IBM Support

IBM Virtual I/O Server support for Power Systems

Fix Readme


Abstract

Downloads for Workload Partition Manager for AIX

Content

Package information

PACKAGE: Update Release 2.2.4.60
IOSLEVEL: 2.2.4.60

VIOS level is NIM Master level must be equal to or higher than
Update Release 2.2.4.60 AIX 6100-09-11 or AIX 7100-05-02 or AIX 7200-02-02

In June 2015, VIOS introduced the minipack as a new service stream delivery vehicle, as well as a change to the VIOS fix level numbering scheme. Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.

General package notes

Be sure to heed all minimum space requirements before installing.

If you are looking for a specific APAR number or fix, please check the list of fixes included in Update Release 2.2.4.60.

To take full advantage of all the functions available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 2.2.4.60. You may check the firmware versions using the "Fix Level Recommendation Tool" (FLRT).

Microcode or system firmware downloads for Power Systems

The VIOS Update Release 2.2.4.60 includes the IVM code, but it will not be enabled on HMC-managed systems. Update Release 2.2.4.60, like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS.

Update Release 2.2.4.60 updates your VIOS partition to ioslevel 2.2.4.60. To determine if Update Release 2.2.4.60 is already installed, run the following command from the VIOS command line:

$ ioslevel

If Update Release 2.2.4.60 is installed, the command output is 2.2.4.60.

New Feature Information

Non-Volatile Memory express enhancements

Support for Non-Volatile Memory express (NVMe) adapters. NVMe is an industry specification for accessing non-volatile storage via the PCI express (PCIe) interface. Remote management of NVMe from the Hardware Management Console (HMC)is in toleration mode. User may not be able to manage virtual storage from HMC for NVMe based volume group. But it is fully supported from the VIOS command line interface (ioscli), which is the default padmin shell. Full support for HMC management for NMVe is in VIOS 2.2.6 and onwards with a future version of HMC.

VIOS NVMe devices can be used in the following ways:

Installation information

Pre-installation information and instructions

Please ensure that your rootvg contains at least 30GB and that there is at least 4GB free space before you attempt to update to Update Release 2.2.4.60. Run the lsvg rootvg command, and then ensure there is enough free space.

Example:

$ lsvg rootvg 
VOLUME GROUP:       rootvg                   VG IDENTIFIER:  00f6004600004c000000014306a3db3d
VG STATE:           active                   PP SIZE:        64 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      511 (32704 megabytes)
MAX LVs:            256                      FREE PPs:       64 (4096 megabytes)

LVs:                14                       USED PPs:       447 (28608 megabytes)
OPEN LVs:           12                       QUORUM:         2 (Enabled)
TOTAL PVs:          1                        VG DESCRIPTORS: 2
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         1                        AUTO ON:        yes
MAX PPs per VG:     32512                                     
MAX PPs per PV:     1016                     MAX PVs:        32
LTG size (Dynamic): 256 kilobyte(s)          AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
PV RESTRICTION:     none                     INFINITE RETRY: no

Upgrading from VIOS version lower than 2.1.0

If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version 2.1.0 using the Migration DVD.

Note that with this Update Release 2.2.4.60, a single boot alternative to this multiple step process is available to NIM users. NIM users can update by creating a single, merged lpp_source that combines the contents of the Migration DVD with the contents of this Update Release 2.2.4.60, as well as the contents of the 2.2.4.10 release.

A single, merged lpp_source is not supported for VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:

After the VIOS migration is complete, from 1.X to 2.X, you must set the Processor Folding, described here under "Migration DVD":

Instructions to disable Processor Folding are detailed at the link below.
See the "Migration DVD" section:

Upgrading from VIOS version 2.1.0 and above

VIOS Update Release 2.2.4.60 may be applied directly to VIOS level between 2.2.4.0 and 2.2.4.10.

On a VIOS level between 2.2.1.1 and 2.2.3.x, a Single Step update procedure can be used to update to level 2.2.4.60.

Instructions: Single step update

To update to Update Release 2.2.4.60 from a level between 2.2.1.1 and 2.2.3.x in a single step, put the 2.2.4.10 updates in the same location as your 2.2.4.60 updates and do the update using the updateios command.

Before installing the VIOS Update Release 2.2.4.60

Warning: The update may fail if there is a loaded media repository.

Instructions: Checking for a loaded media repository

To check for a loaded media repository, and then unload it, follow these steps.

  1. To check for loaded images, run the following command:

    $ lsvopt
    The Media column lists any loaded media.

  2. To unload media images, run the following commands on all Virtual Target Devices that have loaded images.

    $ unloadopt -vtd <file-backed_virtual_optical_device >

  3. To verify that all media are unloaded, run the following command again.

    $ lsvopt
    The command output should show No Media for all VTDs.

Instructions: Migrate Shared Storage Pool Configuration

The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 2.2.4.60 using rolling updates.

Version specific instructions: Version 2.2.1.3 or earlier.

A cluster that is created and configured on a VIOS Version at 2.2.1.3 or earlier must be migrated to version 2.2.1.4 or 2.2.1.5 prior to utilizing rolling updates. This allows the user to keep their shared storage pool devices.

Version specific instructions: Version 2.2.1.4 or later.

The rolling updates enhancement allows the user to apply Update Release 2.2.4.60 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

Instructions: Verify the cluster is running at the same level as your node.

  1. Run the following command:

    $ cluster -status -verbose

  2. Check the Node Upgrade Status field, and you should see one of the following terms:

    UP_LEVEL: This means that the software level of the logical partition is higher than the software level the cluster is running at.

    ON_LEVEL: This means the software level of the logical partition and the cluster are the same.


Installing the Update Release

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.

Instructions: Verifying VIOS update files.

To verify the VIOS update files, follow these steps:

  1. $ oem_setup_env
  2. Create a link to openssl
    # ln -s /usr/bin/openssl /usr/ios/utils/openssl
  3. Verify the link to openssl was created
    # ls -alL /usr/bin/openssl /usr/ios/utils/openssl
  4. Verify that both files should display similar owner and size
  5. # exit

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

Note : While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

Version specific warning: Versions between 2.2.1.1 and 2.2.3.x

You must put the 2.2.4.10 and 2.2.4.60 on the same location to apply updates in single step. The single step approach fixes an update problem with the builddate on bos.alt_disk_install.boot_images fileset.

Version specific warning: Version 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1

You must run updateios command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.

Run the following command after the step of "$ updateios –accept –install –dev <directory_name >" completes.

$ updateios –accept –dev <directory_name >

Depending on the VIOs level, one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.

MISSING REQUISITES:

     X11.loc.fr_FR.base.lib 4.3.0.0        # Base Level Fileset
     bos.INed 6.1.6.0                      # Base Level Fileset
     bos.loc.pc.Ja_JP 6.1.0.0              # Base Level Fileset
     bos.loc.utf.EN_US 6.1.0.0             # Base Level Fileset
     bos.mls.rte 6.1.x.x                   # Base Level Fileset

Warning: If VIOS rules have been deployed.

When the VIOS is the updated, some of the current rules may revert to the system defaults. Additionally, those changes may have been applied to the system.

If you notice this issue, the default rules can be re-deployed and captured to current rules by running the commands below.

$ rules -o deploy -d
$ rules -o capture

Note: This will overwrite any customized rules in the current rules file.

/home/padmin/rules/vios_current_rules.xml


Applying updates

Warning: If the target node to be updated is part of a redundant VIOS pair, the VIOS partner node must be fully operational before beginning to update the target node.

Note: For VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

Note: The current level of the VIOS must be 2.2.2.1 or later if you use the Share Storage Pool.

Instructions: Applying updates to a VIOS

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.

    $ clstartstop -stop -n <cluster_name > -m <hostname >

  4. To apply updates from a directory on your local hard disk, follow the steps:

    To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:

    1. Mount the remote directory onto the Virtual I/O Server:
      $ mount remote_machine_name:directory /mnt

    The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:

    1. Place the CD-ROM into the drive assigned to VIOS.
    1. Create a directory on the Virtual I/O Server.
      $ mkdir <directory_name >
    2. Using ftp, transfer the update file(s) to the directory you created.
  • Commit previous updates by running the updateios command

    $ updateios -commit

  • Verify the updates files that were copied. This step can only be performed if the link to openssl was created.

    $ cp <directory_path >/ck_sum.bff /home/padmin
    $ chmod 755 </home/padmin>/ck_sum.bff
    $ ck_sum.bff <directory_path >
    If there are missing updates or incomplete downloads, an error message is displayed.

  • Apply the update by running the updateios command

    $ updateios -accept -install -dev <directory_name >

  • To load all changes, reboot the VIOS as user padmin .

    $ shutdown -restart

    Note: If shutdown –restart command failed, run swrole –PAdmin in order for padmin to set authorization and establish access to the shutdown command properly.

  • If cluster services were stopped in step 3, restart cluster services.

    $ clstartstop -start -n <cluster_name > -m <hostname >

  • Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now 2.2.4.60.

    $ ioslevel


Post-installation information and instructions

Instructions: Checking for an incomplete installation caused by a loaded media repository

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command:
$ lsrep

If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

Running the lsvopt command should show the media images.

Instructions: Recovering from an incomplete installation caused by a loaded media repository

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

  1. Unload any media images

    $ unloadopt -vtd <file-backed_virtual_optical_device>

  2. Reinstall the ios.cli.rte fileset by running the following commands.

    To escape the restricted shell:
    $ oem_setup_env
    To install the failed fileset:
    # installp –Or –agX ios.cli.rte –d <device/directory >
    To return to the restricted shell:
    # exit

  3. Restart the VIOS.

    $ shutdown –restart

  4. Verify that the Media Repository is operational by running this command:

    $ lsrep

Additional information

For additional details, including known capabilities, limitations, and additional install considerations, as well as some additional instructions, please reference the Readme for 2.2.4.10 located here.

Fixes included in this release

This version will include all fixes found in all previous 2.2.4.X releases. The fixes for the previous release can be found here.

The list of fixes in 2.2.4.60
APAR Description
IJ00021 scsidisk IOCTL cmd could hang if too many ENXIO errors occur
IJ00170 MEMORY LEAK IN ERRLOG API WHEN USING ERRLOG_FIND_FIRST()
IJ00195 Abort open sequence if PCM fails path
IJ00288 snmpdv3 does not indicate endOfMibView correctly
IJ00289 clmigcheck failing with reservation policy issue
IJ00290 Applying bos.esagent update image may fail
IJ00291 rpcinfo -p not showing service name
IJ00292 RUNNING SNAP CAUSES SYNTAX ERRORS IF RUNS FROM CROWDED DIRS.
IJ00294 FC 5721:INTERFACE DEFINED AT BOOT
IJ00358 ARR MAY FAIL TO VARYOFF AND EXPORT CAAVG WHEN LUNS UNMAPPED
IJ00360 Fixes for possible hang or crash due to locking issues.
IJ00444 Install images for 6100-09-10
IJ00539 MKWPAR FAILED WITH THE OUT OF SPACE ERROR
IJ00540 Handling of WWNN changes in PDISC accept Response
IJ00541 LPAR is hung for a long time
IJ00546 SHELL COMMAND THROWS ERROR WITH USER CAPABILITIES SET
IJ00563 Fix multiple tcpdump CVEs from 9/11/2017
IJ00661 Installation from USB DVD Device fails with open device failure
IJ00703 system crash during DLPAR operation
IJ00743 KSH CORE IF SIGNAL RECEIVED DURING EXIT
IJ00744 ENT PORT USING FC5708 FAMILY ADAPTER CAN NOT BE RMDEV
IJ00745 Diagnostics does not analyze disk errors
IJ00812 BOOT FAILS WITH 0X518 /TMP MNT FAILED
IJ00833 System crash with infinite retry with a bad disk and IO delay
IJ00886 UPGRADE RESETS NTP LINKS
IJ00887 XNTPD CHILD PROCESS NEVER EXITS
IJ00889 Fix autofs cachefs and stnfs major numbers
IJ00904 CDE icon editor crashes while saving XPM format
IJ01231 EFS /TMP FILESYSTEM CAUSES MIGRATION TO FAIL
IJ01232 SNMP SET OF AIXAGENTCMDSTRING IN AIXMIBD TRUNCATED TO 64 BYTES
IJ01233 clcomd generates coredump
IJ01281 chdef command does not change defaults for some disk attributes
IJ01283 MEMORY LEAK DUE TO NFSV4 FILE HANDLES
IJ01494 bos.perf.pmaix installation might fail
IJ01567 mt__trce dumps cores with long
IJ01569 SECLDAPCLNTD HANGS WITH BAD LSLDAP FILTER
IJ01571 IPv6 installation hangs when booting across subnets
IJ01875 AUDIT OBJECTS WON'T WORK ON FILENAME WITH COMMA
IJ01877 ASSERT AT BOOT IN NC_HEALTH_CHECK_WDOG
IJ01879 Adapter running on another version of firmware after update
IJ01882 Cannot add "eventtype=modDir" to rtcd_policy.conf using chsec.
IJ01883 USERMOD -L FAILS IF HOST_LAST_LOGIN IS AN IPV6 ADDRESS
IJ01993 System may crash during I/O striped LVs with Infinite Retry
IJ01994 Fix adapter SMIT ODM
IJ02019 SNAP DOES NOT COLLECT AUTOLOAD WHEN COLLECTING LIVEDUMPS
IJ02134 Setting mac addr using ioctl, ping fails
IJ02193 cache_mgt device should list NVMe devices.
IJ02194 ENOBUFS RETURNED IN ADDING A MULTICAST MEMBERSHIP
IJ02322 Allow PCM ALUA code to be more aggressive switching controllers
IJ02323 cache attribute for a VG may have wrong value.
IJ02324 Improper handling of F3 on successful completion menu
IJ02340 diag cmd fails to dwnload micrcd with -f optn
IJ02423 clcmd hang
IJ02525 CAA CLCOMD CONNECTION REFUSED DURING POWERHA 7.X MIGRATION
IJ02726 A potential security issue exists
IJ02806 iostat -a does not display disk mapped
IJ02895 CRASH IN VS_THREAD_FREE()
IJ03030 A potential security issue exists
IJ03057 kernel abend on tstart() for EEH callbacks
IJ03204 Cache stop may crash the system.
IJ03375 Disk event indicates free when actually in use.
IJ03377 Update Diag CD VRMF for 72H and 71a
IJ03602 Invalid Slot ID firmware download
IJ03634 Adapter dump data might be missing on shientdd device driver
IJ03896 Stress runs over vnic lose connection
IJ03958 ams partition failed with err HSCLA288,HSCLA237
IJ04078 crash @ npiv_dequeue+000014
IJ04228 Some AMS enabled LPARS may not boot or migrate
IJ04357 Deploy or LPM initiated by PowerVC fails
IJ04511 illegal instruction (core dump) in mbrtowc_wrap
IJ04518 boot hangs on P4 full partition
IJ04596 Potential loss of security fixes during LPM to Power7
IJ04859 crash on vios in kcluster_sendmsg_ext()
IV76745 smitty search field filled with the 'n' character
IV84636 BOOTPD DOESN'T FIND ROUTE WITH MANY NETWORK INTERFACES IN USE
IV84705 Create 6.1 IPPs
IV86172 Create 6.1 IPPs
IV86209 Create 6.1 IPPs
IV86209 Reformat RDMA trcfmt macros to print hardware-specific labels.
IV86215 ARTEX support for device attribute settings comparison
IV87170 Diagnostics disk verification fails on 4k SSD
IV87224 Backspace is not working well on dtterm in JA_JP
IV87498 System Crash if print issued without paper in Printer (IBM 5587)
IV87676 SMIT ACCEPT_LICENSE CANNOT COMPLETE DUE TO DE_DE NEIN/JA CASE
IV87792 STRIPNM SHOWING NEGATIVE VALUE FOR SYMBOL SIZE( TLS SYMBOLS )
IV87836 find slow when using "/*" in pathnames on remote filesystems
IV87957 FC5899 ENTSTAT PRINTS 1818495488 FOR BAD PACKET COUNT IN NON-C
IV88406 Add machine credentials to SUMA eCC downloads
IV88546 tttrace generates invalid characters in JA_JP.
IV88739 FC5899 may generate wrong ip_sum for large send packets (LSO)
IV88943 sed command takes more time to execute
IV88964 Possible crash with many (>2000) disks failing a path open.
IV89079 AIX Diagnostics fail on transceiver and loopback tests
IV89439 mkwpar with long name of 255 chars no longer fails
IV89535 SYSTEM CRASH CONFIGURING GXIBDD LHCA INFINIBAND ADAPTER
IV89862 JOIN -V COMMAND GIVES IMPROPER RESULT
IV90091 The DB2 CF server crashes at dapl_evd_wait()
IV90208 RULES COMMAND RETURNS 0590-102 INCORRECT PROFILE ERROR FOR VEA
IV90380 ARTEXSET FAILED TO RESTORE BACKUP MKTCPIPPROFILE.XML
IV90645 Standalone diags asks to unconfigure fcs dev when testing ent
IV90893 DUPLICATE THIN SERVER MAINTENANCE OPTIONS IN SMIT MENU
IV90903 LPSTAT WITH -T AND -P GENERATES CONFUSING OUTPUT
IV91003 PASTE COMMAND GENERATES FILE WITH LESS LINES THAN ORIGINAL FILES
IV91199 DMA errors after increasing num_cmd_elems
IV91385 Test Unit progress message contains a misspelled word
IV91386 dfcscsi might core dump if INT signal is recv'd at right moment
IV91422 SYSTEM CRASH DUE TO DATA CORRUPTION BY SISRAID DRIVER.
IV91435 DIAG MEMORY EXERCISER COREDUMP WITH SIGSEGV IN HTX_FINISH
IV91498 CRASH IN ISCSI CODE DUE TO A NULL SCSI PTR
IV91583 CFGMGR HANG AFTER LPM ON NOT MAPPED NPIV ADAPTER
IV91584 SINGLE THREADED PROCESS HANGS IN LDAP_REQUEST MUTEX LOCK
IV91609 LSTUN CORE DUMPED
IV91801 SNAP -AC ADDS "+" TO /ETC/PASSWD AND ETC/GROUP FILE
IV91810 LS -L MIGHT CUT THE END OF THE
IV92497 MUSENT ERRORS WITH VIOS 2.2.5.X AND IBM I-SERIES CLIENT
IV92865 IFCONFIG/NETSTAT/ENTSTAT HANG DUE TO FAILING LARGE_ALLOC()
IV93269 At jobs fails:cannot accept more jobs into queue
IV93457 Cannot compile Motif UIL in 64bit
IV93457 Create 6.1 IPPs
IV93733 Diagnostics calls out to replace the wrong Power Supply
IV93735 TOPAS -C SHOWS INCORRECT PSZ DATA
IV93972 wrong message in schedo -h for tunable select_intercept_max_fd
IV93973 diagnostic support for 100Gbit RoCE PCIe3 Adapter
IV94224 SMALL LSO PACKETS AND WRONG MSS VALUE
IV94367 proctree for users is incorrect for both LPAR & WPAR
IV94370 XARGS COMMAND DOES NOT HANDLE -L PARAMETER CORRECTLY
IV94439 DUE TO TIMING ISSUE SAS DRIVER MIGHT CRASH THE SYSTEM
IV94445 procmap Total is not resetting for multi proc entry
IV94592 syntax error of positional formatting in struct.msg
IV94890 startlft creates lft when no graphics adapter sw installed
IV94897 FC5899: IFCONFIG/NETSTAT/ENTSTAT HANG DUE TO LARGE_ALLOC
IV95159 FIND -LS DOES NOT LEAVE SPACE AFTER UID OR GID
IV95318 perfprovider reports null value for SEA physicalLocation
IV95527 EN0J AND EN0B ARE DISPLAYED AS PCIe2
IV95749 Bessel function jn wrong results for negative n
IV96043 libcfg: multiple NULL dereferences in cfglog.c
IV96462 DSI DUE TO VLANDD TRANSMIT
IV96499 Disk open/close can hang forever
IV96501 PROCSTACK CORE DUMPS
IV96503 Prevent OBJECT_MODE=64 from overriding -m flag
IV96553 Undetected data loss after storage errors with certain adapters
IV96633 tcptr show may display negative session count
IV96641 Spurious error log from vfchost adapter
IV96663 diff -c/-C/-u/-U should not produce output with identical files
IV96831 FAILGRP STATE NOT UPDATED AFTER MFS FAILOVER
IV96873 AT NOW JOBS RUN AT WRONG TIME NEAR DST CHANGE
IV97012 FAILED SU ATTEMPT INCREMENTS UNSUCCESSFUL COUNT TWICE
IV97020 LARGESEND PACKETS NOT SENT WITH PROPER IP CHECKSUM ON FC 5772
IV97279 POSSIBLE ISI CRASH ON VIOS IN NGDISK_PROC.
IV97280 Pool stop hang during ECC recovery (PMR 32234,001,806)
IV97627 sed standards test failure - comment after space
IV97632 Fix several MPIO/POF related issues.
IV97638 SSP MFS manager inconsistent
IV97715 Repeated EEH events may result in hang
IV97842 batch writes stderr without string
IV97854 Init daemon writes extraneous entries to wtmp
IV97877 VLAN and VLAN IP did not get restored as part of viosbr.
IV97925 complex math routines are not threadsafe
IV97969 SDK 7.0.0 32-bit SR10 FP10 - 17_03
IV97970 SDK 7.0.0 64-bit SR10 FP10 - 17_03
IV98080 ADAPTERS #EN0J IS REPORTING AS PCIE2 INSTEAD OF PCIE3
IV98080 Create 6.1 IPPs
IV98127 crash in net_malloc_cpu while configuring ib
IV98313 migvscsi segfaults in failed remote restart error path
IV98504 Lpar seems to hang after LPM when adapter was closing
IV98527 rm -r with ../ deletes previous directory
IV98528 du reports an error when resolving a symbolic link
IV98530 Configuration commands may hang on the VIOS
IV98577 BASEDN FILTER IS APPENDED TO WRONG BASEDN
IV98790 Fix uninitialized variable in lsmpio command
IV98791 USB DVD I/Os need to be failed on deferred error
IV98792 STARTWPAR LATENCY DUE TO NFS FILE SYSTEMS MOUNT
IV98793 FTPD AUDIT RECORDS ARE NOT RECORDED FOR THE FTP USER
IV98795 alt_disk_copy doesn't allow exclusion of large nfs-mounted file
IV98796 alt_dsisk_copy fails when files exist larger than ulimit allow.
IV98797 'cache_mgt monitor get' command errors out
IV98798 Memory leak in PCM SSP data collection in VIOS.
IV98799 #NAME?
IV98800 RMUSER SHOULD FAIL WHEN USER HAS RUNNING PROCESSES
IV98801 Read did not set variables to the expected values
IV98802 multibos from mksysb failing in 4k disks
IV98803 sh fails when options without option-arguments
IV98805 pselect returned late seconds
IV98807 wide character value is not as expected for mbrtowc().
IV98808 When domainless group is enabled, Fail to delete group
IV98810 Crash in net_kmem_rmlist
IV98811 Unable to change password from nonroot user
IV98826 A potential security issue exists
IV98919 LSTUN COMMAND COULD HANG DURING LPM.
IV98922 Timed-out waiting for child to exit
IV98923 fc -e error is not redirecting to standard error
IV98924 TRUSS REPORTS INCORRECT ARGUMENTS DATA FOR FEW SYSCALLS
IV98925 CAA:CHOOSE_SLOT() FAILURE LEADS TO INTERNODE COMMUNICATION ERROR
IV98926 cache states are shown as inactive after LPM
IV98927 IBM 4767 dd is not returning the Status Request field
IV98942 CHDEV -P SETTING MIN OF A BUF SIZE GREATER THAN MAX SHOULD FAIL
IV99012 SRIOV adapter(lnc2entdd) dump causes backing device failure
IV99013 nim operation hangs when cust script contains unending process
IV99014 perfprovider(srcloop) might coredump sometimes.
IV99015 vrmf mismatch may not boot message during alt_disk_mksysb
IV99016 configassist will be unresponsive in password panel
IV99019 CPLV FROM 512 BLOCK SIZE DISK TO 4K DISK WILL FAIL IN COPYRAWL
IV99020 Cluster creation failed
IV99021 read sets vars incorrectly with tab+nl IFS
IV99024 HANG OCCURS IN _LIBS_CHILD_POST_FORK
IV99028 A vSCSI client may start having I/O timeout failures
IV99028 Create 6.1 IPPs
IV99169 DSI IN STH_REMOVE_STH
IV99172 TRUSS -F MAY HANG IF CHILD TRUSS PROCESS ABORTS
IV99175 system crash @ pm_set_perfm_regs
IV99176 udfcreate causes VIO instance to reboot
IV99209 crash while testing SNMP test bucket
IV99276 FC5270,5708:MPOOL LEAK WHEN MSNENTDD OPEN FAIL
IV99281 PV INVENTORY REPORTS INCORRECT MPIOALGORITHM FOR EMC XTREMIO
IV99293 NVMe drives on a particular adapter all get formatted at once.
IV99294 Fix for incorrect DRM thread creation order
IV99295 LSCFG COREDUMPS ON LONG LOCATION CODES
IV99296 INCORRECT BEHAVIOUR OF CHSEC WHEN DOMAINLESSGROUPS IS ENABLED
IV99297 filemon command coredumps
IV99298 Display Avg write request size and latency with pfcras.
IV99299 crash in sec_thread
IV99300 Undesirable behavior may occur once caching is started.
IV99301 Fix Cache Engine to handle missing pool disks.
IV99303 NFSO COMMAND WITH -P FLAG DOESN'T WRITE INTO NEXTBOOT FILE
IV99304 dtterm doesn't show correct size
IV99305 query fails when 0 repos in kernext
IV99463 Ipcs prints D mode bits for shared memory segments
IV99472 CLOSING A ROCE DEVICE TAKES MORE THAN 1 SECOND
IV99548 A potential security issue exists
IV99586 BACKBYINODE MIGHT LOOP INDEFINITELY IF TTY IS CLOSED
IV99617 SYSLOG LOG MAY SHOW ERRONEOUS "INTERNAL ERROR" LOG ENTRIE
IV99619 bos.pfcdd install log created with wrong mode bits
IV99659 lsmksysb on a USB/UDFS backup may not recognise media
IV99701 System may hang/crash during I/O striped LVs with Infinite Retry
IV99706 VSCSI ADAPTER HANG DUE TO MULTIPLE SRP LOGIN REQUESTS
IV99733 DHCPCD DUMPS CORE IF MORE THAN FOUR INTERFACES ARE SPECIFIED
IV99751 memory leak in svmon code
IV99853 Failing Diagnostics POST Test on crypto adapter
IV99857 BACKBYNAME HANGS ON NFS4 FILE OR MOUNT POINT

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPHKW","label":"PowerVM Virtual I\/O Server"},"Component":"","Platform":[{"code":"PF002","label":"AIX"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date:
19 February 2022

UID

hpc1vios-3171bf8c