
IV73994 incorrect VPD information for Integrated ethernet adapter
IV74097 Slow NIM install/telnet/tcp connections
IV74184 The second port on Travis3-EN doesn't work
IV74329 CVE-2015-0261 and CVE-2015-2154 tcpdump vulnerablity fix
IV74484 ENTSTAT ON SEA FAILS WITH ENTSTAT_MODE ENVIRONEMT VARIABLE
IV74606 ALT_DISK_COPY ON 4K DISK TRIGGERS LVM_IO_FAIL
IV74650 caa: repository disk replacement may fail
IV74726 Etherchannel not recovering after port reset
IV74927 A potential security issue exists CVE-2015-2808
IV74946 clconfd lvm conflict with chrepos
IV75001 MIGRATEPV FAILURE MAY CAUSE IO HANG IN CONCURRENT VG
IV75057 rmvdev fails with an LU backed vtd.
IV75100 Restore seems to hang.
IV75102 SSP Lu's mapping goes missing after remote restart
IV75273 LSLDAP KEEPS ON FAILLING WHEN LDAP SERVER CLOSES CONNECTION
IV75290 Multiple client_partition entries cause mapping issues.
IV75364 CAA: UNEXPECTED START_NODE BY PEER NODE LEADS TO AST PANIC
IV75387 CAA: SYSTEM WILL CRASH IF GOSSIP PACKET HAS ID = 0
IV75388 updateios gives incorrect error codes/messages for some options
IV75480 LPM validation fails if some port bounce happens on SAN
IV75495 CODEGCHECK MIGHT FAIL WITH FALSE ERROR, DISPLAYING SCRIPTED
IV75538 caa: defined pv that matches repo pvid causes mkcluster to fail
IV75589 SYSTEM CRASHES IN ICMCLOSEQP1
IV75591 Resume can fail with HMC code HSCLA27F after validation pass.
IV75627 Cluster create could fail
IV75685 LPM can fail with HMC to MSP connection timed out error
IV75719 FCSTAT -N WWNXXXX FCS0 RETURNS 0 FOR FCSTAT OUTPUT
IV75738 LSSEC PERFORMANCE SUFFERS WHEN EFS IS ENABLED
IV75879 AIXPERT: RELATIVE CRON JOB SPECIFICATIONS MAY FAIL
IV75880 AIXPERT: FAILS TO HANDLE PARENT DIRECTORIES WITH ROOTCRNJOBCK
IV75883 DST with SRIOV dedicated failed in Stage 3
IV76033 Some SSP VTDs are not restored during cluster restore
IV76130 Invalid repository reserve policy not detected on remote nodes
IV76151 IKED LOOPS AND CAUSES CPU LOAD WHEN 0-BYTE DATAGRAM IS PRESENT
IV76158 SYSTEM CRASH AFTER RENDEV ON FCS ADAPTER
IV76194 VLAN ADAPTER ON PCIE2 4-PORT ADAPTER(10GBE SFP+) DROPS PACKETS
IV76204 ISCSI TOE SENDING IO TO WRONG TARGET
IV76214 VIO Change Mgmt daemon can core dump
IV76216 LUN discovery may fail during cfgmgr
IV76243 ETHERCHANNEL WITH CT3 ADAPTER MAY HANG
IV76254 Unable to start pool after a failed FG operation
IV76256 Unlock adapter is not required when lock did not happen earlier
IV76359 Do not remove adapter if suspend info is not updated
IV76508 EFSENABLE -D WRT LDAP OPERATION FAILS IN SOME SCENARIOS
IV76512 Packets with old MAC are received after changing MAC
IV76529 System crash while running hxecom with modified ent attributes
IV76530 VMLibrary size may be listed as zero
IV76538 SCTP heartbeats are not getting sent within RTO of the path
IV76591 0514-061 CANNOT FIND A CHILD DEVICE ERRORS ON FC ADAPTERS
IV76723 CAA UNICAST CLU: DMS ON LAST NODE DUE TO INCORRECT DPCOM STATE
IV76806 LSGROUP INCORRECTLY CACHES LDAP USER INFORMATION
IV76817 LPM validation or some VIOS function may give ODM lock errors
IV76821 'devrsrv' command to force clear SCSI-2 reserve on a vSCSI fails
IV77175 CAA: MERGE FAILURE DUE TO STALE JOIN_PENDING FLAG.
IV77179 viosecure command fails during rule failure with file option
IV77182 cluster Restore may fail in 1 node cluster with PowerVC
IV77183 System crash during adapter EEH recovery.
IV77471 Callback with NDD_LS_DOWN when EEH detected
IV77472 lnc2ent kdb command fails due to corrupted command table entry.
IV77475 ADD FOR POWERVC RESERVE_LOCK POLICY USING EMC 5.3.0.6 OR OLDER
IV77506 CACHEFS CRASHES IN CFIND()
IV77509 ABEND IN RESET_DECV
IV77510 SYSTEM CRASH IN REMOVING THE SEA ADAPTER BY RMDEV COMMAND
IV77522 Disks belonging to cluster are shown as free.
IV77529 DISK NORMAL OPEN FAILS WITH EACCES
IV77670 DIAG RETURNED 2E41-103: CHECKSUM VERIFICATION TEST FAILED
IV77687 ALLOW FC ATTRIBUTES TO BE SHOWN AND CHANGEABLE VIA SMIT
IV77744 Removing SEA device causes hang, SEA threads hang
IV77964 CAA: CHREPOS -C INCORRECTLY SAVES NODE_LOCAL VALUE TO REPO DISK
IV78144 cluster -status command does not always show pool status
IV78187 DSI IN ENTCORE_TX_SEND IN MLXENTDD
IV78360 LDAP USER HAS ADMCHG SET AFTER CHANGING OWN PASSWORD
IV78412 FAILURE OF VIOSBR (VIRTUALCFG) DOESN'T REMOVE WORKING FILES
IV78416 SECLDAPCLNTD INVALID CACHE ATTRIBUTE
IV78419 FC5899 IS MISSING SMIT PANEL FOR CHANGING MEDIA SPEED.
IV78420 NPIV adapter becomes unresponsive
IV78422 Repository Disk is shown as free when it is actually in use
IV78425 ROOTCRNJOBCK FAILS TO HANDLE RELATIVE SYMLINKS & SYMLINK CHAINS
IV78444 LOOPMOUNT COMMAND MAY FAIL FOR READ-ONLY NFS MOUNT
IV78453 IMPROVED DRIVER'S FAIRNESS ALGORITHM TO AVOID I/O STARVATION
IV78454 IMPROVED DRIVER'S FAIRNESS LOGIC TO AVOID I/O STARVATION
IV78502 LOOPING IN EFC_FREE_LOGIN_TBLE
IV78549 CRASH DUE TO BRKPOINT IN GXIB_RAS_REGISTER CALL DURING BOOT
IV78576 CRFS -A QUOTA=NO SHOULD HAVE FAILED DUE TO INVALID ATTRIBUTE
IV78682 Disk validation for LPM of NPIV client fails
IV78830 NPIV CLIENT LPAR REBOOT CAN HANG THE VIOS
IV78884 ALT_DISK_COPY MAY FAIL WHEN MOUNTING FILESYSTEMS
IV78895 NPIV Migration failed with Function npiv_phys_spt tried to
IV78897 LU-level validation for LPM fails with IBM i or Linux clients
IV78899 System crash in entcore_link_change_nic_callback()
IV78900 Removing certain virtual devices incorrectly fails.
IV79060 ABEND IN NMENT_FREE_RX
IV79066 CLMIGCHECK GIVES WARNING ON SYSLOG.CONF UPDATE
IV79067 CLMIGCHECK GIVES RESERVE ERROR ON REPOSITORY DISK
IV79069 VALID AIX LEVELS MIGHT BE INCORRECTLY IDENTIFIED AS INVALID.
IV79073 MISSING INFORMATION FROM CLMIGCHECK ERROR MESSAGE
IV79074 CLMIGCHECK FAILS IF NETSVC.CONF CONTAINS COMMENTED HOSTS LINES
IV79281 CLMIGCHECK MIGHT FAIL ON CLUSTERS WITH MORE THAN TWO NODES.
IV79303 IO.TEM CAN CRASH DURING THE PROCESSING OF FAILED ASYNCHRONOUS
IV79469 LU count listed in tier list output is incorrect.
IV79471 Some SSP VTDs missing after restore operation
IV79516 VKE_INFO QUEUE FULL ERROR DETAIL MESSAGE
IV79634 FAILED PATH ON A CLOSED DISK MAY NOT RECOVER AFTER DISK REOPEN
IV79658 LEVEL.OT MIGRATIONS FAIL IF ALL NODES NOT AT THE SAME CAA
IV79710 NIMADM FAILS WHEN MASTER IS BOOTED FROM BOS_HD5
IV79729 CLASS 3 NAMESERVER QUERY ODM SUPPORT FOR LEGACY FC ADAPTER
IV79874 SEA CONTROL CHANNEL & TRUNK VIRTUAL ADAPTER SHARE PVID CRASH
IV79991 FAST_FAIL MAY NOT WORK WHEN THE IMM_GID_PN ENABLED
IV80113 viosbr overwrites backups with frequency option.
IV80127 NIB ETHERCHANNEL WITH SR-IOV VF PORT PROBLEM
IV80151 SLOW HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS
IV80435 TRUSTCHK -U OUTPUT INVALID ATTRIBUTES FOR HARDLINKS & SYMLINKS
IV80569 MUSENTDD'S RECEIVE PATH HANGS WHEN IT RECEVIES CERTAIN SIZE PKT
IV80598 System crash after cachefs forced unmount
IV80689 LNCENTDD: MULTICAST ADDRS LOST WHEN PROMISCUOUS MODE TURNED OFF
IV80732 ISAKMPD CORE DUMPED IN SPI_PROTO DESTRUCTOR
IV80871 Race in lncentdd/lnc2entdd driver may make adapter unusable.
IV81016 When the catalog path is invalid artex commands coredump.
IV81022 ISAKMPD CORE DUMP AT COPY_REPL
IV81023 NETSTAT & ENTSTAT FOR ETHERCHANNELS WITH SRIOV DO NOT SHOW MAC
IV81024 MKFS -V JFS2 -O LOG=INLINE /DEV/LOOP0 WITH IV79296 INSTALLED
IV81223 HMC reports that VIOS is busy and not responding to queries
IV81241 MELLANOX V2 DRIVER LOGS LINK UP AND LINK DOWN DURING REBOOT
IV81297 VIO CLIENT CRASHES IN DISK DRIVER DURING LPM WITH GPFS AND PR SH
IV81352 VM deploy fails when using NIC adapters
IV81454 DSI IN RRHBA_QUERY_NIC
IV81462 DF AND LSFS MAY LIST THE WRONG FILESYSTEM
IV81739 LPM: MIGMGR(FIND_DEVICES -T VETH) RC=8 ON DESTINATION VIOS
IV81756 VIOS may crash after using SSP image management in IBM Director
IV81820 CM ATTRIBUTE: MISSING MPIOALGORITHM FOR POWERPATH PVS
IV81839 Virtual tape devices do not configure after upgrading VIOS
IV81840 DEVICE IPSEC_V4 MAY COME UP DEFINED AT BOOT
IV81854 Some objects may be missing in list presented to HMC
IV81936 May lose access to one or more NPIV disks
IV81937 Segfault may occur in ioscli vg or lv related commands.
IV81967 UPDATEIOS:REMOVING INSTALLED EFIX FAILS DUE TO GARBAGE CHARACTER
IV82022 LU -RESIZE NOT RECOGNIZED ON CLIENT AND SCF LOCK ERROR
IV82080 SEGMENTATION FAULT IN RULESCFGSET IF MOTD BIGGER THAN 1024 CHARS
IV82145 IPREPORT DOES NOT DISPLAY TCP OPTION 14 (TCPOPT_ALTCKSUM)
IV82194 CRASH DURING VIOENT CALLBACK WHEN USED WITH ETHERCHANNEL
IV82195 SR-IOV TX_TIMEOUT DEFAULTS TO 30 SECONDS
IV82197 LPM-ED CLIENTS TEMPORARILY LOOSE CONNECTIVTY DUE TO RARPS.
IV82449 VIRTUAL ETHERNET ADAPTER DRIVER MAY GOES INTO DEAD STATE.
IV82461 VIOS may rarely crash during LUN-level validation for LPM
IV82463 Adapters using lncentdd driver may log EEH as permanent Error
IV82577 UNMIRRORVG ROOTVG MAY HANG WITH FW-ASSISTED DUMP & HD6
IV82579 SLOW HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS
IV82596 SYN NOT RECEIVED WHEN VEA CLIENT TURN OFF CHECKSUM OFFLOAD
IV82627 CAA(MULTICAST): A NODE MAY NOT SEE A REBOOTED NODE AS UP
IV82728 SECONDARY GROUP NOT DETERMINED FOR OLDER NETIQ LDAP SERVERS
IV82752 PACKET ADJUSTED MULTIPLE TIMES BY RRHBADD DRIVER
IV82795 VIOS CRASH WHEN CREATING SEA IN LOW MEMORY CONDITION
IV82983 viosbr -restore not restoring other nodes except initiator node
IV83078 VIOS may crash when doing LUN-level validation for LPM
IV83079 trustchk error on /var/adm/cron/log after migration
IV83100 Handle pv backed virtual target devices during suspend operation
IV83121 After viosecure -undo, viosecure -view reports error
IV83143 I/O HANG IN EFC_FREE_LOGIN_TBLE
IV83212 HOSTNAME ISSUES PREVENT NODE FROM JOINING THE CAA CLUSTER
IV83291 NPIV client hang when cancel command fails
IV83544 TRUSTCHK -U FAILS FOR ALLOW_OWNER ALLOW_GROUP ALLOW_ALL
IV83615 ROLLING UPGRADE FROM DBV3 TO V4 FAILS
IV83637 DRW_LOCK_WRITE() BLOCKING READ THREADS CAUSE HANG.
IV83875 SECLDAPCLNTD MAY FAIL TO HANDLE LONG PASSWORD HASH STRINGS
IV84242 VM validation fails if nondisk type LU configured to NPIV client
IV84341 WRONG UDP FILTERS ADDED BY AIXPERT IPSECSHUNPORTS
IV84449 TCBCK -Y ALL IS RUN AT FIRSTBOOT FROM ALTERNATE DISK IN TCB ENV
IV84470 CRASH DUE TO POSSIBLE MEMORY LEAK IN CAA
IV84478 MULTIPLE DUPLICATE PDAT ODM ENTRIES FOR MPIOAPDISK
IV84555 MAC/VLAN ACL status incorrectly displayed when PVID enabled.
IV84636 BOOTPD DOESN'T FIND ROUTE WITH MANY NETWORK INTERFACES IN USE
IV84649 LPM fails when disk's unique_id has special characters
IV84661 Removing interface,when upgrading FW.Move hang state for FC#EN0H
IV84677 CACHE METHOD DOESN'T SET PROD FLAG CORRECTLY.
IV84704 LARGE RECEIVE ON VIOS IS SLOW WHEN VIO CLIENT HAS CHKSUM OFF
IV84767 FAILOVER HAPPENS ON 802.3AD ETHERCHANNEL WHILE REBOOT
IV84769 PANIC IN TSTART VIA SEAHA_PROCESS_DSCV_INIT
IV84776 NODE CRASHED
IV84833 System crash issuing slot reset after returning EEH Suspend busy
IV84889 CAA UNUSABLE NET_ADDR ON REPOSITORY DISK AFTER CHANGE BOOT IP
IV84953 CM daemon runs out of memory and thus restarts.
IV84985 EEH Resume failure can cause restart to set invalid device state
IV85080 Crash due to race condition of between DEAD and Close
IV85145 CONSTANT DISK_ERR4 ERRORS FOR INTERNAL SCSI DISKS IF HEALTH CHEC
IV85215 RDMAcore returns error if suspend is called more than once.
IV85255 ADDING AUDIT CONFIG FULLPATH OPTION
IV85311 Promiscuous or All mcast flags still shown as set after a close
IV85393 system crash running get_adapter with trace level >= 5
IV85395 alt_disk_mksysb hangs without the absolute path to device
IV85423 MOUNT MAY FAIL REPORTING MEDIA IS NOT FORMATTED
IV85460 ABEND_TRAP FROM CLOCK
IV85508 caa: core dump if netmon.cf entries are defined
IV85593 NFS3 OPEN FAILURE AFTER NFS3 OPEN WITH O_DIRECT AND O_CIO FAILS
IV85670 VARYONVG HANG IN SCSIDISK_CLOSE() DURING BOOT
IV85676 Repos DOWN event on create led to crash
IV85884 EEH Exit after performing Hot/Fundamental reset after FW update
IV85886 AIXPERT PREREQS ARE NOT MAINTAINED AFTER APPLYING RULES
IV85888 caa: clcomd fails to handle local internal bound ip address
IV85891 DSI CRASH IN VIOENT_OUTPUT
IV85895 ECH_CANNOT_FAILOVER ERROR WHEN REBOOTING
IV86129 Fix CVE-2015-7575 in imap,pop3
IV86237 Possible race condition between ctrc suspend and trace operation
IV86408 VIOS fails with adapter in use message during LPM
IV86523 SYSTEM MAY HANG WHEN UPGRADING OR REMOVING BOS.RTE.SECURITY
IV86535 system crash while using adapter with FC#EN0S and EN0W
IV86538 SYNCLVODM IS SLOW WHEN THERE ARE MANY DISKS CONFIGURED
IV86577 System crash due to stack overflow when errlogging on slih path
IV86666 mkvopt command allows vopt device names with special characters
IV86678 PACKETS ARE SEEN TWICE IN IPTRACE
IV86679 parallel importpv and reboot fails the importpv operation.
IV86684 handle large image file copies
IV86792 Removal of more than one node from a cluster was giving error
IV86794 Rolling Upgrade does not finish
IV86861 ERROR MESSAGE DURING REPLACEPV NOT RELEVANT
IV87015 clmigcheck fails to find any shared disks
IV87020 VM deploy fails with VIOS_VSCSI_HOST err (relative port id=0)
IV87053 IPTRACE -L DOES NOT ROTATE LOGFILE IF LOGSIZE MORE THAN 2GB
IV87134 VIOS crash in target_cdt_add
IV87309 CRASH IN XHCI_OPEN WHEN ACCESSING /DEV/USBHC0
IV87315 CAA CLCONFD CORE PTH_USCHED._USCHED_DISPATCH_FRONT._CHK_RESTART
IV87496 The validation fails, while migrating the client partitition
IV87670 IMPROVE HANDLING OF UNDETERMINED DISK ERRORS IN MPIO CONFIGURATI
IV87701 Restore fails for the max_transfer size of the hdisks.
IV87704 LPM will not start with a VASI Open error
IV87734 CLUSTER HEARTBEAT SETTINGS SMIT MENU MAY SHOW VALUE AS ZERO
IV87738 cluster backup through viosbr command gives segmentation fault.
IV87742 Do not use FC port if all NPIV ports are in use
IV87743 Displaying cluster status during cluster node out of network
IV87775 IMPROVE HANDLING OF ABORTED COMMANDS
IV87913 SYSTEM CRASH WITH NPIV_VALIDATE_DO_PORT_LOGIN
IV87957 FC5899 ENTSTAT PRINTS 1818495488 FOR BAD PACKET COUNT IN NON-C
IV87958 DURING FCS ADAPTER RECOVERY NODE CAN CRASH.
IV87981 A POTENTIAL SECURITY ISSUE EXISTS
IV88287 INACTIVE LPM MAY FAIL DUE TO MISSING CAPABILITIES
IV88351 Timing related deadlock issue in LPM
IV88688 RECREATEVG -D NEEDS BETTER USAGE DOCUMENTATION.
IV88719 DSI IN SEADD:SEA_VIRT_INPUT_POST_Q
IV88727 RULESCFGSET MAY ADD GARBAGE LINES IN MOTD FILE
IV89148 Potential cluster hang during svCollect.
IV90068 PCM SSP data collection status may not be updated properly
IV90482 bos.esagent fails to update during VIOS 2.2.5.10 SP install

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPHKW","label":"PowerVM Virtual I\/O Server"},"Component":"","Platform":[{"code":"PF002","label":"AIX"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date:
19 February 2022

UID