Fix Readme
Abstract
Downloads for Workload Partition Manager for AIX
Content
IBM PowerVM Virtual I/O Server
Contents
This Readme contains installation and other information about VIOS Update Release 2.2.5.10
Package information
PACKAGE: Update Release 2.2.5.10
IOSLEVEL: 2.2.5.10
| VIOS level is | NIM Master level must be equal to or higher than |
|---|---|
| Update Release 2.2.5.10 | AIX 6100-09-08 or AIX 7100-04-03 |
In June 2015, VIOS introduces the minipack as a new service stream delivery vehicle as well as a change to the VIOS fix level numbering scheme. The VIOS "fix level" (the 4th number) has changed to two digits. For example, VIOS 2.2.5.1 has been changed to VIOS 2.2.5.10. Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.
General package notes
Be sure to heed all minimum space requirements before installing. For this version, target at least 900MB available in the '/' directory.
Review the list of fixes included in Update Release 2.2.5.10.
To take full advantage of all the function available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 2.2.5.10.
Microcode or system firmware downloads for Power Systems
The VIOS Update Release 2.2.5.10 includes the IVM code, but it will not be enabled on HMC-managed systems. Update Release 2.2.5.10, like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS.
Update Release 2.2.5.10 updates your VIOS partition to ioslevel 2.2.5.10. To determine if Update Release 2.2.5.10 is already installed, run the following command from the VIOS command line:
$ ioslevel
If Update Release 2.2.4.10 is installed, the command output is 2.2.5.10.
Known Capabilities and Limitations
The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.
Requirements for Shared Storage Pool
- Platforms: POWER6 and later (includes Blades), IBM PureFlex Systems (Power Compute Nodes only)
- System requirements per SSP node:
- Minimum CPU: 1 CPU of guaranteed entitlement
- Minimum memory: 4GB
- Storage requirements per SSP cluster (minimum): 1 fiber-channel attached disk for repository, 1 GB
- At least 1 fiber-channel attached disk for data, 10GB
Limitations for Shared Storage Pool
Software Installation
- All VIOS nodes must be at version 2.2.1.3 or later.
- When installing updates for VIOS Update Release 2.2.5.10 participating in a Shared Storage Pool, the Shared Storage Pool Services must be stopped on the node being upgraded.
- In order to take advantage of the new SSP features in 2.2.4.00 (including improvements in the min/max levels), all nodes in the SSP cluster must be at 2.2.4.00.
| Feature | Min | Max | Special* |
|---|---|---|---|
| Number of VIOS Nodes in Cluster | 1 | 16 | 24 |
| Number of Physical Disks in Pool | 1 | 1024 | |
| Number of Virtual Disks (LUs) Mappings in Pool | 1 | 8192 | |
| Number of Client LPARs per VIOS node | 1 | 250 | 400 |
| Capacity of Physical Disks in Pool | 10GB | 16TB | |
| Storage Capacity of Storage Pool | 10GB | 512TB | |
| Capacity of a Virtual Disk (LU) in Pool | 1GB | 4TB | |
| Number of Repository Disks | 1 | 1 | |
| Capacity of Repository Disk | 512MB | 1016GB | |
| Number of Client LPARs per Cluster | 1 | 2000 |
*These features have special hardware requirements that must be met:
- Over 16 VIOS Nodes requires that the SYSTEM (metadata) tier contains only SSD storage.
- Over 250 Client LPARs per VIOS requires each VIOS have at least 4 CPUs and 8 GM memory.
Other notes:
- Maximum number of physical volumes that can be added to or replaced from a pool at one time: 64
- The Shared Storage Pool cluster name must be less than 63 characters long.
- The Shared Storage Pool pool name must be less than 127 characters long.
- The maximum supported LU size is 4TB, however, for high I/O workloads it is recommended to use multiple smaller LUs as it will improve performance. For example, using 16 separate 16GB LUs would yield better performance than a single 256GB LU for applications that perform reads and writes to a variety of storage locations concurrently.
- The size of the /var drive should be greater than or equal to 3GB to ensure proper logging.
Network Configuration
- Uninterrupted network connectivity is required for operation. i.e. The network interface used for Shared Storage Pool configuration must be on a highly reliable network which is not congested.
- A Shared Storage Pool configuration can use IPV4 or IPV6, but not a combination of both.
- A Shared Storage Pool configuration should configure the TCP/IP resolver routine for name resolution to resolve host names locally first, and then use the DNS. For step by step instructions, refer to the TCP/IP name resolution documentation in the IBM Knowledge Center.
- The forward and reverse lookup should resolve to the IP address/hostname that is used for Shared Storage Pool configuration.
- It is recommended that the VIOSs that are part of the Shared Storage Pool configuration keep their clocks synchronized.
Storage Configuration
- Virtual SCSI devices provisioned from the Shared Storage Pool may drive higher CPU utilization than the classic Virtual SCSI devices.
- Using SCSI reservations (SCSI Reserve/Release and SCSI-3 Reserve) for fencing physical disks in the Shared Storage pool is not supported.
- SANCOM will not be supported in a Shared Storage Pool environment.
Shared Storage Pool capabilities and limitations
- On the client LPAR Virtual SCSI disk is the only peripheral device type supported by SSP at this time.
- When creating Virtual SCSI Adapters for VIOS LPARs, the option "Any client partition can connect" is not supported.
- VIOSs configured for SSP require that Shared Ethernet Adapter(s) (SEA) be setup for Threaded mode (the default mode). SEA in Interrupt Mode is not supported within SSP.
- VIOSs configured for SSP can be used as a Paging Space Partition (PSP), but the storage for the PSP paging spaces must come from logical devices not within a Shared Storage Pool. Using a VIOS SSP logical unit (LU) as an Active Memory Sharing (AMS) paging space or as the suspend/resume file is not supported.
Installation information
Pre-installation information and instructions
Please ensure that your rootvg contains at least 30GB and that there is at least 4GB free space before you attempt to update to Update Release 2.2.5.10. Run the lsvg rootvg command, and then ensure there is enough free space.
Example:
$ lsvg rootvg VOLUME GROUP: rootvg VG IDENTIFIER: 00f6004600004c000000014306a3db3d VG STATE: active PP SIZE: 64 megabyte(s) VG PERMISSION: read/write TOTAL PPs: 511 (32704 megabytes) MAX LVs: 256 FREE PPs: 64 (4096 megabytes) LVs: 14 USED PPs: 447 (28608 megabytes) OPEN LVs: 12 QUORUM: 2 (Enabled) TOTAL PVs: 1 VG DESCRIPTORS: 2 STALE PVs: 0 STALE PPs: 0 ACTIVE PVs: 1 AUTO ON: yes MAX PPs per VG: 32512 MAX PPs per PV: 1016 MAX PVs: 32 LTG size (Dynamic): 256 kilobyte(s) AUTO SYNC: no HOT SPARE: no BB POLICY: relocatable PV RESTRICTION: none INFINITE RETRY: no
Upgrading from VIOS version lower than 2.1.0
If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version 2.1.0 using the Migration DVD. After the VIOS is at version 2.1.0, the Update/Fixpack 2.2.5.10 must be applied to bring the VIOS to the latest Fix Pack VIOS 2.2.5.10 level.
Note that with this Update Release 2.2.5.10, a single boot alternative to this multiple step process is available to NIM users. NIM users can update by creating a single, merged lpp_source that combines the contents of the Migration DVD with the contents of this Update Release 2.2.5.10.
A single, merged lpp_source is not supported for VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:
SDD and SDDPCM migration procedures when migrating VIOS from version 1.x to version 2.x
After the VIOS migration is complete, from 1.X to 2.X, you must set the Processor Folding, described here under "Migration DVD":
Instructions to disable Processor Folding are detailed at the link below.
See the "Migration DVD" section:
Virtual I/O Server support for Power Systems
Upgrading from VIOS version 2.1.0 and above
The current level of VIOS must be between 2.2.1.1 and 2.2.4.x, you can put 2.2.5.10 in a location and do the update using updateios command.
Before installing the VIOS Update Release 2.2.5.10
The update could fail if there is a loaded media repository.
Checking for a loaded media repository
To check for a loaded media repository, and then unload it, follow these steps.
- To check for loaded images, run the following command:
$ lsvopt
The Media column lists any loaded media. - To unload media images, run the following commands on all Virtual Target Devices that have loaded images.
$ unloadopt -vtd <file-backed_virtual_optical_device >
- To verify that all media are unloaded, run the following command again.
$ lsvopt
The command output should show No Media for all VTDs.
Migrate Shared Storage Pool Configuration
The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 2.2.5.10 using rolling updates.
If your current VIOS is running with Shared Storage Pool from 2.2.1.1 or 2.2.1.3, the following information applies:
A cluster that is created and configured on VIOS Version 2.2.1.1 or 2.2.1.3 must be migrated to version 2.2.1.4 or 2.2.1.5 prior to utilizing rolling updates. This allows the user to keep their shared storage pool devices. When VIOS version is equal or greater than 2.2.1.4 and less than 2.2.5.10, the user needs to download 2.2.5.10 update images into a directory, then update the VIOS to Update Release 2.2.5.10 using rolling updates.
If your current VIOS is configured with Shared Storage Pool from 2.2.1.4 or later, the following information applies:
The rolling updates enhancement allows the user to apply Update Release 2.2.5.10 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.
To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:
- All VIOS logical partitions must have VIOS Update Release version 2.2.1.4 or later installed. After the update, you can verify that the logical partitions have the new level of software installed by typing the cluster -status -verbose command from the VIOS command line. In the Node Upgrade Status field, if the status of the VIOS logical partition is displayed as UP_LEVEL , the software level in the logical partition is higher than the software level in the cluster. If the status is displayed as ON_LEVEL , the software level in the logical partition and the cluster is the same.
- All VIOS logical partitions must be running. If any VIOS logical partition in the cluster is not running, the cluster cannot be upgraded to use the new SSP capabilities.
The VIOS SSP software monitors node status and will automatically upgrade the cluster to make use of the new capabilities when all the nodes in the cluster have been updated, "cluster -status -verbose" reports "ON_LEVEL" .
Installing the Update Release
There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.
To verify the VIOS update files, follow these steps:
$ oem_setup_env
Create a link to openssl
# ln -s /usr/bin/openssl /usr/ios/utils/openssl
Verify the link to openssl was created
# ls -alL /usr/bin/openssl /usr/ios/utils/openssl
Both files should display similar owner and size
# exit
Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.
If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.
Note : While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.
If your current level is between 2.2.1.1 and 2.2.2.1, you can directly apply 2.2.5.10 updates. This fixes an update problem with the builddate on bos.alt_disk_install.boot_images fileset.
If your current level is 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1, you need to run updateios command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.
Run the following command after the step of "$ updateios –accept –install –dev <directory_name >" completes.
$ updateios –accept –dev <directory_name >
Depending on the VIOs level, one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.
MISSING REQUISITES:
X11.loc.fr_FR.base.lib 4.3.0.0 # Base Level Fileset
bos.INed 6.1.6.0 # Base Level Fileset
bos.loc.pc.Ja_JP 6.1.0.0 # Base Level Fileset
bos.loc.utf.EN_US 6.1.0.0 # Base Level Fileset
bos.mls.rte 6.1.x.x # Base Level Fileset
bos.mls.rte 6.1.9.200 # Base Level Fileset or #Fileset Update
bos.svprint.rte 6.1.9.200 # Fileset Update
Applying updates
WARNING: If the target node to be updated is part of a redundant VIOS pair, ensure that the VIOS partner node is fully operational before beginning to update the target node. NOTE that for VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.
The current level of the VIOS must be 2.2.2.1 or later if you use the Share Storage Pool .
- Log in to the VIOS as the user padmin.
- If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
- If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.
$ clstartstop -stop -n <cluster_name > -m <hostname >
- To apply updates from a directory on your local hard disk, follow the steps:
- Create a directory on the Virtual I/O Server.
$ mkdir <directory_name > - Using ftp, transfer the update file(s) to the directory you created.
To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:
- Mount the remote directory onto the Virtual I/O Server:
$ mount remote_machine_name:directory /mnt
The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:
- Place the CD-ROM into the drive assigned to VIOS.
- Create a directory on the Virtual I/O Server.
- Commit previous updates by running the updateios command
$ updateios -commit
- Verify the updates files that were copied. This step can only be performed if the link to openssl was created.
$ cp <directory_path >/ck_sum.bff /home/padmin
$ chmod 755 </home/padmin>/ck_sum.bff
$ ck_sum.bff <directory_path >
If there are missing updates or incomplete downloads, an error message is displayed. - Apply the update by running the updateios command
$ updateios -accept -install -dev <directory_name >
- To load all changes, reboot the VIOS as user padmin .
$ shutdown -restart
Note: If shutdown –restart command failed, run swrole –PAdmin in order for padmin to set authorization and establish access to the shutdown command properly.
- If cluster services were stopped in step 3, restart cluster services.
$ clstartstop -start -n <cluster_name > -m <hostname >
- Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now 2.2.5.10.
$ ioslevel
Performing the necessary tasks after installation
Checking for an incomplete installation caused by a loaded media repository
After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.
Check the Media Repository by running this command:
$ lsrep
If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.
Running the lsvopt command should show the media images.
Recovering from an incomplete installation caused by a loaded media repository
To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:
- Unload any media images
$ unloadopt -vtd <file-backed_virtual_optical_device>
- Reinstall the ios.cli.rte fileset by running the following commands.
To escape the restricted shell:
$ oem_setup_env
To install the failed fileset:
# installp –Or –agX ios.cli.rte –d <device/directory >
To return to the restricted shell:
# exit - Restart the VIOS.
$ shutdown –restart
- Verify that the Media Repository is operational by running this command:
$ lsrep
Additional information
NIM backup, install, and update information
Use of NIM to back up, install, and update the VIOS is supported.
For further assistance on the back up and install using NIM, refer to the NIM documentation.
Note : For install, always create the SPOT resource directly from the VIOS mksysb image. Do NOT update the SPOT from an LPP_SOURCE.
Use of NIM to update the VIOS is supported as follows:
Ensure that the NIM Master is at the appropriate level to support the VIOS image. Refer to the above table in the "Package information" section.
On the NIM Master, use the operation updateios to update the VIOS Server.
Sample: "nim –o updateios –a lpp_source=lpp_source1 ... ... ... "
For further assistance, refer to the NIM documentation.
On the NIM Master, use the operation alt_disk_install to update an alternate disk copy of the VIOS Server.
Sample:
"nim –o alt_disk_install –a source=rootvg –a disk=target_disk
–a fix_bundle=(Value) ... ... ... "
For further assistance, refer to the NIM documentation.
If NIM is not used to update the VIOS, only the updateios or the alt_root_vg command from the padmin shell can be used to update the VIOS.
Installing the latest version of Tivoli TSM
This release of VIOS contains several enhancements. These enhancements are in the area of POWER virtualization. The following list provides the features of each element by product area.
Note: Version 6.1.0, the previous version of Tivoli TSM, is still shipped and installed from the VIOS installation DVD.
Tivoli TSM version 6.2.2
The Tivoli TSM filesets are now being shipped on the VIOS Expansion Pack, with the required GSKit8 libraries.
The following are sample installation instructions for the new Tivoli TSM filesets:
$ updateios -fs tivoli.tsm.client.api.32bit -dev /dev/cd0
NOTE: Any prerequisite filesets will be pulled in from the Expansion DVD, including for TSM the GSKit8.gskcrypt fileset.
- Insert the VIOS Expansion DVD into the DVD drive that is assigned to the VIOS partition.
- List Contents of the VIOS Expansion DVD.
$ updateios -list -dev /dev/cd0
Fileset Name
GSKit8.gskcrypt32.ppc.rte 8.0.14.7
GSKit8.gskcrypt64.ppc.rte 8.0.14.7
GSKit8.gskssl32.ppc.rte 8.0.14.7
GSKit8.gskssl64.ppc.rte 8.0.14.7
..
tivoli.tsm.client.api.32bit 6.2.2.0 tivoli.tsm.client.api.64bit 6.2.2.0
.. - Install Tivoli TSM filesets.
- If needed, install additional TSM filesets.
$ updateios -fs tivoli.tsm.client.ba.32bit -dev /dev/cd0
- Verify TSM installed by listing software installed.
$ lssw
Sample output:
..
tivoli.tsm.client.api.32bit 6.2.2.0 CF TSM Client - Application Programming
Interface
Fixes included in this release
| APAR | Description |
|---|---|
| IV61308 | HANG IN ELXENT_BUGOUT |
| IV65101 | CAA MKWPAR -S CREATES WPAR WITH SPINNING CLCOMD |
| IV67228 | SYSTEM CRASH DUE TO RECURSIVE LOCK IN FC5287 DRIVER |
| IV67308 | VERY SLOW NETWORK THROUGHPUT FROM VIOC |
| IV69355 | SEA LARGESEND CAN CAUSE TCP BAD HEADER OFFSET ON VIRTUAL CLIENT |
| IV69897 | AIX /USR/SYSV/BIN/DF COMMAND REPORTS INCORRECT VALUES |
| IV70553 | SAS CD DRIVE MAPPINGS CHANGED WHEN VIOS REBOOTED |
| IV70843 | AIXPERT MAY ADD WRITE PERMISSION TO PROGRAMS |
| IV70899 | FC1763/FC5899 supported port may become unresponsive |
| IV71204 | rootcronjobck fails to handle symlink |
| IV71882 | Invalidate on vid matched pvid of non-default trunk adapter. |
| IV71906 | LVS AND VGS GET DISPLAYED WHEN THEY SHOULD BE HIDDEN. |
| IV72007 | INCORRECT READ MAY OCCUR DURING JOINVG |
| IV72025 | Assert in emfsc_free_cmd_elem |
| IV72133 | caa: no gossip transmission on boot can lead to split-brain |
| IV72147 | CFGIPSEC NOT PROPERLY HANDLING COMMENTS IN NEXTBOOT FILE |
| IV72562 | SFW SFWCOM APPEARS UP TO CAA WHEN IT IS NOT FUNCTIONAL |
| IV72893 | CLCOMD CAN USE TOO MUCH CPU WHEN AHAFS NOT ACCESSIBLE |
| IV73000 | INCORRECT DETAIL IN VIOD_ALERT_EVENT IF CM DB FS CANNOT BE CHECK |
| IV73642 | LSDEV -TYPE ENT4SEA EXCLUDES ROCE ADAPTER |
| IV73705 | usrck does not catch non-executable shell |
| IV73716 | partitions with more than 87,380 LMBs may crash |
| IV73758 | EXECUTING STOPSRC -G IKE CAN HANG TMD |
| IV73765 | alert -list option should list alerts of all tiers. |
| IV73767 | Adapter in unknown state with nddctl -r |
| IV73768 | EXTENDVG OF CONC VG MAY FORCE THE VG OFFLINE ON REMOTE NODE |
| IV73769 | system crash in hd_reduce(), lvm layer |
| IV73770 | joinvg in concurrent VG may put disks in missing |
| IV73838 | caa: inactive node fails to generate remote node_up ahafs event |
| IV73951 | I/O may hung during SCSI ACA Error Condition. |
| IV73952 | cleanup SRC VIOS mappings after client lpar is remote restarted. |
| IV73954 | system crash with livedump |
| IV73955 | Unclear script callout errors |
| IV73976 | A potential security issue exists CVE-2014-3566 |
| IV73989 | Node cle_globid range incorrect |
| IV73994 | incorrect VPD information for Integrated ethernet adapter |
| IV74097 | Slow NIM install/telnet/tcp connections |
| IV74184 | The second port on Travis3-EN doesn't work |
| IV74329 | CVE-2015-0261 and CVE-2015-2154 tcpdump vulnerablity fix |
| IV74484 | ENTSTAT ON SEA FAILS WITH ENTSTAT_MODE ENVIRONEMT VARIABLE |
| IV74606 | ALT_DISK_COPY ON 4K DISK TRIGGERS LVM_IO_FAIL |
| IV74650 | caa: repository disk replacement may fail |
| IV74726 | Etherchannel not recovering after port reset |
| IV74927 | A potential security issue exists CVE-2015-2808 |
| IV74946 | clconfd lvm conflict with chrepos |
| IV75001 | MIGRATEPV FAILURE MAY CAUSE IO HANG IN CONCURRENT VG |
| IV75057 | rmvdev fails with an LU backed vtd. |
| IV75100 | Restore seems to hang. |
| IV75102 | SSP Lu's mapping goes missing after remote restart |
| IV75273 | LSLDAP KEEPS ON FAILLING WHEN LDAP SERVER CLOSES CONNECTION |
| IV75290 | Multiple client_partition entries cause mapping issues. |
| IV75364 | CAA: UNEXPECTED START_NODE BY PEER NODE LEADS TO AST PANIC |
| IV75387 | CAA: SYSTEM WILL CRASH IF GOSSIP PACKET HAS ID = 0 |
| IV75388 | updateios gives incorrect error codes/messages for some options |
| IV75480 | LPM validation fails if some port bounce happens on SAN |
| IV75495 | CODEGCHECK MIGHT FAIL WITH FALSE ERROR, DISPLAYING SCRIPTED |
| IV75538 | caa: defined pv that matches repo pvid causes mkcluster to fail |
| IV75589 | SYSTEM CRASHES IN ICMCLOSEQP1 |
| IV75591 | Resume can fail with HMC code HSCLA27F after validation pass. |
| IV75627 | Cluster create could fail |
| IV75685 | LPM can fail with HMC to MSP connection timed out error |
| IV75719 | FCSTAT -N WWNXXXX FCS0 RETURNS 0 FOR FCSTAT OUTPUT |
| IV75738 | LSSEC PERFORMANCE SUFFERS WHEN EFS IS ENABLED |
| IV75879 | AIXPERT: RELATIVE CRON JOB SPECIFICATIONS MAY FAIL |
| IV75880 | AIXPERT: FAILS TO HANDLE PARENT DIRECTORIES WITH ROOTCRNJOBCK |
| IV75883 | DST with SRIOV dedicated failed in Stage 3 |
| IV76033 | Some SSP VTDs are not restored during cluster restore |
| IV76130 | Invalid repository reserve policy not detected on remote nodes |
| IV76151 | IKED LOOPS AND CAUSES CPU LOAD WHEN 0-BYTE DATAGRAM IS PRESENT |
| IV76158 | SYSTEM CRASH AFTER RENDEV ON FCS ADAPTER |
| IV76194 | VLAN ADAPTER ON PCIE2 4-PORT ADAPTER(10GBE SFP+) DROPS PACKETS |
| IV76204 | ISCSI TOE SENDING IO TO WRONG TARGET |
| IV76214 | VIO Change Mgmt daemon can core dump |
| IV76216 | LUN discovery may fail during cfgmgr |
| IV76243 | ETHERCHANNEL WITH CT3 ADAPTER MAY HANG |
| IV76254 | Unable to start pool after a failed FG operation |
| IV76256 | Unlock adapter is not required when lock did not happen earlier |
| IV76359 | Do not remove adapter if suspend info is not updated |
| IV76508 | EFSENABLE -D WRT LDAP OPERATION FAILS IN SOME SCENARIOS |
| IV76512 | Packets with old MAC are received after changing MAC |
| IV76529 | System crash while running hxecom with modified ent attributes |
| IV76530 | VMLibrary size may be listed as zero |
| IV76538 | SCTP heartbeats are not getting sent within RTO of the path |
| IV76591 | 0514-061 CANNOT FIND A CHILD DEVICE ERRORS ON FC ADAPTERS |
| IV76723 | CAA UNICAST CLU: DMS ON LAST NODE DUE TO INCORRECT DPCOM STATE |
| IV76806 | LSGROUP INCORRECTLY CACHES LDAP USER INFORMATION |
| IV76817 | LPM validation or some VIOS function may give ODM lock errors |
| IV76821 | 'devrsrv' command to force clear SCSI-2 reserve on a vSCSI fails |
| IV77175 | CAA: MERGE FAILURE DUE TO STALE JOIN_PENDING FLAG. |
| IV77179 | viosecure command fails during rule failure with file option |
| IV77182 | cluster Restore may fail in 1 node cluster with PowerVC |
| IV77183 | System crash during adapter EEH recovery. |
| IV77471 | Callback with NDD_LS_DOWN when EEH detected |
| IV77472 | lnc2ent kdb command fails due to corrupted command table entry. |
| IV77475 | ADD FOR POWERVC RESERVE_LOCK POLICY USING EMC 5.3.0.6 OR OLDER |
| IV77506 | CACHEFS CRASHES IN CFIND() |
| IV77509 | ABEND IN RESET_DECV |
| IV77510 | SYSTEM CRASH IN REMOVING THE SEA ADAPTER BY RMDEV COMMAND |
| IV77522 | Disks belonging to cluster are shown as free. |
| IV77529 | DISK NORMAL OPEN FAILS WITH EACCES |
| IV77670 | DIAG RETURNED 2E41-103: CHECKSUM VERIFICATION TEST FAILED |
| IV77687 | ALLOW FC ATTRIBUTES TO BE SHOWN AND CHANGEABLE VIA SMIT |
| IV77744 | Removing SEA device causes hang, SEA threads hang |
| IV77964 | CAA: CHREPOS -C INCORRECTLY SAVES NODE_LOCAL VALUE TO REPO DISK |
| IV78144 | cluster -status command does not always show pool status |
| IV78187 | DSI IN ENTCORE_TX_SEND IN MLXENTDD |
| IV78360 | LDAP USER HAS ADMCHG SET AFTER CHANGING OWN PASSWORD |
| IV78412 | FAILURE OF VIOSBR (VIRTUALCFG) DOESN'T REMOVE WORKING FILES |
| IV78416 | SECLDAPCLNTD INVALID CACHE ATTRIBUTE |
| IV78419 | FC5899 IS MISSING SMIT PANEL FOR CHANGING MEDIA SPEED. |
| IV78420 | NPIV adapter becomes unresponsive |
| IV78422 | Repository Disk is shown as free when it is actually in use |
| IV78425 | ROOTCRNJOBCK FAILS TO HANDLE RELATIVE SYMLINKS & SYMLINK CHAINS |
| IV78444 | LOOPMOUNT COMMAND MAY FAIL FOR READ-ONLY NFS MOUNT |
| IV78453 | IMPROVED DRIVER'S FAIRNESS ALGORITHM TO AVOID I/O STARVATION |
| IV78454 | IMPROVED DRIVER'S FAIRNESS LOGIC TO AVOID I/O STARVATION |
| IV78502 | LOOPING IN EFC_FREE_LOGIN_TBLE |
| IV78549 | CRASH DUE TO BRKPOINT IN GXIB_RAS_REGISTER CALL DURING BOOT |
| IV78576 | CRFS -A QUOTA=NO SHOULD HAVE FAILED DUE TO INVALID ATTRIBUTE |
| IV78682 | Disk validation for LPM of NPIV client fails |
| IV78830 | NPIV CLIENT LPAR REBOOT CAN HANG THE VIOS |
| IV78884 | ALT_DISK_COPY MAY FAIL WHEN MOUNTING FILESYSTEMS |
| IV78895 | NPIV Migration failed with Function npiv_phys_spt tried to |
| IV78897 | LU-level validation for LPM fails with IBM i or Linux clients |
| IV78899 | System crash in entcore_link_change_nic_callback() |
| IV78900 | Removing certain virtual devices incorrectly fails. |
| IV79060 | ABEND IN NMENT_FREE_RX |
| IV79066 | CLMIGCHECK GIVES WARNING ON SYSLOG.CONF UPDATE |
| IV79067 | CLMIGCHECK GIVES RESERVE ERROR ON REPOSITORY DISK |
| IV79069 | VALID AIX LEVELS MIGHT BE INCORRECTLY IDENTIFIED AS INVALID. |
| IV79073 | MISSING INFORMATION FROM CLMIGCHECK ERROR MESSAGE |
| IV79074 | CLMIGCHECK FAILS IF NETSVC.CONF CONTAINS COMMENTED HOSTS LINES |
| IV79281 | CLMIGCHECK MIGHT FAIL ON CLUSTERS WITH MORE THAN TWO NODES. |
| IV79303 | IO.TEM CAN CRASH DURING THE PROCESSING OF FAILED ASYNCHRONOUS |
| IV79469 | LU count listed in tier list output is incorrect. |
| IV79471 | Some SSP VTDs missing after restore operation |
| IV79516 | VKE_INFO QUEUE FULL ERROR DETAIL MESSAGE |
| IV79634 | FAILED PATH ON A CLOSED DISK MAY NOT RECOVER AFTER DISK REOPEN |
| IV79658 | LEVEL.OT MIGRATIONS FAIL IF ALL NODES NOT AT THE SAME CAA |
| IV79710 | NIMADM FAILS WHEN MASTER IS BOOTED FROM BOS_HD5 |
| IV79729 | CLASS 3 NAMESERVER QUERY ODM SUPPORT FOR LEGACY FC ADAPTER |
| IV79874 | SEA CONTROL CHANNEL & TRUNK VIRTUAL ADAPTER SHARE PVID CRASH |
| IV79991 | FAST_FAIL MAY NOT WORK WHEN THE IMM_GID_PN ENABLED |
| IV80113 | viosbr overwrites backups with frequency option. |
| IV80127 | NIB ETHERCHANNEL WITH SR-IOV VF PORT PROBLEM |
| IV80151 | SLOW HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS |
| IV80435 | TRUSTCHK -U OUTPUT INVALID ATTRIBUTES FOR HARDLINKS & SYMLINKS |
| IV80569 | MUSENTDD'S RECEIVE PATH HANGS WHEN IT RECEVIES CERTAIN SIZE PKT |
| IV80598 | System crash after cachefs forced unmount |
| IV80689 | LNCENTDD: MULTICAST ADDRS LOST WHEN PROMISCUOUS MODE TURNED OFF |
| IV80732 | ISAKMPD CORE DUMPED IN SPI_PROTO DESTRUCTOR |
| IV80871 | Race in lncentdd/lnc2entdd driver may make adapter unusable. |
| IV81016 | When the catalog path is invalid artex commands coredump. |
| IV81022 | ISAKMPD CORE DUMP AT COPY_REPL |
| IV81023 | NETSTAT & ENTSTAT FOR ETHERCHANNELS WITH SRIOV DO NOT SHOW MAC |
| IV81024 | MKFS -V JFS2 -O LOG=INLINE /DEV/LOOP0 WITH IV79296 INSTALLED |
| IV81223 | HMC reports that VIOS is busy and not responding to queries |
| IV81241 | MELLANOX V2 DRIVER LOGS LINK UP AND LINK DOWN DURING REBOOT |
| IV81297 | VIO CLIENT CRASHES IN DISK DRIVER DURING LPM WITH GPFS AND PR SH |
| IV81352 | VM deploy fails when using NIC adapters |
| IV81454 | DSI IN RRHBA_QUERY_NIC |
| IV81462 | DF AND LSFS MAY LIST THE WRONG FILESYSTEM |
| IV81739 | LPM: MIGMGR(FIND_DEVICES -T VETH) RC=8 ON DESTINATION VIOS |
| IV81756 | VIOS may crash after using SSP image management in IBM Director |
| IV81820 | CM ATTRIBUTE: MISSING MPIOALGORITHM FOR POWERPATH PVS |
| IV81839 | Virtual tape devices do not configure after upgrading VIOS |
| IV81840 | DEVICE IPSEC_V4 MAY COME UP DEFINED AT BOOT |
| IV81854 | Some objects may be missing in list presented to HMC |
| IV81936 | May lose access to one or more NPIV disks |
| IV81937 | Segfault may occur in ioscli vg or lv related commands. |
| IV81967 | UPDATEIOS:REMOVING INSTALLED EFIX FAILS DUE TO GARBAGE CHARACTER |
| IV82022 | LU -RESIZE NOT RECOGNIZED ON CLIENT AND SCF LOCK ERROR |
| IV82080 | SEGMENTATION FAULT IN RULESCFGSET IF MOTD BIGGER THAN 1024 CHARS |
| IV82145 | IPREPORT DOES NOT DISPLAY TCP OPTION 14 (TCPOPT_ALTCKSUM) |
| IV82194 | CRASH DURING VIOENT CALLBACK WHEN USED WITH ETHERCHANNEL |
| IV82195 | SR-IOV TX_TIMEOUT DEFAULTS TO 30 SECONDS |
| IV82197 | LPM-ED CLIENTS TEMPORARILY LOOSE CONNECTIVTY DUE TO RARPS. |
| IV82449 | VIRTUAL ETHERNET ADAPTER DRIVER MAY GOES INTO DEAD STATE. |
| IV82461 | VIOS may rarely crash during LUN-level validation for LPM |
| IV82463 | Adapters using lncentdd driver may log EEH as permanent Error |
| IV82577 | UNMIRRORVG ROOTVG MAY HANG WITH FW-ASSISTED DUMP & HD6 |
| IV82579 | SLOW HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS |
| IV82596 | SYN NOT RECEIVED WHEN VEA CLIENT TURN OFF CHECKSUM OFFLOAD |
| IV82627 | CAA(MULTICAST): A NODE MAY NOT SEE A REBOOTED NODE AS UP |
| IV82728 | SECONDARY GROUP NOT DETERMINED FOR OLDER NETIQ LDAP SERVERS |
| IV82752 | PACKET ADJUSTED MULTIPLE TIMES BY RRHBADD DRIVER |
| IV82795 | VIOS CRASH WHEN CREATING SEA IN LOW MEMORY CONDITION |
| IV82983 | viosbr -restore not restoring other nodes except initiator node |
| IV83078 | VIOS may crash when doing LUN-level validation for LPM |
| IV83079 | trustchk error on /var/adm/cron/log after migration |
| IV83100 | Handle pv backed virtual target devices during suspend operation |
| IV83121 | After viosecure -undo, viosecure -view reports error |
| IV83143 | I/O HANG IN EFC_FREE_LOGIN_TBLE |
| IV83212 | HOSTNAME ISSUES PREVENT NODE FROM JOINING THE CAA CLUSTER |
| IV83291 | NPIV client hang when cancel command fails |
| IV83544 | TRUSTCHK -U FAILS FOR ALLOW_OWNER ALLOW_GROUP ALLOW_ALL |
| IV83615 | ROLLING UPGRADE FROM DBV3 TO V4 FAILS |
| IV83637 | DRW_LOCK_WRITE() BLOCKING READ THREADS CAUSE HANG. |
| IV83875 | SECLDAPCLNTD MAY FAIL TO HANDLE LONG PASSWORD HASH STRINGS |
| IV84242 | VM validation fails if nondisk type LU configured to NPIV client |
| IV84341 | WRONG UDP FILTERS ADDED BY AIXPERT IPSECSHUNPORTS |
| IV84449 | TCBCK -Y ALL IS RUN AT FIRSTBOOT FROM ALTERNATE DISK IN TCB ENV |
| IV84470 | CRASH DUE TO POSSIBLE MEMORY LEAK IN CAA |
| IV84478 | MULTIPLE DUPLICATE PDAT ODM ENTRIES FOR MPIOAPDISK |
| IV84555 | MAC/VLAN ACL status incorrectly displayed when PVID enabled. |
| IV84636 | BOOTPD DOESN'T FIND ROUTE WITH MANY NETWORK INTERFACES IN USE |
| IV84649 | LPM fails when disk's unique_id has special characters |
| IV84661 | Removing interface,when upgrading FW.Move hang state for FC#EN0H |
| IV84677 | CACHE METHOD DOESN'T SET PROD FLAG CORRECTLY. |
| IV84704 | LARGE RECEIVE ON VIOS IS SLOW WHEN VIO CLIENT HAS CHKSUM OFF |
| IV84767 | FAILOVER HAPPENS ON 802.3AD ETHERCHANNEL WHILE REBOOT |
| IV84769 | PANIC IN TSTART VIA SEAHA_PROCESS_DSCV_INIT |
| IV84776 | NODE CRASHED |
| IV84833 | System crash issuing slot reset after returning EEH Suspend busy |
| IV84889 | CAA UNUSABLE NET_ADDR ON REPOSITORY DISK AFTER CHANGE BOOT IP |
| IV84953 | CM daemon runs out of memory and thus restarts. |
| IV84985 | EEH Resume failure can cause restart to set invalid device state |
| IV85080 | Crash due to race condition of between DEAD and Close |
| IV85145 | CONSTANT DISK_ERR4 ERRORS FOR INTERNAL SCSI DISKS IF HEALTH CHEC |
| IV85215 | RDMAcore returns error if suspend is called more than once. |
| IV85255 | ADDING AUDIT CONFIG FULLPATH OPTION |
| IV85311 | Promiscuous or All mcast flags still shown as set after a close |
| IV85393 | system crash running get_adapter with trace level >= 5 |
| IV85395 | alt_disk_mksysb hangs without the absolute path to device |
| IV85423 | MOUNT MAY FAIL REPORTING MEDIA IS NOT FORMATTED |
| IV85460 | ABEND_TRAP FROM CLOCK |
| IV85508 | caa: core dump if netmon.cf entries are defined |
| IV85593 | NFS3 OPEN FAILURE AFTER NFS3 OPEN WITH O_DIRECT AND O_CIO FAILS |
| IV85670 | VARYONVG HANG IN SCSIDISK_CLOSE() DURING BOOT |
| IV85676 | Repos DOWN event on create led to crash |
| IV85884 | EEH Exit after performing Hot/Fundamental reset after FW update |
| IV85886 | AIXPERT PREREQS ARE NOT MAINTAINED AFTER APPLYING RULES |
| IV85888 | caa: clcomd fails to handle local internal bound ip address |
| IV85891 | DSI CRASH IN VIOENT_OUTPUT |
| IV85895 | ECH_CANNOT_FAILOVER ERROR WHEN REBOOTING |
| IV86129 | Fix CVE-2015-7575 in imap,pop3 |
| IV86237 | Possible race condition between ctrc suspend and trace operation |
| IV86408 | VIOS fails with adapter in use message during LPM |
| IV86523 | SYSTEM MAY HANG WHEN UPGRADING OR REMOVING BOS.RTE.SECURITY |
| IV86535 | system crash while using adapter with FC#EN0S and EN0W |
| IV86538 | SYNCLVODM IS SLOW WHEN THERE ARE MANY DISKS CONFIGURED |
| IV86577 | System crash due to stack overflow when errlogging on slih path |
| IV86666 | mkvopt command allows vopt device names with special characters |
| IV86678 | PACKETS ARE SEEN TWICE IN IPTRACE |
| IV86679 | parallel importpv and reboot fails the importpv operation. |
| IV86684 | handle large image file copies |
| IV86792 | Removal of more than one node from a cluster was giving error |
| IV86794 | Rolling Upgrade does not finish |
| IV86861 | ERROR MESSAGE DURING REPLACEPV NOT RELEVANT |
| IV87015 | clmigcheck fails to find any shared disks |
| IV87020 | VM deploy fails with VIOS_VSCSI_HOST err (relative port id=0) |
| IV87053 | IPTRACE -L DOES NOT ROTATE LOGFILE IF LOGSIZE MORE THAN 2GB |
| IV87134 | VIOS crash in target_cdt_add |
| IV87309 | CRASH IN XHCI_OPEN WHEN ACCESSING /DEV/USBHC0 |
| IV87315 | CAA CLCONFD CORE PTH_USCHED._USCHED_DISPATCH_FRONT._CHK_RESTART |
| IV87496 | The validation fails, while migrating the client partitition |
| IV87670 | IMPROVE HANDLING OF UNDETERMINED DISK ERRORS IN MPIO CONFIGURATI |
| IV87701 | Restore fails for the max_transfer size of the hdisks. |
| IV87704 | LPM will not start with a VASI Open error |
| IV87734 | CLUSTER HEARTBEAT SETTINGS SMIT MENU MAY SHOW VALUE AS ZERO |
| IV87738 | cluster backup through viosbr command gives segmentation fault. |
| IV87742 | Do not use FC port if all NPIV ports are in use |
| IV87743 | Displaying cluster status during cluster node out of network |
| IV87775 | IMPROVE HANDLING OF ABORTED COMMANDS |
| IV87913 | SYSTEM CRASH WITH NPIV_VALIDATE_DO_PORT_LOGIN |
| IV87957 | FC5899 ENTSTAT PRINTS 1818495488 FOR BAD PACKET COUNT IN NON-C |
| IV87958 | DURING FCS ADAPTER RECOVERY NODE CAN CRASH. |
| IV87981 | A POTENTIAL SECURITY ISSUE EXISTS |
| IV88287 | INACTIVE LPM MAY FAIL DUE TO MISSING CAPABILITIES |
| IV88351 | Timing related deadlock issue in LPM |
| IV88688 | RECREATEVG -D NEEDS BETTER USAGE DOCUMENTATION. |
| IV88719 | DSI IN SEADD:SEA_VIRT_INPUT_POST_Q |
| IV88727 | RULESCFGSET MAY ADD GARBAGE LINES IN MOTD FILE |
| IV89148 | Potential cluster hang during svCollect. |
| IV90068 | PCM SSP data collection status may not be updated properly |
| IV90482 | bos.esagent fails to update during VIOS 2.2.5.10 SP install |
Was this topic helpful?
Document Information
Modified date:
19 February 2022
UID