OSP-T/QPMDDISK-MSGMCH1210 CRTPFRDTA FAILS

Error Description

MCH1210 received by QPMDDISK  while CRTPFRDTA is processing disk
data.                                                          

Problem Summary

MCH1210 received by QPMDDISK  while CRTPFRDTA is processing disk
data.                                                          

Problem Conclusion

When processing disk data, it is not always possible to        
distinguish between a counter reset, a counter overflow/wrap,  
and a normal counter increase. Incorrect handling may cause an  
MCH1210 in CRTPFRDTA, or large values being written to the      
QAPMDISK file, which can lead to errors when other tools process
the data.                                                      
                                                               
CRTPFRDTA will no longer attempt to process a disk metric with  
inconsistent data behavior, such as an apparent reset. The      
reported value for such a metric will be zero.                  

Temporary Fix

Comments

Circumvention


PTFs Available

R710 SI49597 PTF Cover Letter   1000

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770SS100
Failing Module.......................... RCHMGR
Reported Release................... R710
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0;V7R2M0","Edition":"","Line of Business":{"code":"","label":""}}]