Abstract

RPFT-F/QQQQUERY-T/QQQQUERY-MSGMCH1210 ERROR WHEN SORTING
INTERVALS

Error Description

The MCH1210 error message appears if the following actions are  
taken to sort the intervals in this order:                      
1.  Run GO PERFORM and select option 3, "Print Performance      
Report"                                                        
2.  Select option 1, "System report"                            
3.  Select a specific section to print by entering a 1 next to a
section name (for example, Workload) and pressing the enter key
4.  Select the "Time interval" category                        
5.  Hit a sort function key except F13, such as F14, "Sort      
(count)"                                                        

Problem Summary

The MCH1210 error message appears if the following actions are  
taken to sort the intervals in this order:                      
1.  Run GO PERFORM and select option 3, "Print Performance      
Report"                                                        
2.  Select option 1, "System report"                            
3.  Select a specific section to print by entering a 1 next to a
section name (for example, Workload) and pressing the enter key
4.  Select the "Time interval" category                        
5.  Hit a sort function key except F13, such as F14, "Sort      
(count)"                                                        

Problem Conclusion

There was an error in the query command that was run to perform
the sort. The code has been updated to sort the intervals on the
selection screen correctly for all the sort function keys.      

Temporary Fix

Comments

Circumvention


PTFs Available

R710 SI63162 PTF Cover Letter   7192
R730 SI63161 PTF Cover Letter   7061

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770PT100
Failing Module.......................... RCHMGR
Reported Release................... R730
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0;V7R2M0;V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
28 July 2017