Abstract

MSGCPFBB93 STRCLUNOD MAY HANG IF OPTION 41 LICENSE NOT VALID
AND DEVICE DOMAIN

Error Description

STRCLUNOD may hang with CPFBB93 message in job log of QCSTCTL if
starting node is in a device domain and the Option 41 license  
key is invalid.                                                
                                                               
The fixing PTF also addresses an issue where MSGMCH3601 could be
seen in QCSTCTL, QCSTCRGM and QHASVR when a DMPCLUTRC is issued.
                                                               
MCH3601 F/QCSTCMN T/QCSTCMN                                    
From module . . . . . . . . :   CSTACK                          
From procedure  . . . . . . :   CstAckQueryMsg                  
Statement . . . . . . . . . :   133                            
To module . . . . . . . . . :   CSTACK                          
To procedure  . . . . . . . :   CstAckQueryMsg                  
Statement . . . . . . . . . :   133                            
Thread  . . . . :   0000000E                                    
Message . . . . :   Pointer not set for location referenced.    
Cause . . . . . :   A pointer was used, either directly or as a
basing pointer, that has not been set to an address.            

Problem Summary

STRCLUNOD may hang with CPFBB93 message in job log of QCSTCTL if
starting node is in a device domain and the Option 41 license  
key is invalid.                                                

Problem Conclusion

The RIQ was not being properly initialized and has been        
corrected.                                                      

Temporary Fix

Comments

Circumvention


PTFs Available

R720 SI67608 PTF Cover Letter   8249
R730 SI67609 PTF Cover Letter   8242

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770SS100
Failing Module.......................... RCHMGR
Reported Release................... R720
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0;V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]