IBM Support

SE26668: OSP XML EXT: MR1123044643 USE CURRENT SCHEMA INSTEAD OF USER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • Fits Reqirement MR1123044643 states:
    SHDX uses CURRENT SCHEMA special register instead of USER
    special register.
    
    XML Extender will use the USER special register as the default
    schema
    for all unqualified tables found in the DAD.  Since the USER
    register
    is read only, it is not possible for a caller to change it's
    value.
    This requirement suggests that XML extender use the CURRENT
    SCHEMA
    special register as the default schema for unqualified tables so
    
    that
    the caller has the ability to set the default schema used by XML
    
    Extender.
    

Local fix

Problem summary

  • Fits Reqirement MR1123044643 states:
    SHDX uses CURRENT SCHEMA special register instead of USER
    special register.
    
    XML Extender uses the USER special register as the default
    schema for all unqualified tables passed as input or found
    in the DAD.  Since the USER register is read only, it is
    not possible for a caller to change it's value.  This
    requirement requests that XML Extender use the
    CURRENT SCHEMA special register as the default schema
    for unqualified tables so that the caller has the ability to
    set the default schema used by XML Extender.
    

Problem conclusion

  • XML Extender will use the CURRENT SCHEMA special
    register to determine the qualifier of unqualified
    database object references.  DB2 sets the initial
    value of CURRENT SCHEMA to the value of the
    USER special register.
    

Temporary fix

Comments

APAR Information

  • APAR number

    SE26668

  • Reported component name

    5722 DB2 UDB XT

  • Reported component ID

    5722DE100

  • Reported release

    530

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-08-18

  • Closed date

    2006-11-03

  • Last modified date

    2008-10-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    SI25507 SI25761

Modules/Macros

  • RCHMGR
    

Fix information

  • Fixed component name

    5722 DB2 UDB XT

  • Fixed component ID

    5722DE100

Applicable component levels

  • R520 PSY

       UP

  • R530 PSY SI28670

       UP08/02/05 I 1000

  • R540 PSY SI25761

       UP06/12/05 P 7107

[{"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSYUVE","label":"DB2 XML Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"530"}]

Document Information

Modified date:
07 January 2022