Error description
STEPS TO REPRODUCE 1. On a machine using an international locale such as Russian, create an XML message containing one or more international characters. 2. Validate the XML against an XSD in the message editor or in a Function action. EXPECTED RESULTS Validation passes or fails according to the XML content. ACTUAL RESULTS The following error is seen on the test console: com.ghc.ghTester.expressions.ParseException: Invalid byte 2 of 3-byte UTF-8sequence.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users testing XML with international locale * **************************************************************** * PROBLEM DESCRIPTION: * * 1. On a machine using an international locale such as * * Russian, an XML message is used containing one or more * * international characters. * * 2. The XML is validated against an XSD in the message editor * * or in a Function action. * * 3. The test fails and the following error is seen on the * * test console: * * * * com.ghc.ghTester.expressions.ParseException: Invalid byte 2 * * of 3-byte UTF-8sequence. * **************************************************************** * RECOMMENDATION: * * Upgrade to Rational Integration Tester v8.5.0 which includes * * a fix for this issue. * ****************************************************************
Problem conclusion
A fix for this issue was provided in version 8.5.0 of Rational Integration Tester.
Temporary fix
Comments
APAR Information
APAR number
PM81781
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-31
Closed date
2013-06-26
Last modified date
2013-06-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
29 October 2021