IBM Support

SE27124 - MQM400-AMQ8059 RC2292 (UNKNOWN ENTITY) ON CRTMQM

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 APAR (Authorized Program Analysis Report)

Abstract

MQM400-AMQ8059 RC2292 (UNKNOWN ENTITY) ON CRTMQM

Error Description

When the system has more than 4000 users within QMQMADM group,we
                                                               
hit a ERANGE error on GETGRNAM_R, which causes the problem.    

Problem Summary

When the system has more than 4000 users within QMQMADM group,we
                                                               
hit a ERANGE error on GETGRNAM_R, which causes the problem.    
                                                               
<USERS_AFFECTED>                                                
All users if the system has more than 4000 users                
with QMQMADM/mqm as their group.                                
                                                               
Platforms affected:                                            
iSeries                                                        

Problem Conclusion

This problem is fixed in V6.0.2.0 and later releases.          
Whenever we get a non-zero return code with an ERANGE error on  
GETGRNAM_R we extend the buffer to allow for more users.        

Temporary Fix

Comments

Circumvention


Reduce the number of members for the group profile QMQMADM.    

Approximately 4000 members can be handled.                      

PTFs Available

R600 SI47898 PTF Cover Letter   1000

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5724H7206
Failing Module.......................... RCHMGR
Reported Release................... R600
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V6R0M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
11 December 2012