Abstract
OSP-T/QPMDJOBM-MSGMCH1210 CRTPFRDTA PROCESS_DATA procedure
Error Description
CRTPFRDTA fails posting MCH1210 Receiver value too small to hold
result. From Module . . . . . : QPMDJOBM From Procedure . . . :
PROCESS_DATA Statement . . . . . . : 2522 To Module . . . . . .
: QPMDJOBM To Procedure . . . . : PROCESS_DATA Statement . . . .
. . : 2522 In this case once we started to get the error we got
it on all following collections, system is only rarely iplled so
all collections are created within the same IPL.
Problem Summary
CRTPFRDTA fails with MCH1210 in QPMDJOBM procedure PROCESS_DATA
when processing large current wait time information.
Once this happened it continues on all subsequent collections.
Problem Conclusion
When jobs use no CPU and remain in the same wait, the current
wait time associated with those jobs can become very large. The
MCH1210 happens as this large current wait time information is
converted to the QAPMJOBWTG wait time format. The calculation
has been changed to handle large times.
Temporary Fix
Comments
5770 F/QPMDJOBM MSGMCH1210 OPCS/N PCSS/N RC408 RIDS/PRROJOBM
COMMENTS:
COMMENTS:
COMMENTS:
When jobs use no CPU and remain in the same wait, the current
wait time associated with that job can become very large. The
MCH1210 happens as this large current wait time information is
converted to the QAPMJOBWTG wait time format. The calculation
has been changed to handle large times.
Circumvention
IPL
PTFs Available
Affected Modules
Affected Publications
Summary Information
Status............................................ | CLOSED PER |
HIPER........................................... | No |
Component.................................. | 5770SS100 |
Failing Module.......................... | RCHMGR |
Reported Release................... | R710 |
Duplicate Of.............................. |
System i Support
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information