PACKAGE: Update Release 2.2.4.50
IOSLEVEL: 2.2.4.50

VIOS level is NIM Master level must be equal to or higher than
Update Release 2.2.4.50 AIX 6100-09-10 or AIX 7100-05-01 or AIX 7200-02-01

In June 2015, VIOS introduced the minipack as a new service stream delivery vehicle, as well as a change to the VIOS fix level numbering scheme. Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.

General package notes

Be sure to heed all minimum space requirements before installing.

Review the list of fixes included in Update Release 2.2.4.50.

To take full advantage of all the functions available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 2.2.4.50.

Microcode or system firmware downloads for Power Systems

The VIOS Update Release 2.2.4.50 includes the IVM code, but it will not be enabled on HMC-managed systems. Update Release 2.2.4.50, like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS.

Update Release 2.2.4.50 updates your VIOS partition to ioslevel 2.2.4.50. To determine if Update Release 2.2.4.50 is already installed, run the following command from the VIOS command line:

$ ioslevel

If Update Release 2.2.4.50 is installed, the command output is 2.2.4.50.

For additional details, including known capabilities, limitations, and additional install considerations, as well as some additional instructions, reference the readme for 2.2.4.10 located here.

Installation information

Pre-installation information and instructions

Please ensure that your rootvg contains at least 30GB and that there is at least 4GB free space before you attempt to update to Update Release 2.2.4.50. Run the lsvg rootvg command, and then ensure there is enough free space.

Example:

$ lsvg rootvg 
VOLUME GROUP:       rootvg                   VG IDENTIFIER:  00f6004600004c000000014306a3db3d
VG STATE:           active                   PP SIZE:        64 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      511 (32704 megabytes)
MAX LVs:            256                      FREE PPs:       64 (4096 megabytes)

LVs:                14                       USED PPs:       447 (28608 megabytes)
OPEN LVs:           12                       QUORUM:         2 (Enabled)
TOTAL PVs:          1                        VG DESCRIPTORS: 2
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         1                        AUTO ON:        yes
MAX PPs per VG:     32512                                     
MAX PPs per PV:     1016                     MAX PVs:        32
LTG size (Dynamic): 256 kilobyte(s)          AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
PV RESTRICTION:     none                     INFINITE RETRY: no

Upgrading from VIOS version lower than 2.1.0

If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version 2.1.0 using the Migration DVD. After the VIOS is at version 2.1.0, the Update/Fixpack 2.2.4.10 must be applied to bring the VIOS to the latest Fix Pack VIOS 2.2.4.10 level. The Update Release 2.2.4.50 can then be applied to bring the VIOS to the latest level.

Note that with this Update Release 2.2.4.50, a single boot alternative to this multiple step process is available to NIM users. NIM users can update by creating a single, merged lpp_source that combines the contents of the Migration DVD with the contents of this Update Release 2.2.4.50.

A single, merged lpp_source is not supported for VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:

After the VIOS migration is complete, from 1.X to 2.X, you must set the Processor Folding, described here under "Migration DVD":

Instructions to disable Processor Folding are detailed at the link below.
See the "Migration DVD" section:

Upgrading from VIOS version 2.1.0 and above

VIOS Update Release 2.2.4.50 may be applied directly to VIOS level between 2.2.4.0 and 2.2.4.10.

On a VIOS level between 2.2.1.1 and 2.2.3.x, a Single Step update procedure can be used to update to level 2.2.4.50.

Instructions: Single step update

To update to Update Release 2.2.4.50 from a level between 2.2.1.1 and 2.2.3.x in a single step, put the 2.2.4.10 updates in the same location as your 2.2.4.50 updates and do the update using the updateios command.

Before installing the VIOS Update Release 2.2.4.50

Warning: The update may fail if there is a loaded media repository.

Instructions: Checking for a loaded media repository

To check for a loaded media repository, and then unload it, follow these steps.

  1. To check for loaded images, run the following command:

    $ lsvopt
    The Media column lists any loaded media.

  2. To unload media images, run the following commands on all Virtual Target Devices that have loaded images.

    $ unloadopt -vtd <file-backed_virtual_optical_device >

  3. To verify that all media are unloaded, run the following command again.

    $ lsvopt
    The command output should show No Media for all VTDs.

Instructions: Migrate Shared Storage Pool Configuration

The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 2.2.4.20 using rolling updates.

Version specific instructions: Version 2.2.1.3 or earlier.

A cluster that is created and configured on a VIOS Version at 2.2.1.3 or earlier must be migrated to version 2.2.1.4 or 2.2.1.5 prior to utilizing rolling updates. This allows the user to keep their shared storage pool devices.

Version specific instructions: Version 2.2.1.4 or later.

The rolling updates enhancement allows the user to apply Update Release 2.2.4.50 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

Instructions: Verify the cluster is running at the same level as your node.

  1. Run the following command:

    $ cluster -status -verbose

  2. Check the Node Upgrade Status field, and you should see one of the following terms:

    UP_LEVEL: This means that the software level of the logical partition is higher than the software level the cluster is running at.

    ON_LEVEL: This means the software level of the logical partition and the cluster are the same.


Installing the Update Release

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.

Instructions: Verifying VIOS update files.

To verify the VIOS update files, follow these steps:

  1. $ oem_setup_env
  2. Create a link to openssl
    # ln -s /usr/bin/openssl /usr/ios/utils/openssl
  3. Verify the link to openssl was created
    # ls -alL /usr/bin/openssl /usr/ios/utils/openssl
  4. Verify that both files should display similar owner and size
  5. # exit

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

Note : While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

Version specific warning: Versions between 2.2.1.1 and 2.2.3.x

You must put the 2.2.4.10 and 2.2.4.50 on the same location to apply updates in single step. The single step approach fixes an update problem with the builddate on bos.alt_disk_install.boot_images fileset.

Version specific warning: Version 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1

You must run updateios command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.

Run the following command after the step of "$ updateios –accept –install –dev <directory_name >" completes.

$ updateios –accept –dev <directory_name >

Depending on the VIOs level, one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.

MISSING REQUISITES:

     X11.loc.fr_FR.base.lib 4.3.0.0        # Base Level Fileset
     bos.INed 6.1.6.0                      # Base Level Fileset
     bos.loc.pc.Ja_JP 6.1.0.0              # Base Level Fileset
     bos.loc.utf.EN_US 6.1.0.0             # Base Level Fileset
     bos.mls.rte 6.1.x.x                   # Base Level Fileset

Warning: If VIOS rules have been deployed.

When the VIOS is the updated, some of the current rules may revert to the system defaults. Additionally, those changes may have been applied to the system.

If you notice this issue, the default rules can be re-deployed and captured to current rules by running the commands below.

$ rules -o deploy -d
$ rules -o capture

Note: This will overwrite any customized rules in the current rules file.


Applying updates

Warning: If the target node to be updated is part of a redundant VIOS pair, the VIOS partner node must be fully operational before beginning to update the target node.

Note: For VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

Note: The current level of the VIOS must be 2.2.2.1 or later if you use the Share Storage Pool.

Instructions: Applying updates to a VIOS

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.

    $ clstartstop -stop -n <cluster_name > -m <hostname >

  4. To apply updates from a directory on your local hard disk, follow the steps:

    To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:

    1. Mount the remote directory onto the Virtual I/O Server:
      $ mount remote_machine_name:directory /mnt

    The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:

    1. Place the CD-ROM into the drive assigned to VIOS.
    1. Create a directory on the Virtual I/O Server.
      $ mkdir <directory_name >
    2. Using ftp, transfer the update file(s) to the directory you created.
  • Commit previous updates by running the updateios command

    $ updateios -commit

  • Verify the updates files that were copied. This step can only be performed if the link to openssl was created.

    $ cp <directory_path >/ck_sum.bff /home/padmin
    $ chmod 755 </home/padmin>/ck_sum.bff
    $ ck_sum.bff <directory_path >
    If there are missing updates or incomplete downloads, an error message is displayed.

  • Apply the update by running the updateios command

    $ updateios -accept -install -dev <directory_name >

  • To load all changes, reboot the VIOS as user padmin .

    $ shutdown -restart

    Note: If shutdown –restart command failed, run swrole –PAdmin in order for padmin to set authorization and establish access to the shutdown command properly.

  • If cluster services were stopped in step 3, restart cluster services.

    $ clstartstop -start -n <cluster_name > -m <hostname >

  • Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now 2.2.4.50.

    $ ioslevel


Post-installation information and instructions

Instructions: Checking for an incomplete installation caused by a loaded media repository

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command:
$ lsrep

If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

Running the lsvopt command should show the media images.

Instructions: Recovering from an incomplete installation caused by a loaded media repository

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

  1. Unload any media images

    $ unloadopt -vtd <file-backed_virtual_optical_device>

  2. Reinstall the ios.cli.rte fileset by running the following commands.

    To escape the restricted shell:
    $ oem_setup_env
    To install the failed fileset:
    # installp –Or –agX ios.cli.rte –d <device/directory >
    To return to the restricted shell:
    # exit

  3. Restart the VIOS.

    $ shutdown –restart

  4. Verify that the Media Repository is operational by running this command:

    $ lsrep

Additional information

For additional details, including known capabilities, limitations, and additional install considerations, as well as some additional instructions, please reference the Readme for 2.2.4.10 located here.

Fixes included in this release

This version will include all fixes found in all previous 2.2.4.X releases. The fixes for the previous release can be found here.

The list of fixes in 2.2.4.50
APAR Description
IV89340 2017 olson timezone database update
IV89961 Create 6.1 IPPs
IV89995 NO SEA FAILOVER ON LNCENT_PLINK_DOWN IN VF MODE
IV90612 SETTING SSP ALERT ON NON-DBN CAUSES MESSAGE STORM
IV91185 VIOSBR RETURN MESSAGE NOT EXPLICIT ABOUT ADDITIONAL STEPS
IV91312 RACE CONDITION FOR IP_MROUTER" LOCK INSIDE "IP_MFORWARD" ROUTINE
IV92399 VIOS CM DAEMON CAN PERFORM EXTRA REPOPULATES IN SOME ODD STATES
IV92425 DK_STAT NOT UPDATED FOR SSP LU
IV92465 CHUSER COMMAND CORRUPTS AFFECTED LDAP GROUPS MEMBER CACHE
IV92848 ALT_DISK_MKSYSB OF MULTIBOS MKSYSB PLACES FILES IN WRONG PATH
IV93029 LDD ERROR "CANNOT FIND LIBTESTLIB.SO" FOR WHITESPACE IN LIBPATH
IV93032 PROBEVUE STACK DEPTH OFTEN INCOMPLETE.
IV93143 SECLDAPCLNTD CORE DUMPS WHEN SERVER GOES DOWN
IV93214 IN SPP CODE IMPROVE ERROR HANDLING FOR TRAVERSAL PHASE OF RMDISK
IV93290 DBX RUN COMMAND DOES NOT PASS -N ARGUMENT TO APP IF USING BASH
IV93292 Incorrect attribute description.
IV93455 multiple nimadm operations fails sometimes
IV93504 Pool meta-root replica set update in infinite retry.
IV93561 WHO FAILS TO HANDLE HUGE UTMP FILE NAME
IV93600 PERFSTAT_SSP ERROR MESSAGE ON THE CONSOLE
IV93732 ICM KERNEL EXTENSION LEAKING TX MAD BUFFERS
IV93871 DUPLICATE NIM CLIENT OBJECTS AFTER SWITCHING TO ALTERNATE MASTER
IV93873 NIS HOME DIRECTORY NOT OBTAINED LOCALLY
IV94028 Recovery deadlock during lock rebuild for new MFS
IV94032 su retains krb5 pag value
IV94034 curt error message needs correction.
IV94062 fcstat -z does not clear statistics from virtual
IV94087 change "lsitab failed" message to clarify that it's a warning.
IV94162 default rules for vendor rules lost after VIOS update
IV94179 updating wrap plug PN for PCIE 8GB 4port Fibre Channel adapter
IV94263 LPM lun level validation fails to get Page 83 Inquiry data
IV94369 HBAapi GetFcpTargetMappingV2 may fail after LPM
IV94416 LDD FAILS TO FIND CORRECT DEPENDENCY FROM LIBRARY
IV94438 vios update and rulescfgset can save/deploy incorrect settings
IV94441 System crash During USB Device Disconnect
IV94442 MKDVD WILL FAIL WITH PID ENVIRONMENT VARIABLE SET
IV94587 Hang in the init command while respawning
IV94793 MKSYSB -T WILL ERROR IF NFS MOUNT EXISTS IN NON-ROOTVG
IV94893 Update SSP maxreadservicetime/maxwriteservicetime unit in pcm
IV94940 VNIC queue negotiation fix
IV95008 nmon reports extra columns in data section for SEACHPHY
IV95102 system crash when using procfs for processes closing many files
IV95122 tag file location changes for ILMT tracking
IV95155 LDD COMMAND ERRORS WITH WHITESPACES
IV95180 Network drivers face abend_trap in Ipv6 tx_path.
IV95204 NPIV FCP command gets truncated in VIOS for some physical HBAs.
IV95348 System may crash during I/O striped LVs with Infinite Retry
IV95350 AggregatedMetrics is blank for big cluster
IV95372 VLAN tagged largesend packets are dropped for some adapters
IV95750 TRUSTED EXECUTION BEING ON MAY RESULT IN INVALID SYSLOG MESSAGES
IV95753 Correct driver flags in entstat output for SEA/etherchannel
IV96038 VIO Server hits CORE_DUMP during create a vnic backing device.
IV96144 When no profile is applied viosecure -c gives error
IV96185 Mirrored SSP, translation is not updated on partition swap
IV96336 pax allows archive filenames > 100 chars
IV96479 The RMC State of VIOS on Novalink is busy
IV96494 WPAR LSATTR -EL SYS0 SHOWS DUPLICATE ATTRIBUTES AFTER LPM
IV96496 System crash during pcishient adapter configuration
IV96535 init_br_chrp miscalculates bootlv offset for second lv mirror
IV96553 Undetected data loss after storage errors with certain adapters
IV96693 alt_disk_copy -T invalid FS_JFS2_BS sizes
IV96793 Crash during shrink @ dbBackSplit.
IV96877 updating adapter via port Y fails after port X passes
IV96880 IPV6 traffic with extension headers may not be transmitted
IV96882 Large send traffic with TCP segment size <224 not transmited
IV97029 Fix for afdasd max TCQ depth
IV97048 ioslevel changes
IV97135 ETHERCHANNEL LINK PORT IN LACP MODE MAY NOT RECOVER
IV97148 CAA:SLOW GOSSIP TRANSMISSION ON BOOT MAY CAUSE PARTIONED CLUSTER
IV97210 Remove Java6 dependency from IVM
IV97269 DOWN nodeB can gens two NODE_DOWN events for stop nodeA
IV97320 NETSTAT/ENTSTAT DOES NOT DISPLAY ROCE DRIVER SPECIFIC STATISTICS
IV97339 System will be unresponsive during heavy stress.
IV97436 update to bos.esagent fails
IV97524 Requisite failure for ios.artex_profile.rte
IV99024 HANG OCCURS IN _LIBS_CHILD_POST_FORK