Error description
Rhapsody 8.1.5 autosaves for project files containing flowports lack a value for the direction; in the repository it is displayed as: direction = ; When loading the autosave (in either 8.1.5 or 8.2) Rhapsody will display a "Bad Value Found" error for each instance of the missing direction.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Rhapsody * **************************************************************** * PROBLEM DESCRIPTION: * * AUTOSAVES CONTAINING FLOWPORT DATA LACK A VALUE FOR * * DIRECTION, RESULTING IN A BAD VALUE FOUND ERROR * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed by setting the direction to InOut once the direction is empty.
Temporary fix
Comments
APAR Information
APAR number
PI82704
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
820
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-07
Closed date
2017-12-04
Last modified date
2017-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R820 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"820","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
19 October 2021