Abstract

OSP-F/QPMDBUS-MSGMCH0601 CRTPFRDTA more than 256 buses

Error Description

After moving a R611 system to a new box; attempting to do a    
CRTPFRDTA creates empty members and a message MCH0601 is logged
in the joblog.                                                  

Problem Summary

                                                               
CRTPFRDTA supports a maximum of 256 buses  but does not check  
for exceeding this limit.  This results in processing beyond the
end of internally allocated space.                              

Problem Conclusion

                                                               
The number of buses supported by CRTPFRDTA has been increased to
match the limit for the number of buses for which data can be  
captured.  In addition bus processing will stop if the amount of
data collected exceeds this limit.                              

Temporary Fix

Comments

COMMENTS:                                                      

Circumvention


none                                                            

PTFs Available

R710 SI37376 PTF Cover Letter   0096

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770SS100
Failing Module.......................... RCHMGR
Reported Release................... R710
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.1.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0","Edition":"","Line of Business":{"code":"","label":""}}]