Abstract

LIC-DISK-UNPRED CANNOT ADD DS8000 DISK TO EXISTING ASP
END OF ABSTRACT

Error Description

Unable to add new DS8000 disks to an existing ASP. When using  
SST to add disks to an existing ASP, the user is returned to    
the main SST menu without adding the disks to the ASP. No      
error message is displayed. This problem may occur when adding  
DS8000 disks where a Metro-Mirror or Global-Mirror relationship
has been started for the disk since the partition was last      
IPLed. The IBM i partition must be IPLed in order to add the    
new disk units.                                                
A timing condition may occur with DS8000 volumes when a PPRC    
relationship is started for a volume that reported into the IBM
i without a PPRC relationship. The only recovery is to IPL the  
partition so it re-discovers the volumes with the PPRC          
relationship established.                                      

Problem Summary

Please see the ERROR DESCRIPTION section.                      

Problem Conclusion

A PTF will be created to correct this problem. Apply the PTF to
prevent problems adding new DS8000 units to existing ASPs after
starting a Metro-Mirror or Global-Mirror relationship. If the  
DS8000 volumes may be used for DS8000 HyperSwap, it is          
recommended that Metro-Mirror relationships be started before  
presenting the DS8000 volumes to the IBM i partition even with  
this PTF applied. This practice conserves resources used by IBM
i when a transition to a new Metro-Mirror relationship occurs  
while the IBM i is running.                                    

Temporary Fix

Comments

SRCA6000266                                                    
A6000266                                                        
SRCA6000255                                                    
A6000255                                                        

Circumvention


PTFs Available

R720 MF60646 PTF Cover Letter   6127
R730 MF60961 PTF Cover Letter   6085

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 9400DG300
Failing Module.......................... RCHMGR
Reported Release................... R720
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB08","label":"Cognitive Systems"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0;V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]