IBM Support

SE75350 - HTTPSVR TRYING TO RUN RTVUSRPRF ON XML SERVICE OPERATION FAILS
AND CPF7CFD WITH CCSID DIFFERENT THAN 37

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 APAR (Authorized Program Analysis Report)

Abstract

HTTPSVR TRYING TO RUN RTVUSRPRF ON XML SERVICE OPERATION FAILS
AND CPF7CFD WITH CCSID DIFFERENT THAN 37

Error Description

Trying to login to ICC GUI, command RTVUSRPRF is executed with  
XML service. This operation fails and message CPF7CFD is logged
if job CCSID is different than 37                              

Problem Summary

Trying to login to ICC GUI, command RTVUSRPRF is executed with  
XMLSservice. This operation fails and message CPF7CFD is logged
if job CCSID is different than 37.                              

Problem Conclusion

XMLService used to create and open internal source physical file
for REXX in CCSID 37. This is corrected to honor job CCSID for  
internal file operations.                                      

Temporary Fix

Comments

Circumvention


PTFs Available

R730 SI75968  1000

R740 SI75969  1000

Affected Modules


         
         

Affected Publications

Summary Information

Status............................................CLOSED PER
HIPER...........................................No
Component..................................5770DG100
Failing Module..........................RCHMGR
Reported Release...................R730
Duplicate Of..............................




IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB08","label":"Cognitive Systems"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.1.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3; 7.4","Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"5770DG1","Edition":""}]