Subscribe to this APAR
By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.
APAR (Authorized Program Analysis Report) |
Abstract
OSP-DB GROUP_PTF_CURRENCY FAILS WITH PSP INFORMATION NOT
AVAILABLE
Error Description
The SYSTOOLS.GROUP_PTF_CURRENCY and SYSTOOLS.GROUP_PTF_DETAILS
views do not return any information from the external PTF feed.
Problem Summary
****************************************************************
* PROBLEM: (SE67091) Licensed Program = 5770SS1 for i 7.1, *
* i 7.2, and i 7.3 *
* Usability of a Product's MAJOR Function *
* The GROUP_PTF_CURRENCY and GROUP_PTF_DETAILS *
* views no longer work since the PSP XML feed was *
* relocated. *
****************************************************************
* USERS AFFECTED: All IBM i operating system users that are *
* dependent on the SYSTOOLS.GROUP_PTF_CURRENCY *
* and SYSTOOLS.GROUP_PTF_DETAILS views. *
****************************************************************
* RECOMMENDATION: Apply PTF SI64490 for i 7.1. *
* Apply PTF SI64491 for i 7.2. *
* Apply PTF SI64492 for i 7.3. *
****************************************************************
The SYSTOOLS.GROUP_PTF_CURRENCY and SYSTOOLS.GROUP_PTF_DETAILS
views do not return any information from the external PTF feed.
Problem Conclusion
The URL used to obtain the live PTF information moved. These 2
views have been updated to use the new URL.
The new sources of PSP provided IBM i PTF Group levels and
detail are:
http://www-01.ibm.com/support/docview.wss?uid=nas4PSPbyNum&aid=1
and
http://www-01.ibm.com/support/docview.wss?uid=nas4SF99725&aid=1,
where SF99725 is an example of how to extract the details for
a
specific PTF Group.
Temporary Fix
*********
* HIPER *
*********
Comments
Circumvention
PTFs Available
R710 SI64490 7192
R720 SI64491 7290
R730 SI64492 7283
Affected Modules
Affected Publications
Summary Information
Status............................................ | CLOSED PER |
HIPER........................................... | Yes |
Component.................................. | 5770SS1DB |
Failing Module.......................... | RCHMGR |
Reported Release................... | R710 |
Duplicate Of.............................. |
System i Support
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information
Document Information
Modified date: