This Readme contains installation and other information about VIOS Update Release 2.2.3.60
Package information
PACKAGE: Update Release 2.2.3.60
IOSLEVEL: 2.2.3.60
| VIOS level is | NIM Master level must be equal to or higher than |
|---|---|
| Update Release 2.2.3.60 | AIX 6100-09-06 or AIX 7100-03-06 |
In June 2015, VIOS introduces the minipack as a new service stream delivery vehicle as well as a change to the VIOS fix level numbering scheme. The VIOS "fix level" (the 4th number) has changed to a double digit. VIOS 2.2.3.6 is changed to VIOS 2.2.3.60. Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.
General package notes
Review the list of fixes included in Update Release 2.2.3.60.
To take full advantage of all the function available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 2.2.3.60.
Microcode or system firmware downloads for Power Systems
The VIOS Update Release 2.2.3.60 includes the IVM code, but it will not be enabled on HMC-managed systems. Update Release 2.2.3.60, like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS.
Update Release 2.2.3.60 updates your VIOS partition to ioslevel 2.2.3.60. To determine if Update Release 2.2.3.60 is already installed, run the following command from the VIOS command line:
$ ioslevel
If Update Release 2.2.3.60 is installed, the command output is 2.2.3.60.
Known Capabilities and Limitations
Capabilities and limitations for Shared Storage Pool
The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.
Requirements for Shared Storage Pool
- Platforms: POWER6 and later (includes Blades), IBM PureFlex Systems (Power Compute Nodes only)
- System requirements per SSP node:
- Minimum CPU: 1 CPU of guaranteed entitlement
- Minimum memory: 4GB
- Storage requirements per SSP cluster (minimum): 1 fiber-channel attached disk for repository, 1 GB
- At least 1 fiber-channel attached disk for data, 10GB
Limitations for Shared Storage Pool
Software Installation
- All VIOS nodes must be at version 2.2.1.3 or later.
- When installing updates for VIOS Update Release 2.2.3.60 participating in a Shared Storage Pool, the Shared Storage Pool Services must be stopped on the node being upgraded.
| Feature | Min | Max |
|---|---|---|
| Number of VIOS Nodes in Cluster | 1 | 16 |
| Number of Physical Disks in Pool | 1 | 1024 |
| Number of Virtual Disks (LUs) Mappings in Pool | 1 | 8192 |
| Number of Client LPARs per VIOS node | 1 | 200 |
| Capacity of Physical Disks in Pool | 10GB | 16TB |
| Storage Capacity of Storage Pool | 10GB | 512TB |
| Capacity of a Virtual Disk (LU) in Pool | 1GB | 4TB |
| Number of Repository Disks | 1 | 1 |
| Capacity of Repository Disk | 512MB | 1016GB |
- Maximum number of physical volumes that can be added to or replaced from a pool at one time: 64
- The Shared Storage Pool cluster name must be less than 63 characters long.
- The Shared Storage Pool pool name must be less than 127 characters long.
- The supported LU size is 4TB. However, it is recommended to limit the size of individual luns to 16 GB for optimal performance in cases where all of the following conditions are met:
- The server generates a random access pattern for the I/O device.
- There are more than 8 processes concurrently performing I/O.
- The performance of the application is dependent on the I/O subsystem throughput.
Network Configuration
- Uninterrupted network connectivity is required for operation. i.e. The network interface used for Shared Storage Pool configuration must be on a highly reliable network which is not congested.
- A Shared Storage Pool configuration can use IPV4 or IPV6, but not a combination of both.
- A Shared Storage Pool configuration should configure the TCP/IP resolver routine for name resolution to resolve host names locally first, and then use the DNS. For step by step instructions, refer to the TCP/IP name resolution documentation in the IBM Knowledge Center.
- The forward and reverse lookup should resolve to the IP address/hostname that is used for Shared Storage Pool configuration.
- It is recommended that the VIOSs that are part of the Shared Storage Pool configuration keep their clocks synchronized.
Storage Configuration
- Virtual SCSI devices provisioned from the Shared Storage Pool may drive higher CPU utilization than the classic Virtual SCSI devices.
- Using SCSI reservations (SCSI Reserve/Release and SCSI-3 Reserve) for fencing physical disks in the Shared Storage pool is not supported.
- SANCOM will not be supported in a Shared Storage Pool environment.
Shared Storage Pool capabilities and limitations
- On the client LPAR Virtual SCSI disk is the only peripheral device type supported by SSP at this time.
- When creating Virtual SCSI Adapters for VIOS LPARs, the option "Any client partition can connect" is not supported.
- VIOSs configured for SSP require that Shared Ethernet Adapter(s) (SEA) be setup for Threaded mode (the default mode). SEA in Interrupt Mode is not supported within SSP.
- VIOSs configured for SSP can be used as a Paging Space Partition (PSP), but the storage for the PSP paging spaces must come from logical devices not within a Shared Storage Pool. Using a VIOS SSP logical unit (LU) as an Active Memory Sharing (AMS) paging space or as the suspend/resume file is not supported.
Installation information
Pre-installation information and instructions
Please ensure that your rootvg contains at least 30GB and that there is at least 4GB free space before you attempt to update to Update Release 2.2.3.60. Run the lsvg rootvg command, and then ensure there is enough free space.
Example:
$ lsvg rootvg VOLUME GROUP: rootvg VG IDENTIFIER: 00f6004600004c000000014306a3db3d VG STATE: active PP SIZE: 64 megabyte(s) VG PERMISSION: read/write TOTAL PPs: 511 (32704 megabytes) MAX LVs: 256 FREE PPs: 64 (4096 megabytes) LVs: 14 USED PPs: 447 (28608 megabytes) OPEN LVs: 12 QUORUM: 2 (Enabled) TOTAL PVs: 1 VG DESCRIPTORS: 2 STALE PVs: 0 STALE PPs: 0 ACTIVE PVs: 1 AUTO ON: yes MAX PPs per VG: 32512 MAX PPs per PV: 1016 MAX PVs: 32 LTG size (Dynamic): 256 kilobyte(s) AUTO SYNC: no HOT SPARE: no BB POLICY: relocatable PV RESTRICTION: none INFINITE RETRY: no
Upgrading from VIOS version lower than 2.1.0
If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version 2.1.0 using the Migration DVD. After the VIOS is at version 2.1.0, the Update/Fixpack 2.2.3.1 must be applied to bring the VIOS to the latest Fix Pack VIOS 2.2.3.1 level. The Update Release 2.2.3.60 can then be applied to bring the VIOS to the latest level.
Note that with this Update Release 2.2.3.60, a single boot alternative to this multiple step process is available to NIM users. NIM users can update by creating a single, merged lpp_source that combines the contents of the Migration DVD with the contents of this Update Release 2.2.3.60 along with the Fix Pack 2.2.3.1.
A single, merged lpp_source is not supported for VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:
SDD and SDDPCM migration procedures when migrating VIOS from version 1.x to version 2.x
After the VIOS migration is complete, from 1.X to 2.X, you must set the Processor Folding, described here under "Migration DVD":
Instructions to disable Processor Folding are detailed at the link below.
See the "Migration DVD" section:
Virtual I/O Server support for Power Systems
Upgrading from VIOS version 2.1.0 and above
VIOS Update Release 2.2.3.60 may be applied to VIOS level between 2.2.3.0 and 2.2.3.5x. When the Single Step update procedure is used the current level of VIOS must be between 2.2.1.1 and 2.2.2.x.
NOTE: In order to update to Update Release 2.2.3.60 from a level between 2.2.1.1 and 2.2.3.1 in a Single Step, you can put the 2.2.3.1 and 2.2.3.60 updates in the same location and do the update using the updateios command.
Before installing the VIOS Update Release 2.2.3.60
The update could fail if there is a loaded media repository.
Checking for a loaded media repository
To check for a loaded media repository, and then unload it, follow these steps.
- To check for loaded images, run the following command:
$ lsvopt
The Media column lists any loaded media. - To unload media images, run the following commands on all Virtual Target Devices that have loaded images.
$ unloadopt -vtd <file-backed_virtual_optical_device >
- To verify that all media are unloaded, run the following command again.
$ lsvopt
The command output should show No Media for all VTDs.
Migrate Shared Storage Pool Configuration
The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 2.2.3.60 using rolling updates.
If your current VIOS is running with Shared Storage Pool from 2.2.1.1 or 2.2.1.3, the following information applies:
A cluster that is created and configured on earlier VIOS Version 2.2.1.1 or 2.2.1.3 must be migrated to version 2.2.1.4 or 2.2.1.5 prior to utilizing rolling updates. This allows the user to keep their shared storage pool devices. When VIOS version is equal or greater than 2.2.1.4 and less than 2.2.3.1, the user needs to download 2.2.3.1 and 2.2.3.60 update images into the same directory, then update the VIOS to Update Release 2.2.3.60 using rolling updates.
If your current VIOS is configured with Shared Storage Pool from 2.2.1.4 or later, the following information applies:
The rolling updates enhancement allows the user to apply Update Release 2.2.3.60 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.
To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:
- All VIOS logical partitions must have VIOS Update Release version 2.2.1.4 or later installed. After the update, you can verify that the logical partitions have the new level of software installed by typing the cluster -status -verbose command from the VIOS command line. In the Node Upgrade Status field, if the status of the VIOS logical partition is displayed as UP_LEVEL , the software level in the logical partition is higher than the software level in the cluster. If the status is displayed as ON_LEVEL , the software level in the logical partition and the cluster is the same.
- All VIOS logical partitions must be running. If any VIOS logical partition in the cluster is not running, the cluster cannot be upgraded to use the new SSP capabilities.
The VIOS SSP software monitors node status and will automatically upgrade the cluster to make use of the new capabilities when all the nodes in the cluster have been updated, "cluster -status -verbose" reports "ON_LEVEL" .
Installing the Update Release
There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.
To verify the VIOS update files, follow these steps:
$ oem_setup_env
Create a link to openssl
# ln -s /usr/bin/openssl /usr/ios/utils/openssl
Verify the link to openssl was created
# ls -alL /usr/bin/openssl /usr/ios/utils/openssl
Both files should display similar owner and size
# exit
Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.
If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.
Note : While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.
If your current level is between 2.2.1.1 and 2.2.2.1, you have to put the 2.2.3.1 and 2.2.3.60 updates in the same location to apply updates in Single Step. The Single Step approach fixes an update problem with the builddate on bos.alt_disk_install.boot_images fileset.
If your current level is 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1, you need to run updateios command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.
Run the following command after the step of "$ updateios –accept –install –dev <directory_name >" completes.
$ updateios –accept –dev <directory_name >
Depending on the VIOs level one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.
MISSING REQUISITES:
Java14.sdk.1.4.2.0 # Base Level Fileset
X11.loc.fr_FR.base.lib 4.3.0.0 # Base Level Fileset
bos.INed 6.1.6.0 # Base Level Fileset
bos.loc.pc.Ja_JP 6.1.0.0 # Base Level Fileset
bos.loc.utf.EN_US 6.1.0.0 # Base Level Fileset
bos.mls.rte 6.1.x.x # Base Level Fileset
Applying updates
WARNING: If the target node to be updated is part of a redundant VIOS pair, ensure that the VIOS partner node is fully operational before beginning to update the target node. NOTE that for VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.
The current level of the VIOS must be 2.2.2.1 or later if you use the Share Storage Pool .
- Log in to the VIOS as the user padmin.
- If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
- If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.
$ clstartstop -stop -n <cluster_name > -m <hostname >
- To apply updates from a directory on your local hard disk, follow the steps:
- Create a directory on the Virtual I/O Server.
$ mkdir <directory_name > - Using ftp, transfer the update file(s) to the directory you created.
To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:
- Mount the remote directory onto the Virtual I/O Server:
$ mount remote_machine_name:directory /mnt
The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:
- Place the CD-ROM into the drive assigned to VIOS.
- Create a directory on the Virtual I/O Server.
- Commit previous updates by running the updateios command
$ updateios -commit
- Verify the updates files that were copied. This step can only be performed if the link to openssl was created.
$ cp <directory_path >/ck_sum.bff /home/padmin
$ chmod 755 </home/padmin>/ck_sum.bff
$ ck_sum.bff <directory_path >
If there are missing updates or incomplete downloads, an error message is displayed. - Apply the update by running the updateios command
$ updateios -accept -install -dev <directory_name >
- To load all changes, reboot the VIOS as user padmin .
$ shutdown -restart
Note: If shutdown –restart command failed, run swrole –PAdmin in order for padmin to set authorization and establish access to the shutdown command properly.
- If cluster services were stopped in step 3, restart cluster services.
$ clstartstop -start -n <cluster_name > -m <hostname >
- Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now 2.2.3.60.
$ ioslevel
Performing the necessary tasks after installation
Checking for an incomplete installation caused by a loaded media repository
After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.
Check the Media Repository by running this command:
$ lsrep
If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.
Running the lsvopt command should show the media images.
Recovering from an incomplete installation caused by a loaded media repository
To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:
- Unload any media images
$ unloadopt -vtd <file-backed_virtual_optical_device>
- Reinstall the ios.cli.rte fileset by running the following commands.
To escape the restricted shell:
$ oem_setup_env
To install the failed fileset:
# installp –Or –agX ios.cli.rte –d <device/directory >
To return to the restricted shell:
# exit - Restart the VIOS.
$ shutdown –restart
- Verify that the Media Repository is operational by running this command:
$ lsrep
Additional information
NIM backup, install, and update information
Use of NIM to back up, install, and update the VIOS is supported.
For further assistance on the back up and install using NIM, refer to the NIM documentation.
Note : For install, always create the SPOT resource directly from the VIOS mksysb image. Do NOT update the SPOT from an LPP_SOURCE.
Use of NIM to update the VIOS is supported as follows:
Ensure that the NIM Master is at the appropriate level to support the VIOS image. Refer to the above table in the "Package information" section.
On the NIM Master, use the operation updateios to update the VIOS Server.
Sample: "nim –o updateios –a lpp_source=lpp_source1 ... ... ... "
For further assistance, refer to the NIM documentation.
On the NIM Master, use the operation alt_disk_install to update an alternate disk copy of the VIOS Server.
Sample:
"nim –o alt_disk_install –a source=rootvg –a disk=target_disk
–a fix_bundle=(Value) ... ... ... "
For further assistance, refer to the NIM documentation.
If NIM is not used to update the VIOS, only the updateios or the alt_root_vg command from the padmin shell can be used to update the VIOS.
Installing the latest version of Tivoli TSM
This release of VIOS contains several enhancements. These enhancements are in the area of POWER virtualization. The following list provides the features of each element by product area.
Note: Version 6.1.0, the previous version of Tivoli TSM, is still shipped and installed from the VIOS installation DVD.
Tivoli TSM version 6.2.2
The Tivoli TSM filesets are now being shipped on the VIOS Expansion Pack, with the required GSKit8 libraries.
The following are sample installation instructions for the new Tivoli TSM filesets:
$ updateios -fs tivoli.tsm.client.api.32bit -dev /dev/cd0
NOTE: Any prerequisite filesets will be pulled in from the Expansion DVD, including for TSM the GSKit8.gskcrypt fileset.
- Insert the VIOS Expansion DVD into the DVD drive that is assigned to the VIOS partition.
- List Contents of the VIOS Expansion DVD.
$ updateios -list -dev /dev/cd0
Fileset Name
GSKit8.gskcrypt32.ppc.rte 8.0.14.7
GSKit8.gskcrypt64.ppc.rte 8.0.14.7
GSKit8.gskssl32.ppc.rte 8.0.14.7
GSKit8.gskssl64.ppc.rte 8.0.14.7
..
tivoli.tsm.client.api.32bit 6.2.2.0 tivoli.tsm.client.api.64bit 6.2.2.0
.. - Install Tivoli TSM filesets.
- If needed, install additional TSM filesets.
$ updateios -fs tivoli.tsm.client.ba.32bit -dev /dev/cd0
- Verify TSM installed by listing software installed.
$ lssw
Sample output:
..
tivoli.tsm.client.api.32bit 6.2.2.0 CF TSM Client - Application Programming
Interface
Fixes included in this release
| APAR | Description |
|---|---|
| IV11065 | LDAP USERPRINCIPALNAME ATTRIBUTE FORMAT IS TRUNCATED |
| IV52705 | -migrate -auto flags from HMC doesn't work for link agg device |
| IV52962 | CAA MKCLUSTER FAILS IF REPOSITORY DISK IS EMC CLARIION/INVISTA |
| IV52970 | ethchan_config command will exit with 0 even if command failed |
| IV52991 | Incorrect freespace, capacity reported for a recently created VG |
| IV52995 | ETHER_ATON DOES NOT VALIDATE THE INPUT AS EXPECTED |
| IV53369 | ERRPT ETHERCHANNEL RECOVERY MESSAGE MISSING |
| IV53373 | Inventory for media repository files may fail due to long name |
| IV53376 | PROBLEMS SVC LUN LEADS TO LONG FAIL TIMES, POSSIBLE SSP |
| IV53379 | Possible ioctl hang when S/N changes on opened disk. |
| IV53381 | HMC CRASHES OR OUTPUTS "CHILD PROCESS RETURNED ERROR" ON THE |
| IV53396 | topas -G exits without showing any cluster statistics |
| IV53634 | ADD OPTION TO REMOVE HERALD ATTRIBUTE WITH LOGINMSG COMMAND |
| IV53635 | procfiles and proccred shows negative value for uid and gid |
| IV53636 | lsuser ALL option along with usernames doesn't throw error |
| IV53640 | getaddrinfo cannot handle IPv6 scope/zone |
| IV53654 | Diags may pass even if a failure is present. |
| IV54203 | System crash during high load causing negative runq load value |
| IV54284 | NPIV IO request times out in protocol driver. |
| IV54317 | AUDIT START FAILS SETTING ROLE BASED AUDIT CLASSES |
| IV54354 | Diagnostics does not run on 10Gb and 1Gb FCoE SR, LR, Cu adapter |
| IV54415 | Unable to connect to DB after installing SP1 |
| IV54420 | CAA: CLCOMD HANGS WHEN CLUSTER SECURITY CONFIGURED |
| IV54512 | AIX crashed during rmdev of fcs# port |
| IV54616 | EEH error after diagnostics is run on 4port 1Gb adapter |
| IV54775 | Cluster creation succeeds with errors |
| IV54776 | LPM validation of client using NPIV will fail when VIOS |
| IV54880 | AUDIT CRASH IN OBJECTCLEAR |
| IV54836 | Update disk ping driver to indicate when node info is stale |
| IV54918 | Network adapter configuration attributes don't update. |
| IV54989 | runque value in topasout -P has to be an average value |
| IV54996 | PAM_AUTH ALLOWS USER LOGIN WITHOUT ASKING PASSWORD IT'S NOT NULL |
| IV55092 | VIO_DAEMON: ERR UNSUPPORTED ADDRESS FAMILY : 0 |
| IV55188 | csm.ivm.server fileset missing |
| IV55263 | mkvdev display wrong message if the Disk is not set max_transfer |
| IV55358 | USR PART REMOVAL FAILURE FOR IOS.CLI.RTE |
| IV55386 | SYSTEM MAY HANG WITH THREADS IN SECOW FUNCTION |
| IV55442 | add/remove failure group fails even when successful |
| IV55488 | fix poold recovery after fatal error in node state change |
| IV55489 | rm any older pool disk cache service registration on kext init |
| IV55490 | xtRead correctly handle non-zero level failures |
| IV55547 | no bridge status in entstat for virtual Ethernet |
| IV55567 | POOL DRIVER ISN'T PINNED AND THUS SYSTEM MAY CRASH |
| IV55569 | Crash at dpuPushSpare+000050 |
| IV55603 | DSI in sea_output |
| IV55632 | DSI crash in storfwork:sfwdAddDisk |
| IV55700 | SHUTDOWN -FR FAILS TO COMPLETE A REBOOT OF THE SYSTEM |
| IV55762 | Join node post phase failure after the node was rebooted |
| IV55763 | VIOS SSP crash in storage pool data range lock path. |
| IV55764 | clstartstop command fails with execute permissions |
| IV55805 | IOSCLI COMMAND MAY RETURN INVALID RESULT |
| IV55807 | AIXPERT MUST DIFFERENTIATE FAILEDRULES FROM NOTAPPLICABLERULES |
| IV55808 | system hangs when filesystem and log are degraded |
| IV55880 | Potential hotadapter hot swap failure |
| IV55883 | HEA CAN LOG ERRORS IF JUMBO PACKET IS RECEIVED |
| IV55884 | DSI IN VLAN_GET_USER |
| IV55952 | MISLEADING POOL ID REPORTED IN ERRPT ENTRY FOR VIO_ALERT_EVENT |
| IV55961 | lsgroup command caches user information when it should not be |
| IV55995 | INCORRECT DESCRIPTION IN ERRPT DURING SEA FAILOVER |
| IV56013 | ioscli chdev -udid |
| IV56019 | OUT-OF-ORDER FROM SENDER WHEN THERE IS HEAVY BIDIRECTIONAL TRAFF |
| IV56021 | TCP REQUEST/RESPONSE STYLE COMMUNICATION MAY HANG AFTER ACK PKT |
| IV56023 | NETWORK PERFORMANCE DEGRADED WHEN SACK IS ENABLED |
| IV56058 | DEADLOCK BETWEEN ELXENT_ENTER_LIMBO AND ELXENT_OUTPUT |
| IV56059 | SSP commands fail during rolling upgrade |
| IV56124 | OPTION -T OF RC.POWERFAIL DOES NOT WORK |
| IV56145 | rmvdev -sea removes device even if an interface is configured |
| IV56147 | TARGET DROPS TARGET FUNCTIONS: NO FUTURE LOGINS WILL BE ALLOWED |
| IV56149 | concurrent LPMs operation fail with EIO error |
| IV56213 | CVE-2013-5211:THE MONLIST FEATURE IN NTPD ALLOWS REMOTE ATTACKS |
| IV56389 | xmtopasagg dies while topasrec/topas -C running. |
| IV56392 | DSI CRASH IN SCSIDISKPIN:POFCMDPROC. |
| IV56457 | aixpert undo fails to restore suid bits |
| IV56464 | SYSTEM DUMP TO SECONDARY DUMP DEVICE CAN FAIL. |
| IV56582 | CRASH IN ROCE UNDER SEA DURING REBOOT |
| IV56721 | PADMIN CAN'T RUN COMMANDS AFTER TOPASREC STOP AND VIOS UPGRADE |
| IV56784 | LSGCL COMMAND DOESN'T DISPLAY VIRTUAL OPTICAL LIBRARY COMMANDS |
| IV56801 | REDUCEVG: THE DEFAULT STORAGE POOL "ROOTVG" CAN NOT BE REMOVED |
| IV56892 | CRASH IN HD_BEGIN WITH SYNCVG -F -P OF STRIPED LV |
| IV57304 | Fix system crash risk on rmdev of PCIe3 SAS adapter. |
| IV57307 | caa does not prevent adding an existing node to the cluster |
| IV57347 | LSPV -CLUSTERNAME |
| IV57411 | SYSTEM HANG IN PGSIGNAL |
| IV57458 | MIG_VSCI CORE DUMPING WHEN UDID HAS % CHARACTER |
| IV57459 | Potential security issue. |
| IV58093 | AIXPERT RULE "HLS_DISRMTDMNS" MAY FAIL WHEN TCB IS ENABLED |
| IV58095 | Disk VPD is missing the serial number |
| IV58096 | SYSTEM CRASH IN IMARK |
| IV58466 | ifconfig enX fails on 1Gports when speed is set to 1GFullDuplex |
| IV58470 | NETWORK PERFORMANCE DEGRADATION ON FC5899 ADAPTER |
| IV58475 | Incorrect return code from Paging devices configuration. |
| IV58477 | Add node failure to the SSP cluster after Remove/Replace PV op |
| IV58481 | SSP Import PV operation fails due to stale entry in the DB |
| IV58489 | Blowfish LPA allows login with partial repeated string |
| IV58765 | EEH ERROR CAUSES KERNEL PANIC IN NDD_USRREQ(). |
| IV58766 | Potential security issue. |
| IV58770 | CAA: "DEADMAN TIMER TRIGGERED" WITH SANCOMM AND SHUTDOWN OF NODE |
| IV58830 | Ack of PPRC event fails with EINVAL unexpectedly |
| IV58833 | Inactive VRM pages are not getting restored |
| IV58834 | Failure of pool I/O operation |
| IV59043 | UNICAST MODE TCPSOCK CONNECTIONS BOUNCING UP/DOWN |
| IV59100 | JFS2 FS MARKED CORRUPT WHEN USING FIND COMMAND NEEDING FSCK RUN |
| IV59112 | rmdisk failure when clone of clone has snapshot |
| IV59113 | rmdisk hangs when file with clone is being modified |
| IV59114 | Console errors after removing snapshot after rmdisk |
| IV59115 | Conole log entries after removing snapshot after rmdisk |
| IV59116 | DSI fileMigrateLogicalExtent during rmdisk |
| IV59158 | SSP 'pv -replace' failure may prevent future 'pv -replace' |
| IV59209 | LOSS OF REPOS AND REBOOT IN UNICAST CLUSTER CAUSES DMS TIMEOUT |
| IV59495 | SEA creation fails with xml error |
| IV59529 | Certain VIOS commands may hang when run through DRM |
| IV59735 | resume of suspended LPAR may fail |
| IV59934 | Failure to do Secure LPM Migration with Tunnels |
| IV59968 | USYSIDENT DIDN'T REPORT THE CORRECT DISK STATUS |
| IV60009 | Crash with Illegal Trap Intruction Interrupt on entcore |
| IV60010 | Resume of client will fail when the reserve is set to PR_SHARED |
| IV60012 | PRIMARY SEA FAILS TO SEND RARP UPDATES IN CERTAIN CASES |
| IV60199 | LPM while using SSP occasionally fails |
| IV60297 | largesend turned on errorneously when ipsec encapsulation is on |
| IV60299 | Potential security issue. |
| IV60300 | Secure LPM may not create tunnels and may cause LPM to abort |
| IV60363 | EEH permanent error seen on new P8 HW |
| IV60384 | Data inconsistency detected in SSP |
| IV60499 | VIOS hang during host side port bounce |
| IV60853 | SSP cluster hangs when concurrent listings are generated |
| IV60904 | FCA_ERR6 THAT DECODES TO NO FREE CMD MIGHT HANG SOME PROCESSES |
| IV60982 | perfprovider might cause performance impact on VIOS nodes of |
| IV61136 | Migrate interface to first device in link agg when removing |
| IV62608 | part command core dumps in topas_nmon in find_sea_child() |
| IV62910 | NEW USER BY VIOS MKUSER COMMAND GETS HARD-CODED USER ATTRIBUTES |
| IV62940 | UPDATE TIMEZONE RULE FILES TO THE LATEST AVAILABLE |
| IV63056 | NIMADM WITH NIMSH AND NIM CACHE VG FAILS AT NIMADM PHASE 8 |
| IV63294 | Physical link up/down errors on ent interfaces |
| IV63913 | CHVG -G CAN FAIL IF FACTOR CHANGE IS REQUIRED |
| IV63923 | AIXPERT -C CAN KILL INETD AND TFTPD |
| IV64034 | ETHERCHANNEL TOTAL FAILURE IN 802.3AD MODE WITH BACKUP ADAPTER. |
| IV64049 | VIOS SHOULD NOT BE FORCED TO REBOOT AFTER MIRRORIOS |
| IV64087 | LVM COMMANDS MAY FAIL ON SVG WITH UNACCOUNTABLE INTERNAL ERROR |
| IV64555 | USER COMMANDS NOT USING INDEX FILES, SUCH AS /ETC/PASSWD.NM.IDX |
| IV64645 | Report error if network POC is missing for too long |
| IV64650 | GETCONF WITH XBS5_ OR POSIX_V6_ ARGUMENTS MIGHT RETURN UNDEFINED |
| IV64845 | IOSCLI CORE DUMP WHILE "LDC -QUERY -DEV ALL" |
| IV64929 | procstack hangs in exit() after it receives sigsegv |
| IV64934 | smitty mkuser fails for security group user |
| IV65017 | NORMAL MODE OPEN FAILS AFTER DIAGNOSTIC OPEN/CLOSE ON DISK |
| IV65023 | COMMAND USERADD DOESN'T SET PRIMARY GROUP PGRP PROPERLY |
| IV65100 | CAA RESTORING CLUSTER FROM CACHE TO 3rd PARTY DISK FAILS |
| IV65200 | trcrpt -s -r is not reporting any data |
| IV65268 | SEA loop detected didn't update trunk adapter state correctly. |
| IV65286 | ENTSTAT/NMON DEGRADES OPEN ADAPTERS RESPONSE TIMES. |
| IV65296 | replacing repository disk fails under the 3rd party disk. |
| IV65429 | caa: include outgoing packets in monitoring ec/sea/vlan traffic |
| IV65473 | CORE DUMP WITH MALLOCOPTIONS POOL_BALANCED |
| IV65474 | VMM CRASH IN V_PFEND DURING PAGEIN |
| IV65539 | ECH_CHAN_RCVRY/ECH_MAIN_CHAN_FAIL ERRPT ENTRIES WHILE REBOOT. |
| IV65559 | CHVG -G VG MAY CAUSE 0516-072 BAD-BLOCK IF DISK BLOCK SIZE IS 4K |
| IV65569 | NIM RESTVG FAILS WHEN NO VG_DATA RESOURCE IS ALLOCATED |
| IV65761 | APPLICATION CRASHES IN MALLOC POOL |
| IV65788 | VIOS CRASHED IN EMUL_SCHEDULE |
| IV65854 | Redundant ADAPTER_DOWN events generated on en1 up/down |
| IV65855 | Set runq and home-srad when restarting bound threads |
| IV66046 | DIAG SERVICE EVENT FAILED - CANNOT REPORT H/W PROBLEM TO SFP |
| IV66054 | varyoffvg w/ passive nodes online in cluster leaves varyon state |
| IV66058 | CLMGR REPLACE REPO <HD> FAILS FOR FIRST RUN FOR 3RD PARTY DISKS |
| IV66060 | MKVDEV LOGS RAS ERROR WITH HYPHENATED FBO BACKING DEVICE |
| IV66115 | SIMULTANEOUS CALLS ON RRHBA_HW_UNINITIALIZE CRASH SYSTEM. |
| IV66176 | INVALID OUTPUT OF VIOSECURE FIREWALL WHEN ICMP RULES SET |
| IV66273 | Start nodes fails as node list shows all nodes status DOWN |
| IV66298 | CRASH IN PAGERUNBIND WHILE FORCE UNMOUNTING A DEGRADED FS |
| IV66304 | ISAKMPD, TMD, IKED, AND IKEV2D ALWAYS SHOW SYSLOG INFORMATION |
| IV66411 | ETHERCHANNEL RECOVERY FAILS WHEN THE PRIMARY ADAPTER LINK IS UP. |
| IV66429 | TWO PROCESSES ACCESSING FILE IN /PROC CAN BOTH HANG. |
| IV66430 | Remote Restart of Client fails |
| IV66432 | COMMAND USERADD DOESN'T SET FILE PERMISSIONS AND DATE PROPERLY |
| IV66501 | Spurious Transmit errors in AIX error log |
| IV66527 | FTP NOT WORKING WITH KRB5LDAP AUTHENTICATION WITH LDAP REGISTRY |
| IV66577 | Cluster create failing with certain names. |
| IV66727 | Network floods when large send is enabled. It rarely happens. |
| IV66733 | Hyperwap quiesce operation times out |
| IV66777 | LSUSER COMMAND DUMPS CORE WHEN "LSUSER ALL" IS CALLED |
| IV66807 | TOPASOUT -A DUMPS CORE AT CHECK_EXISTING |
| IV66869 | inadvertant disabling of p_block_support on P8 |
| IV67090 | VIOSBR -RESTORE FAILED WITH EMC DISK AND POWERPATH |
| IV67097 | SECLDAPCLNTD CORE DUMP WHEN STARTING UP |
| IV67115 | CRASH IN J2_UNMAP+0002E8 |
| IV67125 | Unable to connect to Database after vios restart |
| IV67126 | VIOS can crash during LPM startup under very rear condition. |
| IV67200 | Hostname change may cause requests to fail with retry required. |
| IV67457 | CRON MAY CALCULATE WRONG LEAP YEAR |
| IV67463 | ENABLING 'TCP_FASTLO' OPTION COULD LEAD TO MEMORY LEAK |
| IV67464 | NON PROMPTED INSTALL NEEDS SPECIFIC OPTION SET FOR SECURE BY DEF |
| IV67465 | VIOS HANGS IF UNABLE TO START VASI OPERATION FOR A STREAM |
| IV67469 | IO failed to resume after fw livedump |
| IV67470 | Crash in FC driver. |
| IV67473 | Sleeping driver thread causing system hang during configuration. |
| IV67479 | DSI IN NBC_LOCATE |
| IV67507 | chsp hangs when pool is 100% |
| IV67510 | SYSTEM CRASH IN DBALLOCAG DUE TO ENOSPC |
| IV67512 | libvio dumps core in vioConnectDB() |
| IV67549 | Unregister 3rd party disks on STOP_NODE |
| IV67551 | Hang during rmdisk operation for SFStore |
| IV67553 | System crash during io to offline disk. |
| IV67666 | CRASH WHEN JFS2 WITH NO LOG BECOMES DIRTY AND GETS FORCE-UNMOUNT |
| IV67675 | Potential event loss when chaging event log size |
| IV67677 | Fail to manage system from console after removal of sfwcomm0 |
| IV67729 | BIND ONLY USES THE FIRST SIX DOMAINS IN SEARCH LIST |
| IV67749 | SVMON -D CRASH ON QUERY OF MMAP SEGMENTS |
| IV67868 | During cluster restore, some SSP VTDs are not restored |
| IV67869 | Restoring of the hdiskpowerX devices throws error messages. |
| IV67870 | Unresolved physical location codes for SAS devices |
| IV67879 | cluster commands hang and pool start prevented |
| IV67880 | pool taken offline on all cluster nodes |
| IV67881 | Concurrency error logged after Management Console operations |
| IV67907 | LQUERYLV SECURITY VULNERABILITY (CVE-2014-8904) |
| IV67915 | pool MFS manager deadlock with csCommit |
| IV67916 | SSP cluster nodes unable to start pool after network outage |
| IV67995 | ABEND IN COMPUTE_CRC32 DURING MUSTANG ADAPTER MICROCODE UPDATE |
| IV68001 | SETTING RECEIVE_Q_ELEM HIGH ON CT3 REDRIVER MAKES IFCONFIG HANG |
| IV68242 | memory leak and null pointer issues raised |
| IV68244 | RMSOCK COMPLAINS WITH "GETPROCDATA: MALLOC FAILED" |
| IV68245 | CRASH AFTER DETACHING AN INTERFACE USING ELXENTDD |
| IV68363 | queue_depth for disk/sas/scsd not adjustable to valid values |
| IV68367 | System crashes when missing disks are brought back online. |
| IV68368 | Free space is not reclaimed after removal of thick file. |
| IV68402 | SYSTEM CRASH IN BAD_VNODE_BAD_CALLER IN AHAFS |
| IV68428 | NTP3/NTP4 SECURITY CVE-2014-9293 2014-9294 2014-9295 2014-9296 |
| IV68470 | clmigcheck failed to find possible repository disk |
| IV68651 | DIAG -CS RETURNED 2E43-403: CHECKSUM VERIFICATION TEST FAILED |
| IV68675 | MEMORY LEAK IN LIBPERFSTAT API perfstat_config() |
| IV68714 | multibos may fail |
| IV68751 | SEA CRASHES IN INSERT_LSO_IPV4 |
| IV68874 | NPIV LPM validation changes to filter client and VIOS wwpns. |
| IV68904 | TOPAS SHOWS DISK BUSY % ABOVE 100 |
| IV68930 | READING FROM LOOPBACK CAUSES SYSTEM CRASH LOOP_RW_STRAT+0002B0 |
| IV68939 | CRASH AT XTSERVERUPDATEFRAGMENTEDBLOCK |
| IV68992 | CVE-2014-8769 |
| IV68994 | A potential security issue exists |
| IV69039 | SCTP HEARTBEATS NOT SENT TO PRIMARY PATH AND NO ASSOCIATION FAIL |
| IV69040 | REALLOC() MAY CORRUPT MALLOC META DATA IF DATA ULIMIT IS REACHED |
| IV69111 | DURING UPDATE OPERATION EMGR FAILS TO REBUILD BOOT IMAGE |
| IV69114 | EN0S/EN0T/ENORRECT ADAPTER FIRMWARE IMAGE DOWNLOAD TO |
| IV69226 | DOMAINLESS=TRUE MAY CAUSE LDAP USER TO BELONG TO 'SYSTEM' GROUP |
| IV69311 | MPIO Path recovers too soon when a LUN is unmapped |
| IV69332 | Shared storage pool stale partitions not getting synced. |
| IV69334 | ioslevel changes for AIX 6.1.9.45 release. |
| IV69335 | SSP crash when fragmented block deleted during rebuild. |
| IV69394 | Fix rolling upgrade. |
| IV69450 | FSCK does not report corruption to a specific superblock field |
| IV69485 | ARTEXDIFF SLOW WITH LARGE NUMBER OF USERS AFTER IV47382 |
| IV69499 | VIOS CHTCPIP COMMAND TO CHANGE GATEWAY IP ADDRESS FAILS |
| IV69527 | Heavy transmit data on FC5899/FC1763 results in machine hang |
| IV69530 | Adapter does not recover from EEH. |
| IV69578 | System is unresponsive for commands (fcstat) |
| IV69632 | EEH errors logged in errpt while system reboot/bringup |
| IV69720 | Duplicate addition of Node that is DOWN |
| IV69787 | PCIE2 2-PORT 10GBE SR ADAPTER DOES NOT RESET LINK |
| IV69792 | Possible disk I/O hang on adapter firmware issue. |
| IV69808 | A potential security issue exists |
| IV69868 | STACK-OVERFLOW WHEN IPSEC IS ENABLED ON IPV6-CONFIGURED SYSTEM |
| IV70378 | GETSERVBYNAME SUBROUTINE DOESN'T RETURN PROTOCOL FOR LDAP SERVIC |
| IV70381 | Shared storage pool fragmented block corruption. |
| IV70392 | DAP BASED USER MAY FAIL TO LOGIN WITH SPECIAL CHAR IN PASSWORD |
| IV70422 | CAA NO DMS FOR ISOLATED NODE IF NON-CAA INTERFACES ARE UP |
| IV70454 | SYSTEM CRASH FROM BAD LOCK ADDRESS PASSED BY NPIV_UNBLOCK_LOGIN |
| IV70497 | MAY CRASH IN EAMAPOUT WITH MODS ENABLED |
| IV70654 | SSP LU creation may fail intermittently. |
| IV70802 | VIOS SSP commands cannot connect to DB |
| IV71032 | ioscli lspath command gives a 0 return code on some failures |
| IV71036 | Loss of repos disk access causes many disk errors |
| IV71159 | vio_daemon is repeatedly respawning |
| IV71160 | Error trying to map/access an SSP LU |
| IV71308 | dumpcheck calculates incorrect dump device size for 4k disks |
| IV71314 | ETHERCHANNEL W/SHORT INTERVAL CAUSES SWITCH TO DISABLE PORTS |
| IV71322 | Make unique_id string W3C XML compliant |
| IV71339 | NPIV starves VSCSI while there are available processors |
| IV71482 | NIMADM OPERATION RESOLVES NIM CLIENT RESOURCE NAME INCORRECTLY |
| IV71570 | handle the case of missing pv in change management. |
| IV71581 | ADDRESS UNREACHABLE NOTIFICATION NOT DELIVERED TO THE USER |
| IV71849 | PUTUSERATTR MEMORY LEAK |
| IV72056 | Fails to resume partition with SSP LUs mapped. |
| IV72188 | I/O failure due to SCSI reservation conflict |
| IV73126 | Trace modification increases /var usage |
Summary of fixes in current release (2.2.3.60)
| APAR | Description |
|---|---|
| IV59092 | PMPERFREC SERVICE NOT STARTED ON INSTALL |
| IV61219 | LVM MAY NOT DO CORRECT BAD BLOCK RELOCATION |
| IV63206 | VIOS: viosbr command is failing with error. |
| IV64843 | SYSTEM CRASH IN FP_FSTAT DOING IOCTL TO LOOPMOUNT DEVICE |
| IV65020 | Incorrect array index when accessing number of paths. |
| IV65564 | Missing valid queue depth range for disk/sas/scsd |
| IV65783 | IPv6 largesend over virtual Ethernet |
| IV65906 | Correct ipsec failure to enable proper LPM. |
| IV66113 | Restricting root user to have only local groups for admgroups |
| IV66280 | USB 3.0 adapter is stuck and no devices are seen |
| IV67052 | AMS DATA VALIDATION FAILS |
| IV67228 | SYSTEM CRASH DUE TO RECURSIVE LOCK IN FC5287 DRIVER |
| IV67462 | IPSEC COMMUNICATION FAILS DUE TO INCONSISTENT SAS WHEN RE-KEYING |
| IV67571 | Excessive Interrupt Disablement mitigation |
| IV68261 | joinvg with -f option may not remove missing disk from VG |
| IV68262 | extendvg dumps core during cleanup |
| IV68264 | FC1763 and FC5899 may hog CPU in recovery paths |
| IV68272 | COMPRESS PM OUTPUT FILES |
| IV68835 | Receive section may not start working on FC1763 & FC5899 |
| IV68902 | FC1763/FC5899 does not increment adapter reset count in entstat |
| IV69104 | MALLOCTYPE=3.1_64BIT CAN CAUSE CORE DUMP. |
| IV69355 | SEA LARGESEND CAN CAUSE TCP BAD HEADER OFFSET ON VIRTUAL CLIENT |
| IV69489 | NDD_ENABLE_ADDRESS adds address multiple times on FC1763/FC5899 |
| IV69531 | FC1763/FC5899 IOCTL and KPROC serialization |
| IV69897 | AIX /USR/SYSV/BIN/DF COMMAND REPORTS INCORRECT VALUES |
| IV69902 | LNCENTDD UNUSED PORTS LOGS LNCENT_PLINK_DOWN |
| IV70173 | LOCAL USER LOGIN FAILS WITH LDAP ERROR MESSAGE |
| IV70553 | SAS CD DRIVE MAPPINGS CHANGED WHEN VIOS REBOOTED |
| IV70843 | AIXPERT MAY ADD WRITE PERMISSION TO PROGRAMS |
| IV71649 | CAA: MKCLUSTER FAILS TO CREATE /ETC/CLUSTER/LOCKS DIRECTORY |
| IV71787 | LSCLUSTER DOES NOT RECOGNIZE AN EXISTING NODE NAME |
| IV71806 | PART FAILS TO CREATE TAR FILE AFTER SETTING HIGH SECURITY LEVEL |
| IV72007 | INCORRECT READ MAY OCCUR DURING JOINVG |
| IV72025 | Assert in emfsc_free_cmd_elem |
| IV72063 | Unable to start node after chrepos |
| IV72066 | CLUSTER0 MISSING LEADS TO MKCLUSTER FAILURE |
| IV72122 | NO ERRORS SEEN WHEN DUPLICATE FLAGS IN "NO" COMMAND ARE USED |
| IV72133 | caa: no gossip transmission on boot can lead to split-brain |
| IV72147 | CFGIPSEC NOT PROPERLY HANDLING COMMENTS IN NEXTBOOT FILE |
| IV72379 | SYSTEM MAY CRASH DURING I/O TO STRIPED LV WITH INFINITE RETRY |
| IV72499 | CORE DUMP AFTER FAILED DLOPEN IN 64-BIT PROGRAM |
| IV72562 | SFW SFWCOM APPEARS UP TO CAA WHEN IT IS NOT FUNCTIONAL |
| IV72705 | FSCK HANGS WHILE REPAIRING ACL INODE |
| IV72781 | IPSECSTAT DISPLAYING NEGATIVE VALUES |
| IV72893 | CLCOMD CAN USE TOO MUCH CPU WHEN AHAFS NOT ACCESSIBLE |
| IV72905 | Fixing the static code analyser issues for elxentdd driver |
| IV73000 | INCORRECT DETAIL IN VIOD_ALERT_EVENT IF CM DB FS CANNOT BE CHECK |
| IV73156 | LVM ops on mirror pool LVs in VGs with many disks can be slow |
| IV73202 | mklv on 4K block disk dumps core |
| IV73203 | EN0S/T,EN0U/V,EN0W/XILSIN NIM DIAG MODE FOR |
| IV73257 | Clients do not see SSP LUs after VIOS reboots |
| IV73259 | SUPPORT FOR CRITICAL VG ATTRIBUTE ALT_DISK_COPY/ALT_DISK_INSTALL |
| IV73437 | rmcluster failure in large clusters |
| IV73440 | SYSTEM CRASH IN DOUBLE FREE SCSIDISK_CONFIG |
| IV73516 | CRASH DOUBLE FREE IN SCSIDISK_TERM_MPIO |
| IV73528 | ARTEXGET IS SLOW WITH LARGE NUMBER OF COMMANDS TO EXECUTE |
| IV73529 | Possible crash at boot time in pkcs11 |
| IV73567 | SSP cluster creation failed on VLAN device |
| IV73572 | topas -C shows incorrect data for APP, PSz |
| IV73573 | Cluster services may not start after reboot of remote site node |
| IV73642 | LSDEV -TYPE ENT4SEA EXCLUDES ROCE ADAPTER |
| IV73758 | EXECUTING STOPSRC -G IKE CAN HANG TMD |
| IV73768 | EXTENDVG OF CONC VG MAY FORCE THE VG OFFLINE ON REMOTE NODE |
| IV73769 | system crash in hd_reduce(), lvm layer |
| IV73770 | joinvg in concurrent VG may put disks in missing |
| IV73838 | caa: inactive node fails to generate remote node_up ahafs event |
| IV73951 | I/O may hung during SCSI ACA Error Condition. |
| IV73976 | A potential security issue exists CVE-2014-3566 |
| IV74100 | varyon/varyoff of conc VG doesn't keep remote timestamp in sync |
| IV74104 | chvg -l will not disable multi-node-varyon-protection |
| IV74178 | LUN discovery may fail during cfgmgr on NPIV Client. |
| IV74329 | CVE-2015-0261 and CVE-2015-2154 tcpdump vulnerablity fix |
| IV74423 | Adapter goes unresponsive and rmdev also hangs |
| IV74424 | INFINIBAND HANG IN ICMCLOSE USING IBSTAT |
| IV74425 | VIO Adapter statistics displays misaligned Virtual Memory Info. |
| IV74484 | ENTSTAT ON SEA FAILS WITH ENTSTAT_MODE ENVIRONEMT VARIABLE |
| IV74508 | Remove dkstat structure for loopdd (loopback) if CFG_INIT fails |
| IV74540 | CRON AND AT JOBS NOT WORKING FOR DOMAINLESS USERS |
| IV74606 | ALT_DISK_COPY ON 4K DISK TRIGGERS LVM_IO_FAIL |
| IV74650 | caa: repository disk replacement may fail |
| IV74780 | caa: high cpu utilization in aha_rcv process |
| IV74837 | System crashes after usb drive reconnect, and umount of FS |
| IV74927 | A potential security issue exists CVE-2015-2808 |
| IV74946 | clconfd lvm conflict with chrepos |
| IV74990 | POOLADM PPSECTOR COMMAND CAN HANG THE POOL |
| IV74992 | SSP POOL MAY DO EXCESSIVE ERROR RECOVERY |
| IV75001 | MIGRATEPV FAILURE MAY CAUSE IO HANG IN CONCURRENT VG |
| IV75041 | MEMORY LEAKS RELATE TO GET_NIS_ENTRY ROUTINE |
| IV75053 | Point to Point connection establishment may fail |
| IV75251 | SolidDB has wrapped memory growth due to unclosed connections |
| IV75253 | FG create failed after replacing PVs |
| IV75273 | LSLDAP KEEPS ON FAILLING WHEN LDAP SERVER CLOSES CONNECTION |
| IV75364 | CAA: UNEXPECTED START_NODE BY PEER NODE LEADS TO AST PANIC |
| IV75385 | Improved driver's fairness logic to avoid I/O starvation |
| IV75387 | CAA: SYSTEM WILL CRASH IF GOSSIP PACKET HAS ID = 0 |
| IV75388 | updateios gives incorrect error codes/messages for some options |
| IV75490 | set fsize to unlimited while creating new user on VIOS |
| IV75495 | CODEGCHECK MIGHT FAIL WITH FALSE ERROR, DISPLAYING SCRIPTED |
| IV75534 | New mirror copies not balanced in replica set. |
| IV75538 | caa: defined pv that matches repo pvid causes mkcluster to fail |
| IV75589 | SYSTEM CRASHES IN ICMCLOSEQP1 |
| IV75590 | Support of UDP RSS hash for FC5899 |
| IV75620 | solid DB has many sockets to perfprovider in CLOSE_WAIT state |
| IV75625 | System loses network connection about 15 minutes after restart. |
| IV75738 | LSSEC PERFORMANCE SUFFERS WHEN EFS IS ENABLED |
| IV75761 | Cluster fails to commit. |
| IV75891 | clmigcheck should automatically assign disk PVIDs |
| IV75892 | An invalid /etc/cluster/rhosts file might not be detected. |
| IV76050 | THE UUID_CREATE SUBROUTINE MAY CREATE DUPLICATE UUIDS |
| IV76129 | xmtopas might restart on any start of any of its consumers |
| IV76130 | Invalid repository reserve policy not detected on remote nodes |
| IV76151 | IKED LOOPS AND CAUSES CPU LOAD WHEN 0-BYTE DATAGRAM IS PRESENT |
| IV76214 | VIO Change Mgmt daemon can core dump |
| IV76215 | LUN discovery may fail during cfgmgr |
| IV76216 | LUN discovery may fail during cfgmgr |
| IV76218 | System crash in pkcs11:P11_SESS_acquire_obj() |
| IV76219 | caa: reduce the number of lock tries in stop/start |
| IV76252 | PASSWORD AGING DOESN'T WORK FOR LDAP IF LDAP USES LOCAL DEFAULTS |
| IV76257 | Incorrect SRN 2E17-203 displayed for VPD failure |
| IV76260 | PERFSTAT KERNEXT DOES DSI IN PTX_LOAD_IFNET_HELPER64 |
| IV76503 | POSIX_SPAWN FUNCTIONS MAY CORE DUMP IN 64-BIT PROGRAM |
| IV76508 | EFSENABLE -D WRT LDAP OPERATION FAILS IN SOME SCENARIOS |
| IV76531 | LPM fails with PCIDMA errors in errpt on target/destination |
| IV76532 | Potential core dump in MPIO command library |
| IV76533 | Possible I/O error during a Hyperswap failover |
| IV76537 | Missing last path failure reason for PG SN mismatch |
| IV76723 | CAA UNICAST CLU: DMS ON LAST NODE DUE TO INCORRECT DPCOM STATE |
| IV76806 | LSGROUP INCORRECTLY CACHES LDAP USER INFORMATION |
| IV76820 | I/O stress on large number of LUNs may cause poor performance |
| IV76821 | 'devrsrv' command to force clear SCSI-2 reserve on a vSCSI fails |
| IV76975 | panic_trap in entcore_tx_enqueue() function. |
| IV77166 | Number SAS RAID hdisks in order of drive slots |
| IV77175 | CAA: MERGE FAILURE DUE TO STALE JOIN_PENDING FLAG. |
| IV77177 | Address failures/limitations with viosdevattr profile. |
| IV77182 | cluster Restore may fail in 1 node cluster with PowerVC |
| IV77475 | ADD FOR POWERVC RESERVE_LOCK POLICY USING EMC 5.3.0.6 OR OLDER |
| IV77520 | NETWORK ADAPTERS PHYSICAL LOCATION MAY NOT BE SHOWN |
| IV77525 | scsidisk_close fails to clear the PR reservation |
| IV77529 | DISK NORMAL OPEN FAILS WITH EACCES |
| IV77530 | devrsrv opening the disk with SC_SINGLE affect disk open |
| IV77531 | SFW_OPENING state might be set for a disk after open failures |
| IV77616 | Bell3 adapter failing on aixerr and STX |
| IV77885 | IVM serviciability features broken without Java5 |
| IV77928 | For PCIe2 4-Port 8Gb FC Adapter attributes smitty does not work |
| IV77932 | Crypto device driver crashes y4_eeh_read_slot+000368 |
| IV78112 | mklvcopy allows upperbound greater than VG's upperbound |
| IV78115 | Running diags leaves an FC Adapter port in DIAGNOSE state. |
| IV78116 | FC1763 & FC5899 may successfully pass corrupted TCPIP packets |
| IV78117 | vSCSI adapter stops responding |
| IV78294 | USB Mouse does not work on P8 system |
| IV78453 | IMPROVED DRIVER'S FAIRNESS ALGORITHM TO AVOID I/O STARVATION |
| IV78454 | IMPROVED DRIVER'S FAIRNESS LOGIC TO AVOID I/O STARVATION |
| IV78470 | I/O could fail during LPM in certain conditions |
| IV78681 | Client lpar with NPIV virtual driver hangs after migration |
| IV78691 | LPM between P8 to P8 fails using particular compatibilty mode |
Was this topic helpful?