IBM Support

IBM Virtual I/O Server support for Power Systems

Fix Readme


Abstract

Downloads for Workload Partition Manager for AIX

Content

Package information

PACKAGE: Update Release 2.2.3.60
IOSLEVEL: 2.2.3.60

VIOS level is NIM Master level must be equal to or higher than
Update Release 2.2.3.60 AIX 6100-09-06 or AIX 7100-03-06

In June 2015, VIOS introduces the minipack as a new service stream delivery vehicle as well as a change to the VIOS fix level numbering scheme. The VIOS "fix level" (the 4th number) has changed to a double digit. VIOS 2.2.3.6 is changed to VIOS 2.2.3.60. Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.

General package notes

Review the list of fixes included in Update Release 2.2.3.60.

To take full advantage of all the function available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 2.2.3.60.

Microcode or system firmware downloads for Power Systems

The VIOS Update Release 2.2.3.60 includes the IVM code, but it will not be enabled on HMC-managed systems. Update Release 2.2.3.60, like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS.

Update Release 2.2.3.60 updates your VIOS partition to ioslevel 2.2.3.60. To determine if Update Release 2.2.3.60 is already installed, run the following command from the VIOS command line:

$ ioslevel

If Update Release 2.2.3.60 is installed, the command output is 2.2.3.60.

Known Capabilities and Limitations

Capabilities and limitations for Shared Storage Pool

The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.

Requirements for Shared Storage Pool

 

Limitations for Shared Storage Pool

Software Installation

SSP Configuration
Feature Min Max
Number of VIOS Nodes in Cluster 1 16
Number of Physical Disks in Pool 1 1024
Number of Virtual Disks (LUs) Mappings in Pool 1 8192
Number of Client LPARs per VIOS node 1 200
Capacity of Physical Disks in Pool 10GB 16TB
Storage Capacity of Storage Pool 10GB 512TB
Capacity of a Virtual Disk (LU) in Pool 1GB 4TB
Number of Repository Disks 1 1
Capacity of Repository Disk 512MB 1016GB
 
Network Configuration
Storage Configuration
Shared Storage Pool capabilities and limitations

Installation information

Pre-installation information and instructions

Please ensure that your rootvg contains at least 30GB and that there is at least 4GB free space before you attempt to update to Update Release 2.2.3.60. Run the lsvg rootvg command, and then ensure there is enough free space.

Example:

$ lsvg rootvg 
VOLUME GROUP:       rootvg                   VG IDENTIFIER:  00f6004600004c000000014306a3db3d
VG STATE:           active                   PP SIZE:        64 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      511 (32704 megabytes)
MAX LVs:            256                      FREE PPs:       64 (4096 megabytes)

LVs:                14                       USED PPs:       447 (28608 megabytes)
OPEN LVs:           12                       QUORUM:         2 (Enabled)
TOTAL PVs:          1                        VG DESCRIPTORS: 2
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         1                        AUTO ON:        yes
MAX PPs per VG:     32512                                     
MAX PPs per PV:     1016                     MAX PVs:        32
LTG size (Dynamic): 256 kilobyte(s)          AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
PV RESTRICTION:     none                     INFINITE RETRY: no

Upgrading from VIOS version lower than 2.1.0

If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version 2.1.0 using the Migration DVD. After the VIOS is at version 2.1.0, the Update/Fixpack 2.2.3.1 must be applied to bring the VIOS to the latest Fix Pack VIOS 2.2.3.1 level. The Update Release 2.2.3.60 can then be applied to bring the VIOS to the latest level.

Note that with this Update Release 2.2.3.60, a single boot alternative to this multiple step process is available to NIM users. NIM users can update by creating a single, merged lpp_source that combines the contents of the Migration DVD with the contents of this Update Release 2.2.3.60 along with the Fix Pack 2.2.3.1.

A single, merged lpp_source is not supported for VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:

After the VIOS migration is complete, from 1.X to 2.X, you must set the Processor Folding, described here under "Migration DVD":

Instructions to disable Processor Folding are detailed at the link below.
See the "Migration DVD" section:

Upgrading from VIOS version 2.1.0 and above

VIOS Update Release 2.2.3.60 may be applied to VIOS level between 2.2.3.0 and 2.2.3.5x. When the Single Step update procedure is used the current level of VIOS must be between 2.2.1.1 and 2.2.2.x.

NOTE: In order to update to Update Release 2.2.3.60 from a level between 2.2.1.1 and 2.2.3.1 in a Single Step, you can put the 2.2.3.1 and 2.2.3.60 updates in the same location and do the update using the updateios command.

 

Before installing the VIOS Update Release 2.2.3.60

The update could fail if there is a loaded media repository.

Checking for a loaded media repository

To check for a loaded media repository, and then unload it, follow these steps.

  1. To check for loaded images, run the following command:

    $ lsvopt
    The Media column lists any loaded media.

  2. To unload media images, run the following commands on all Virtual Target Devices that have loaded images.

    $ unloadopt -vtd <file-backed_virtual_optical_device >

  3. To verify that all media are unloaded, run the following command again.

    $ lsvopt
    The command output should show No Media for all VTDs.

Migrate Shared Storage Pool Configuration

The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 2.2.3.60 using rolling updates.

If your current VIOS is running with Shared Storage Pool from 2.2.1.1 or 2.2.1.3, the following information applies:

A cluster that is created and configured on earlier VIOS Version 2.2.1.1 or 2.2.1.3 must be migrated to version 2.2.1.4 or 2.2.1.5 prior to utilizing rolling updates. This allows the user to keep their shared storage pool devices. When VIOS version is equal or greater than 2.2.1.4 and less than 2.2.3.1, the user needs to download 2.2.3.1 and 2.2.3.60 update images into the same directory, then update the VIOS to Update Release 2.2.3.60 using rolling updates.

If your current VIOS is configured with Shared Storage Pool from 2.2.1.4 or later, the following information applies:

The rolling updates enhancement allows the user to apply Update Release 2.2.3.60 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

The VIOS SSP software monitors node status and will automatically upgrade the cluster to make use of the new capabilities when all the nodes in the cluster have been updated, "cluster -status -verbose" reports "ON_LEVEL" .


Installing the Update Release

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.

To verify the VIOS update files, follow these steps:

$ oem_setup_env
Create a link to openssl
# ln -s /usr/bin/openssl /usr/ios/utils/openssl
Verify the link to openssl was created
# ls -alL /usr/bin/openssl /usr/ios/utils/openssl
Both files should display similar owner and size
# exit

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

Note : While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

If your current level is between 2.2.1.1 and 2.2.2.1, you have to put the 2.2.3.1 and 2.2.3.60 updates in the same location to apply updates in Single Step. The Single Step approach fixes an update problem with the builddate on bos.alt_disk_install.boot_images fileset.

If your current level is 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1, you need to run updateios command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.

Run the following command after the step of "$ updateios –accept –install –dev <directory_name >" completes.

$ updateios –accept –dev <directory_name >

Depending on the VIOs level one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.

MISSING REQUISITES:

     Java14.sdk.1.4.2.0                    # Base Level Fileset
     X11.loc.fr_FR.base.lib 4.3.0.0        # Base Level Fileset
     bos.INed 6.1.6.0                      # Base Level Fileset
     bos.loc.pc.Ja_JP 6.1.0.0              # Base Level Fileset
     bos.loc.utf.EN_US 6.1.0.0             # Base Level Fileset
     bos.mls.rte 6.1.x.x                   # Base Level Fileset

Applying updates

WARNING: If the target node to be updated is part of a redundant VIOS pair, ensure that the VIOS partner node is fully operational before beginning to update the target node. NOTE that for VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

The current level of the VIOS must be 2.2.2.1 or later if you use the Share Storage Pool .

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.

    $ clstartstop -stop -n <cluster_name > -m <hostname >

  4. To apply updates from a directory on your local hard disk, follow the steps:
    • Create a directory on the Virtual I/O Server.
      $ mkdir <directory_name >
    • Using ftp, transfer the update file(s) to the directory you created.

    To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:

    • Mount the remote directory onto the Virtual I/O Server:
      $ mount remote_machine_name:directory /mnt

    The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:

    • Place the CD-ROM into the drive assigned to VIOS.
  5. Commit previous updates by running the updateios command

    $ updateios -commit

  6. Verify the updates files that were copied. This step can only be performed if the link to openssl was created.

    $ cp <directory_path >/ck_sum.bff /home/padmin
    $ chmod 755 </home/padmin>/ck_sum.bff
    $ ck_sum.bff <directory_path >
    If there are missing updates or incomplete downloads, an error message is displayed.

  7. Apply the update by running the updateios command

    $ updateios -accept -install -dev <directory_name >

  8. To load all changes, reboot the VIOS as user padmin .

    $ shutdown -restart

    Note: If shutdown –restart command failed, run swrole –PAdmin in order for padmin to set authorization and establish access to the shutdown command properly.

  9. If cluster services were stopped in step 3, restart cluster services.

    $ clstartstop -start -n <cluster_name > -m <hostname >

  10. Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now 2.2.3.60.

    $ ioslevel


Performing the necessary tasks after installation

Checking for an incomplete installation caused by a loaded media repository

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command:
$ lsrep

If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

Running the lsvopt command should show the media images.

Recovering from an incomplete installation caused by a loaded media repository

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

  1. Unload any media images

    $ unloadopt -vtd <file-backed_virtual_optical_device>

  2. Reinstall the ios.cli.rte fileset by running the following commands.

    To escape the restricted shell:
    $ oem_setup_env
    To install the failed fileset:
    # installp –Or –agX ios.cli.rte –d <device/directory >
    To return to the restricted shell:
    # exit

  3. Restart the VIOS.

    $ shutdown –restart

  4. Verify that the Media Repository is operational by running this command:

    $ lsrep

Additional information

NIM backup, install, and update information

Use of NIM to back up, install, and update the VIOS is supported.

For further assistance on the back up and install using NIM, refer to the NIM documentation.

Note : For install, always create the SPOT resource directly from the VIOS mksysb image. Do NOT update the SPOT from an LPP_SOURCE.

Use of NIM to update the VIOS is supported as follows:
Ensure that the NIM Master is at the appropriate level to support the VIOS image. Refer to the above table in the "Package information" section.

On the NIM Master, use the operation updateios to update the VIOS Server.

Sample: "nim –o updateios –a lpp_source=lpp_source1 ... ... ... "

For further assistance, refer to the NIM documentation.

On the NIM Master, use the operation alt_disk_install to update an alternate disk copy of the VIOS Server.

Sample:
"nim –o alt_disk_install –a source=rootvg –a disk=target_disk
–a fix_bundle=(Value) ... ... ...
"

For further assistance, refer to the NIM documentation.

If NIM is not used to update the VIOS, only the updateios or the alt_root_vg command from the padmin shell can be used to update the VIOS.

Installing the latest version of Tivoli TSM

This release of VIOS contains several enhancements. These enhancements are in the area of POWER virtualization. The following list provides the features of each element by product area.

Note: Version 6.1.0, the previous version of Tivoli TSM, is still shipped and installed from the VIOS installation DVD.

Tivoli TSM version 6.2.2

The Tivoli TSM filesets are now being shipped on the VIOS Expansion Pack, with the required GSKit8 libraries.

The following are sample installation instructions for the new Tivoli TSM filesets:

$ updateios -fs tivoli.tsm.client.api.32bit -dev /dev/cd0

NOTE: Any prerequisite filesets will be pulled in from the Expansion DVD, including for TSM the GSKit8.gskcrypt fileset.

  1. Insert the VIOS Expansion DVD into the DVD drive that is assigned to the VIOS partition.
  2. List Contents of the VIOS Expansion DVD.

    $ updateios -list -dev /dev/cd0
    Fileset Name
    GSKit8.gskcrypt32.ppc.rte 8.0.14.7
    GSKit8.gskcrypt64.ppc.rte 8.0.14.7
    GSKit8.gskssl32.ppc.rte 8.0.14.7
    GSKit8.gskssl64.ppc.rte 8.0.14.7
    ..
    tivoli.tsm.client.api.32bit 6.2.2.0 tivoli.tsm.client.api.64bit 6.2.2.0
    ..

  3. Install Tivoli TSM filesets.
  4. If needed, install additional TSM filesets.

    $ updateios -fs tivoli.tsm.client.ba.32bit -dev /dev/cd0

  5. Verify TSM installed by listing software installed.

    $ lssw
    Sample output:
    ..
    tivoli.tsm.client.api.32bit 6.2.2.0 CF TSM Client - Application Programming
    Interface

Fixes included in this release

Cumulative summary of fixes from previous releases (2.2.3.0 to 2.2.3.50)
APAR Description
IV11065 LDAP USERPRINCIPALNAME ATTRIBUTE FORMAT IS TRUNCATED
IV52705 -migrate -auto flags from HMC doesn't work for link agg device
IV52962 CAA MKCLUSTER FAILS IF REPOSITORY DISK IS EMC CLARIION/INVISTA
IV52970 ethchan_config command will exit with 0 even if command failed
IV52991 Incorrect freespace, capacity reported for a recently created VG
IV52995 ETHER_ATON DOES NOT VALIDATE THE INPUT AS EXPECTED
IV53369 ERRPT ETHERCHANNEL RECOVERY MESSAGE MISSING
IV53373 Inventory for media repository files may fail due to long name
IV53376 PROBLEMS SVC LUN LEADS TO LONG FAIL TIMES, POSSIBLE SSP
IV53379 Possible ioctl hang when S/N changes on opened disk.
IV53381 HMC CRASHES OR OUTPUTS "CHILD PROCESS RETURNED ERROR" ON THE
IV53396 topas -G exits without showing any cluster statistics
IV53634 ADD OPTION TO REMOVE HERALD ATTRIBUTE WITH LOGINMSG COMMAND
IV53635 procfiles and proccred shows negative value for uid and gid
IV53636 lsuser ALL option along with usernames doesn't throw error
IV53640 getaddrinfo cannot handle IPv6 scope/zone
IV53654 Diags may pass even if a failure is present.
IV54203 System crash during high load causing negative runq load value
IV54284 NPIV IO request times out in protocol driver.
IV54317 AUDIT START FAILS SETTING ROLE BASED AUDIT CLASSES
IV54354 Diagnostics does not run on 10Gb and 1Gb FCoE SR, LR, Cu adapter
IV54415 Unable to connect to DB after installing SP1
IV54420 CAA: CLCOMD HANGS WHEN CLUSTER SECURITY CONFIGURED
IV54512 AIX crashed during rmdev of fcs# port
IV54616 EEH error after diagnostics is run on 4port 1Gb adapter
IV54775 Cluster creation succeeds with errors
IV54776 LPM validation of client using NPIV will fail when VIOS
IV54880 AUDIT CRASH IN OBJECTCLEAR
IV54836 Update disk ping driver to indicate when node info is stale
IV54918 Network adapter configuration attributes don't update.
IV54989 runque value in topasout -P has to be an average value
IV54996 PAM_AUTH ALLOWS USER LOGIN WITHOUT ASKING PASSWORD IT'S NOT NULL
IV55092 VIO_DAEMON: ERR UNSUPPORTED ADDRESS FAMILY : 0
IV55188 csm.ivm.server fileset missing
IV55263 mkvdev display wrong message if the Disk is not set max_transfer
IV55358 USR PART REMOVAL FAILURE FOR IOS.CLI.RTE
IV55386 SYSTEM MAY HANG WITH THREADS IN SECOW FUNCTION
IV55442 add/remove failure group fails even when successful
IV55488 fix poold recovery after fatal error in node state change
IV55489 rm any older pool disk cache service registration on kext init
IV55490 xtRead correctly handle non-zero level failures
IV55547 no bridge status in entstat for virtual Ethernet
IV55567 POOL DRIVER ISN'T PINNED AND THUS SYSTEM MAY CRASH
IV55569 Crash at dpuPushSpare+000050
IV55603 DSI in sea_output
IV55632 DSI crash in storfwork:sfwdAddDisk
IV55700 SHUTDOWN -FR FAILS TO COMPLETE A REBOOT OF THE SYSTEM
IV55762 Join node post phase failure after the node was rebooted
IV55763 VIOS SSP crash in storage pool data range lock path.
IV55764 clstartstop command fails with execute permissions
IV55805 IOSCLI COMMAND MAY RETURN INVALID RESULT
IV55807 AIXPERT MUST DIFFERENTIATE FAILEDRULES FROM NOTAPPLICABLERULES
IV55808 system hangs when filesystem and log are degraded
IV55880 Potential hotadapter hot swap failure
IV55883 HEA CAN LOG ERRORS IF JUMBO PACKET IS RECEIVED
IV55884 DSI IN VLAN_GET_USER
IV55952 MISLEADING POOL ID REPORTED IN ERRPT ENTRY FOR VIO_ALERT_EVENT
IV55961 lsgroup command caches user information when it should not be
IV55995 INCORRECT DESCRIPTION IN ERRPT DURING SEA FAILOVER
IV56013 ioscli chdev -udid fails with some network adapters
IV56019 OUT-OF-ORDER FROM SENDER WHEN THERE IS HEAVY BIDIRECTIONAL TRAFF
IV56021 TCP REQUEST/RESPONSE STYLE COMMUNICATION MAY HANG AFTER ACK PKT
IV56023 NETWORK PERFORMANCE DEGRADED WHEN SACK IS ENABLED
IV56058 DEADLOCK BETWEEN ELXENT_ENTER_LIMBO AND ELXENT_OUTPUT
IV56059 SSP commands fail during rolling upgrade
IV56124 OPTION -T OF RC.POWERFAIL DOES NOT WORK
IV56145 rmvdev -sea removes device even if an interface is configured
IV56147 TARGET DROPS TARGET FUNCTIONS: NO FUTURE LOGINS WILL BE ALLOWED
IV56149 concurrent LPMs operation fail with EIO error
IV56213 CVE-2013-5211:THE MONLIST FEATURE IN NTPD ALLOWS REMOTE ATTACKS
IV56389 xmtopasagg dies while topasrec/topas -C running.
IV56392 DSI CRASH IN SCSIDISKPIN:POFCMDPROC.
IV56457 aixpert undo fails to restore suid bits
IV56464 SYSTEM DUMP TO SECONDARY DUMP DEVICE CAN FAIL.
IV56582 CRASH IN ROCE UNDER SEA DURING REBOOT
IV56721 PADMIN CAN'T RUN COMMANDS AFTER TOPASREC STOP AND VIOS UPGRADE
IV56784 LSGCL COMMAND DOESN'T DISPLAY VIRTUAL OPTICAL LIBRARY COMMANDS
IV56801 REDUCEVG: THE DEFAULT STORAGE POOL "ROOTVG" CAN NOT BE REMOVED
IV56892 CRASH IN HD_BEGIN WITH SYNCVG -F -P OF STRIPED LV
IV57304 Fix system crash risk on rmdev of PCIe3 SAS adapter.
IV57307 caa does not prevent adding an existing node to the cluster
IV57347 LSPV -CLUSTERNAME -CAPABLE NOT RELIABLE
IV57411 SYSTEM HANG IN PGSIGNAL
IV57458 MIG_VSCI CORE DUMPING WHEN UDID HAS % CHARACTER
IV57459 Potential security issue.
IV58093 AIXPERT RULE "HLS_DISRMTDMNS" MAY FAIL WHEN TCB IS ENABLED
IV58095 Disk VPD is missing the serial number
IV58096 SYSTEM CRASH IN IMARK
IV58466 ifconfig enX fails on 1Gports when speed is set to 1GFullDuplex
IV58470 NETWORK PERFORMANCE DEGRADATION ON FC5899 ADAPTER
IV58475 Incorrect return code from Paging devices configuration.
IV58477 Add node failure to the SSP cluster after Remove/Replace PV op
IV58481 SSP Import PV operation fails due to stale entry in the DB
IV58489 Blowfish LPA allows login with partial repeated string
IV58765 EEH ERROR CAUSES KERNEL PANIC IN NDD_USRREQ().
IV58766 Potential security issue.
IV58770 CAA: "DEADMAN TIMER TRIGGERED" WITH SANCOMM AND SHUTDOWN OF NODE
IV58830 Ack of PPRC event fails with EINVAL unexpectedly
IV58833 Inactive VRM pages are not getting restored
IV58834 Failure of pool I/O operation
IV59043 UNICAST MODE TCPSOCK CONNECTIONS BOUNCING UP/DOWN
IV59100 JFS2 FS MARKED CORRUPT WHEN USING FIND COMMAND NEEDING FSCK RUN
IV59112 rmdisk failure when clone of clone has snapshot
IV59113 rmdisk hangs when file with clone is being modified
IV59114 Console errors after removing snapshot after rmdisk
IV59115 Conole log entries after removing snapshot after rmdisk
IV59116 DSI fileMigrateLogicalExtent during rmdisk
IV59158 SSP 'pv -replace' failure may prevent future 'pv -replace'
IV59209 LOSS OF REPOS AND REBOOT IN UNICAST CLUSTER CAUSES DMS TIMEOUT
IV59495 SEA creation fails with xml error
IV59529 Certain VIOS commands may hang when run through DRM
IV59735 resume of suspended LPAR may fail
IV59934 Failure to do Secure LPM Migration with Tunnels
IV59968 USYSIDENT DIDN'T REPORT THE CORRECT DISK STATUS
IV60009 Crash with Illegal Trap Intruction Interrupt on entcore
IV60010 Resume of client will fail when the reserve is set to PR_SHARED
IV60012 PRIMARY SEA FAILS TO SEND RARP UPDATES IN CERTAIN CASES
IV60199 LPM while using SSP occasionally fails
IV60297 largesend turned on errorneously when ipsec encapsulation is on
IV60299 Potential security issue.
IV60300 Secure LPM may not create tunnels and may cause LPM to abort
IV60363 EEH permanent error seen on new P8 HW
IV60384 Data inconsistency detected in SSP
IV60499 VIOS hang during host side port bounce
IV60853 SSP cluster hangs when concurrent listings are generated
IV60904 FCA_ERR6 THAT DECODES TO NO FREE CMD MIGHT HANG SOME PROCESSES
IV60982 perfprovider might cause performance impact on VIOS nodes of
IV61136 Migrate interface to first device in link agg when removing
IV62608 part command core dumps in topas_nmon in find_sea_child()
IV62910 NEW USER BY VIOS MKUSER COMMAND GETS HARD-CODED USER ATTRIBUTES
IV62940 UPDATE TIMEZONE RULE FILES TO THE LATEST AVAILABLE
IV63056 NIMADM WITH NIMSH AND NIM CACHE VG FAILS AT NIMADM PHASE 8
IV63294 Physical link up/down errors on ent interfaces
IV63913 CHVG -G CAN FAIL IF FACTOR CHANGE IS REQUIRED
IV63923 AIXPERT -C CAN KILL INETD AND TFTPD
IV64034 ETHERCHANNEL TOTAL FAILURE IN 802.3AD MODE WITH BACKUP ADAPTER.
IV64049 VIOS SHOULD NOT BE FORCED TO REBOOT AFTER MIRRORIOS
IV64087 LVM COMMANDS MAY FAIL ON SVG WITH UNACCOUNTABLE INTERNAL ERROR
IV64555 USER COMMANDS NOT USING INDEX FILES, SUCH AS /ETC/PASSWD.NM.IDX
IV64645 Report error if network POC is missing for too long
IV64650 GETCONF WITH XBS5_ OR POSIX_V6_ ARGUMENTS MIGHT RETURN UNDEFINED
IV64845 IOSCLI CORE DUMP WHILE "LDC -QUERY -DEV ALL"
IV64929 procstack hangs in exit() after it receives sigsegv
IV64934 smitty mkuser fails for security group user
IV65017 NORMAL MODE OPEN FAILS AFTER DIAGNOSTIC OPEN/CLOSE ON DISK
IV65023 COMMAND USERADD DOESN'T SET PRIMARY GROUP PGRP PROPERLY
IV65100 CAA RESTORING CLUSTER FROM CACHE TO 3rd PARTY DISK FAILS
IV65200 trcrpt -s -r is not reporting any data
IV65268 SEA loop detected didn't update trunk adapter state correctly.
IV65286 ENTSTAT/NMON DEGRADES OPEN ADAPTERS RESPONSE TIMES.
IV65296 replacing repository disk fails under the 3rd party disk.
IV65429 caa: include outgoing packets in monitoring ec/sea/vlan traffic
IV65473 CORE DUMP WITH MALLOCOPTIONS POOL_BALANCED
IV65474 VMM CRASH IN V_PFEND DURING PAGEIN
IV65539 ECH_CHAN_RCVRY/ECH_MAIN_CHAN_FAIL ERRPT ENTRIES WHILE REBOOT.
IV65559 CHVG -G VG MAY CAUSE 0516-072 BAD-BLOCK IF DISK BLOCK SIZE IS 4K
IV65569 NIM RESTVG FAILS WHEN NO VG_DATA RESOURCE IS ALLOCATED
IV65761 APPLICATION CRASHES IN MALLOC POOL
IV65788 VIOS CRASHED IN EMUL_SCHEDULE
IV65854 Redundant ADAPTER_DOWN events generated on en1 up/down
IV65855 Set runq and home-srad when restarting bound threads
IV66046 DIAG SERVICE EVENT FAILED - CANNOT REPORT H/W PROBLEM TO SFP
IV66054 varyoffvg w/ passive nodes online in cluster leaves varyon state
IV66058 CLMGR REPLACE REPO <HD> FAILS FOR FIRST RUN FOR 3RD PARTY DISKS
IV66060 MKVDEV LOGS RAS ERROR WITH HYPHENATED FBO BACKING DEVICE
IV66115 SIMULTANEOUS CALLS ON RRHBA_HW_UNINITIALIZE CRASH SYSTEM.
IV66176 INVALID OUTPUT OF VIOSECURE FIREWALL WHEN ICMP RULES SET
IV66273 Start nodes fails as node list shows all nodes status DOWN
IV66298 CRASH IN PAGERUNBIND WHILE FORCE UNMOUNTING A DEGRADED FS
IV66304 ISAKMPD, TMD, IKED, AND IKEV2D ALWAYS SHOW SYSLOG INFORMATION
IV66411 ETHERCHANNEL RECOVERY FAILS WHEN THE PRIMARY ADAPTER LINK IS UP.
IV66429 TWO PROCESSES ACCESSING FILE IN /PROC CAN BOTH HANG.
IV66430 Remote Restart of Client fails
IV66432 COMMAND USERADD DOESN'T SET FILE PERMISSIONS AND DATE PROPERLY
IV66501 Spurious Transmit errors in AIX error log
IV66527 FTP NOT WORKING WITH KRB5LDAP AUTHENTICATION WITH LDAP REGISTRY
IV66577 Cluster create failing with certain names.
IV66727 Network floods when large send is enabled. It rarely happens.
IV66733 Hyperwap quiesce operation times out
IV66777 LSUSER COMMAND DUMPS CORE WHEN "LSUSER ALL" IS CALLED
IV66807 TOPASOUT -A DUMPS CORE AT CHECK_EXISTING
IV66869 inadvertant disabling of p_block_support on P8
IV67090 VIOSBR -RESTORE FAILED WITH EMC DISK AND POWERPATH
IV67097 SECLDAPCLNTD CORE DUMP WHEN STARTING UP
IV67115 CRASH IN J2_UNMAP+0002E8
IV67125 Unable to connect to Database after vios restart
IV67126 VIOS can crash during LPM startup under very rear condition.
IV67200 Hostname change may cause requests to fail with retry required.
IV67457 CRON MAY CALCULATE WRONG LEAP YEAR
IV67463 ENABLING 'TCP_FASTLO' OPTION COULD LEAD TO MEMORY LEAK
IV67464 NON PROMPTED INSTALL NEEDS SPECIFIC OPTION SET FOR SECURE BY DEF
IV67465 VIOS HANGS IF UNABLE TO START VASI OPERATION FOR A STREAM
IV67469 IO failed to resume after fw livedump
IV67470 Crash in FC driver.
IV67473 Sleeping driver thread causing system hang during configuration.
IV67479 DSI IN NBC_LOCATE
IV67507 chsp hangs when pool is 100%
IV67510 SYSTEM CRASH IN DBALLOCAG DUE TO ENOSPC
IV67512 libvio dumps core in vioConnectDB()
IV67549 Unregister 3rd party disks on STOP_NODE
IV67551 Hang during rmdisk operation for SFStore
IV67553 System crash during io to offline disk.
IV67666 CRASH WHEN JFS2 WITH NO LOG BECOMES DIRTY AND GETS FORCE-UNMOUNT
IV67675 Potential event loss when chaging event log size
IV67677 Fail to manage system from console after removal of sfwcomm0
IV67729 BIND ONLY USES THE FIRST SIX DOMAINS IN SEARCH LIST
IV67749 SVMON -D CRASH ON QUERY OF MMAP SEGMENTS
IV67868 During cluster restore, some SSP VTDs are not restored
IV67869 Restoring of the hdiskpowerX devices throws error messages.
IV67870 Unresolved physical location codes for SAS devices
IV67879 cluster commands hang and pool start prevented
IV67880 pool taken offline on all cluster nodes
IV67881 Concurrency error logged after Management Console operations
IV67907 LQUERYLV SECURITY VULNERABILITY (CVE-2014-8904)
IV67915 pool MFS manager deadlock with csCommit
IV67916 SSP cluster nodes unable to start pool after network outage
IV67995 ABEND IN COMPUTE_CRC32 DURING MUSTANG ADAPTER MICROCODE UPDATE
IV68001 SETTING RECEIVE_Q_ELEM HIGH ON CT3 REDRIVER MAKES IFCONFIG HANG
IV68242 memory leak and null pointer issues raised
IV68244 RMSOCK COMPLAINS WITH "GETPROCDATA: MALLOC FAILED"
IV68245 CRASH AFTER DETACHING AN INTERFACE USING ELXENTDD
IV68363 queue_depth for disk/sas/scsd not adjustable to valid values
IV68367 System crashes when missing disks are brought back online.
IV68368 Free space is not reclaimed after removal of thick file.
IV68402 SYSTEM CRASH IN BAD_VNODE_BAD_CALLER IN AHAFS
IV68428 NTP3/NTP4 SECURITY CVE-2014-9293 2014-9294 2014-9295 2014-9296
IV68470 clmigcheck failed to find possible repository disk
IV68651 DIAG -CS RETURNED 2E43-403: CHECKSUM VERIFICATION TEST FAILED
IV68675 MEMORY LEAK IN LIBPERFSTAT API perfstat_config()
IV68714 multibos may fail
IV68751 SEA CRASHES IN INSERT_LSO_IPV4
IV68874 NPIV LPM validation changes to filter client and VIOS wwpns.
IV68904 TOPAS SHOWS DISK BUSY % ABOVE 100
IV68930 READING FROM LOOPBACK CAUSES SYSTEM CRASH LOOP_RW_STRAT+0002B0
IV68939 CRASH AT XTSERVERUPDATEFRAGMENTEDBLOCK
IV68992 CVE-2014-8769
IV68994 A potential security issue exists
IV69039 SCTP HEARTBEATS NOT SENT TO PRIMARY PATH AND NO ASSOCIATION FAIL
IV69040 REALLOC() MAY CORRUPT MALLOC META DATA IF DATA ULIMIT IS REACHED
IV69111 DURING UPDATE OPERATION EMGR FAILS TO REBUILD BOOT IMAGE
IV69114 EN0S/EN0T/ENORRECT ADAPTER FIRMWARE IMAGE DOWNLOAD TO
IV69226 DOMAINLESS=TRUE MAY CAUSE LDAP USER TO BELONG TO 'SYSTEM' GROUP
IV69311 MPIO Path recovers too soon when a LUN is unmapped
IV69332 Shared storage pool stale partitions not getting synced.
IV69334 ioslevel changes for AIX 6.1.9.45 release.
IV69335 SSP crash when fragmented block deleted during rebuild.
IV69394 Fix rolling upgrade.
IV69450 FSCK does not report corruption to a specific superblock field
IV69485 ARTEXDIFF SLOW WITH LARGE NUMBER OF USERS AFTER IV47382
IV69499 VIOS CHTCPIP COMMAND TO CHANGE GATEWAY IP ADDRESS FAILS
IV69527 Heavy transmit data on FC5899/FC1763 results in machine hang
IV69530 Adapter does not recover from EEH.
IV69578 System is unresponsive for commands (fcstat)
IV69632 EEH errors logged in errpt while system reboot/bringup
IV69720 Duplicate addition of Node that is DOWN
IV69787 PCIE2 2-PORT 10GBE SR ADAPTER DOES NOT RESET LINK
IV69792 Possible disk I/O hang on adapter firmware issue.
IV69808 A potential security issue exists
IV69868 STACK-OVERFLOW WHEN IPSEC IS ENABLED ON IPV6-CONFIGURED SYSTEM
IV70378 GETSERVBYNAME SUBROUTINE DOESN'T RETURN PROTOCOL FOR LDAP SERVIC
IV70381 Shared storage pool fragmented block corruption.
IV70392 DAP BASED USER MAY FAIL TO LOGIN WITH SPECIAL CHAR IN PASSWORD
IV70422 CAA NO DMS FOR ISOLATED NODE IF NON-CAA INTERFACES ARE UP
IV70454 SYSTEM CRASH FROM BAD LOCK ADDRESS PASSED BY NPIV_UNBLOCK_LOGIN
IV70497 MAY CRASH IN EAMAPOUT WITH MODS ENABLED
IV70654 SSP LU creation may fail intermittently.
IV70802 VIOS SSP commands cannot connect to DB
IV71032 ioscli lspath command gives a 0 return code on some failures
IV71036 Loss of repos disk access causes many disk errors
IV71159 vio_daemon is repeatedly respawning
IV71160 Error trying to map/access an SSP LU
IV71308 dumpcheck calculates incorrect dump device size for 4k disks
IV71314 ETHERCHANNEL W/SHORT INTERVAL CAUSES SWITCH TO DISABLE PORTS
IV71322 Make unique_id string W3C XML compliant
IV71339 NPIV starves VSCSI while there are available processors
IV71482 NIMADM OPERATION RESOLVES NIM CLIENT RESOURCE NAME INCORRECTLY
IV71570 handle the case of missing pv in change management.
IV71581 ADDRESS UNREACHABLE NOTIFICATION NOT DELIVERED TO THE USER
IV71849 PUTUSERATTR MEMORY LEAK
IV72056 Fails to resume partition with SSP LUs mapped.
IV72188 I/O failure due to SCSI reservation conflict
IV73126 Trace modification increases /var usage

Summary of fixes in current release (2.2.3.60)

APAR Description
IV59092 PMPERFREC SERVICE NOT STARTED ON INSTALL
IV61219 LVM MAY NOT DO CORRECT BAD BLOCK RELOCATION
IV63206 VIOS: viosbr command is failing with error.
IV64843 SYSTEM CRASH IN FP_FSTAT DOING IOCTL TO LOOPMOUNT DEVICE
IV65020 Incorrect array index when accessing number of paths.
IV65564 Missing valid queue depth range for disk/sas/scsd
IV65783 IPv6 largesend over virtual Ethernet
IV65906 Correct ipsec failure to enable proper LPM.
IV66113 Restricting root user to have only local groups for admgroups
IV66280 USB 3.0 adapter is stuck and no devices are seen
IV67052 AMS DATA VALIDATION FAILS
IV67228 SYSTEM CRASH DUE TO RECURSIVE LOCK IN FC5287 DRIVER
IV67462 IPSEC COMMUNICATION FAILS DUE TO INCONSISTENT SAS WHEN RE-KEYING
IV67571 Excessive Interrupt Disablement mitigation
IV68261 joinvg with -f option may not remove missing disk from VG
IV68262 extendvg dumps core during cleanup
IV68264 FC1763 and FC5899 may hog CPU in recovery paths
IV68272 COMPRESS PM OUTPUT FILES
IV68835 Receive section may not start working on FC1763 & FC5899
IV68902 FC1763/FC5899 does not increment adapter reset count in entstat
IV69104 MALLOCTYPE=3.1_64BIT CAN CAUSE CORE DUMP.
IV69355 SEA LARGESEND CAN CAUSE TCP BAD HEADER OFFSET ON VIRTUAL CLIENT
IV69489 NDD_ENABLE_ADDRESS adds address multiple times on FC1763/FC5899
IV69531 FC1763/FC5899 IOCTL and KPROC serialization
IV69897 AIX /USR/SYSV/BIN/DF COMMAND REPORTS INCORRECT VALUES
IV69902 LNCENTDD UNUSED PORTS LOGS LNCENT_PLINK_DOWN
IV70173 LOCAL USER LOGIN FAILS WITH LDAP ERROR MESSAGE
IV70553 SAS CD DRIVE MAPPINGS CHANGED WHEN VIOS REBOOTED
IV70843 AIXPERT MAY ADD WRITE PERMISSION TO PROGRAMS
IV71649 CAA: MKCLUSTER FAILS TO CREATE /ETC/CLUSTER/LOCKS DIRECTORY
IV71787 LSCLUSTER DOES NOT RECOGNIZE AN EXISTING NODE NAME
IV71806 PART FAILS TO CREATE TAR FILE AFTER SETTING HIGH SECURITY LEVEL
IV72007 INCORRECT READ MAY OCCUR DURING JOINVG
IV72025 Assert in emfsc_free_cmd_elem
IV72063 Unable to start node after chrepos
IV72066 CLUSTER0 MISSING LEADS TO MKCLUSTER FAILURE
IV72122 NO ERRORS SEEN WHEN DUPLICATE FLAGS IN "NO" COMMAND ARE USED
IV72133 caa: no gossip transmission on boot can lead to split-brain
IV72147 CFGIPSEC NOT PROPERLY HANDLING COMMENTS IN NEXTBOOT FILE
IV72379 SYSTEM MAY CRASH DURING I/O TO STRIPED LV WITH INFINITE RETRY
IV72499 CORE DUMP AFTER FAILED DLOPEN IN 64-BIT PROGRAM
IV72562 SFW SFWCOM APPEARS UP TO CAA WHEN IT IS NOT FUNCTIONAL
IV72705 FSCK HANGS WHILE REPAIRING ACL INODE
IV72781 IPSECSTAT DISPLAYING NEGATIVE VALUES
IV72893 CLCOMD CAN USE TOO MUCH CPU WHEN AHAFS NOT ACCESSIBLE
IV72905 Fixing the static code analyser issues for elxentdd driver
IV73000 INCORRECT DETAIL IN VIOD_ALERT_EVENT IF CM DB FS CANNOT BE CHECK
IV73156 LVM ops on mirror pool LVs in VGs with many disks can be slow
IV73202 mklv on 4K block disk dumps core
IV73203 EN0S/T,EN0U/V,EN0W/XILSIN NIM DIAG MODE FOR
IV73257 Clients do not see SSP LUs after VIOS reboots
IV73259 SUPPORT FOR CRITICAL VG ATTRIBUTE ALT_DISK_COPY/ALT_DISK_INSTALL
IV73437 rmcluster failure in large clusters
IV73440 SYSTEM CRASH IN DOUBLE FREE SCSIDISK_CONFIG
IV73516 CRASH DOUBLE FREE IN SCSIDISK_TERM_MPIO
IV73528 ARTEXGET IS SLOW WITH LARGE NUMBER OF COMMANDS TO EXECUTE
IV73529 Possible crash at boot time in pkcs11
IV73567 SSP cluster creation failed on VLAN device
IV73572 topas -C shows incorrect data for APP, PSz
IV73573 Cluster services may not start after reboot of remote site node
IV73642 LSDEV -TYPE ENT4SEA EXCLUDES ROCE ADAPTER
IV73758 EXECUTING STOPSRC -G IKE CAN HANG TMD
IV73768 EXTENDVG OF CONC VG MAY FORCE THE VG OFFLINE ON REMOTE NODE
IV73769 system crash in hd_reduce(), lvm layer
IV73770 joinvg in concurrent VG may put disks in missing
IV73838 caa: inactive node fails to generate remote node_up ahafs event
IV73951 I/O may hung during SCSI ACA Error Condition.
IV73976 A potential security issue exists CVE-2014-3566
IV74100 varyon/varyoff of conc VG doesn't keep remote timestamp in sync
IV74104 chvg -l will not disable multi-node-varyon-protection
IV74178 LUN discovery may fail during cfgmgr on NPIV Client.
IV74329 CVE-2015-0261 and CVE-2015-2154 tcpdump vulnerablity fix
IV74423 Adapter goes unresponsive and rmdev also hangs
IV74424 INFINIBAND HANG IN ICMCLOSE USING IBSTAT
IV74425 VIO Adapter statistics displays misaligned Virtual Memory Info.
IV74484 ENTSTAT ON SEA FAILS WITH ENTSTAT_MODE ENVIRONEMT VARIABLE
IV74508 Remove dkstat structure for loopdd (loopback) if CFG_INIT fails
IV74540 CRON AND AT JOBS NOT WORKING FOR DOMAINLESS USERS
IV74606 ALT_DISK_COPY ON 4K DISK TRIGGERS LVM_IO_FAIL
IV74650 caa: repository disk replacement may fail
IV74780 caa: high cpu utilization in aha_rcv process
IV74837 System crashes after usb drive reconnect, and umount of FS
IV74927 A potential security issue exists CVE-2015-2808
IV74946 clconfd lvm conflict with chrepos
IV74990 POOLADM PPSECTOR COMMAND CAN HANG THE POOL
IV74992 SSP POOL MAY DO EXCESSIVE ERROR RECOVERY
IV75001 MIGRATEPV FAILURE MAY CAUSE IO HANG IN CONCURRENT VG
IV75041 MEMORY LEAKS RELATE TO GET_NIS_ENTRY ROUTINE
IV75053 Point to Point connection establishment may fail
IV75251 SolidDB has wrapped memory growth due to unclosed connections
IV75253 FG create failed after replacing PVs
IV75273 LSLDAP KEEPS ON FAILLING WHEN LDAP SERVER CLOSES CONNECTION
IV75364 CAA: UNEXPECTED START_NODE BY PEER NODE LEADS TO AST PANIC
IV75385 Improved driver's fairness logic to avoid I/O starvation
IV75387 CAA: SYSTEM WILL CRASH IF GOSSIP PACKET HAS ID = 0
IV75388 updateios gives incorrect error codes/messages for some options
IV75490 set fsize to unlimited while creating new user on VIOS
IV75495 CODEGCHECK MIGHT FAIL WITH FALSE ERROR, DISPLAYING SCRIPTED
IV75534 New mirror copies not balanced in replica set.
IV75538 caa: defined pv that matches repo pvid causes mkcluster to fail
IV75589 SYSTEM CRASHES IN ICMCLOSEQP1
IV75590 Support of UDP RSS hash for FC5899
IV75620 solid DB has many sockets to perfprovider in CLOSE_WAIT state
IV75625 System loses network connection about 15 minutes after restart.
IV75738 LSSEC PERFORMANCE SUFFERS WHEN EFS IS ENABLED
IV75761 Cluster fails to commit.
IV75891 clmigcheck should automatically assign disk PVIDs
IV75892 An invalid /etc/cluster/rhosts file might not be detected.
IV76050 THE UUID_CREATE SUBROUTINE MAY CREATE DUPLICATE UUIDS
IV76129 xmtopas might restart on any start of any of its consumers
IV76130 Invalid repository reserve policy not detected on remote nodes
IV76151 IKED LOOPS AND CAUSES CPU LOAD WHEN 0-BYTE DATAGRAM IS PRESENT
IV76214 VIO Change Mgmt daemon can core dump
IV76215 LUN discovery may fail during cfgmgr
IV76216 LUN discovery may fail during cfgmgr
IV76218 System crash in pkcs11:P11_SESS_acquire_obj()
IV76219 caa: reduce the number of lock tries in stop/start
IV76252 PASSWORD AGING DOESN'T WORK FOR LDAP IF LDAP USES LOCAL DEFAULTS
IV76257 Incorrect SRN 2E17-203 displayed for VPD failure
IV76260 PERFSTAT KERNEXT DOES DSI IN PTX_LOAD_IFNET_HELPER64
IV76503 POSIX_SPAWN FUNCTIONS MAY CORE DUMP IN 64-BIT PROGRAM
IV76508 EFSENABLE -D WRT LDAP OPERATION FAILS IN SOME SCENARIOS
IV76531 LPM fails with PCIDMA errors in errpt on target/destination
IV76532 Potential core dump in MPIO command library
IV76533 Possible I/O error during a Hyperswap failover
IV76537 Missing last path failure reason for PG SN mismatch
IV76723 CAA UNICAST CLU: DMS ON LAST NODE DUE TO INCORRECT DPCOM STATE
IV76806 LSGROUP INCORRECTLY CACHES LDAP USER INFORMATION
IV76820 I/O stress on large number of LUNs may cause poor performance
IV76821 'devrsrv' command to force clear SCSI-2 reserve on a vSCSI fails
IV76975 panic_trap in entcore_tx_enqueue() function.
IV77166 Number SAS RAID hdisks in order of drive slots
IV77175 CAA: MERGE FAILURE DUE TO STALE JOIN_PENDING FLAG.
IV77177 Address failures/limitations with viosdevattr profile.
IV77182 cluster Restore may fail in 1 node cluster with PowerVC
IV77475 ADD FOR POWERVC RESERVE_LOCK POLICY USING EMC 5.3.0.6 OR OLDER
IV77520 NETWORK ADAPTERS PHYSICAL LOCATION MAY NOT BE SHOWN
IV77525 scsidisk_close fails to clear the PR reservation
IV77529 DISK NORMAL OPEN FAILS WITH EACCES
IV77530 devrsrv opening the disk with SC_SINGLE affect disk open
IV77531 SFW_OPENING state might be set for a disk after open failures
IV77616 Bell3 adapter failing on aixerr and STX
IV77885 IVM serviciability features broken without Java5
IV77928 For PCIe2 4-Port 8Gb FC Adapter attributes smitty does not work
IV77932 Crypto device driver crashes y4_eeh_read_slot+000368
IV78112 mklvcopy allows upperbound greater than VG's upperbound
IV78115 Running diags leaves an FC Adapter port in DIAGNOSE state.
IV78116 FC1763 & FC5899 may successfully pass corrupted TCPIP packets
IV78117 vSCSI adapter stops responding
IV78294 USB Mouse does not work on P8 system
IV78453 IMPROVED DRIVER'S FAIRNESS ALGORITHM TO AVOID I/O STARVATION
IV78454 IMPROVED DRIVER'S FAIRNESS LOGIC TO AVOID I/O STARVATION
IV78470 I/O could fail during LPM in certain conditions
IV78681 Client lpar with NPIV virtual driver hangs after migration
IV78691 LPM between P8 to P8 fails using particular compatibilty mode

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPHKW","label":"PowerVM Virtual I\/O Server"},"Component":"","Platform":[{"code":"PF002","label":"AIX"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date:
19 February 2022

UID

hpc1vios74d3fe35