Error description

  • 1) Create new project
    2) Add Activity diagram to default package, open diagram and
    show diagram frame (right-click background).
    3) Add activity parameter to diagram frame. Set direction to
    "out" in features window.
    4) Add activity in diagram and add a pin. Set pin direction to
    "out" in features window.
    5) Draw an object flow from pin to parameter.
    6) Run model check and observe warning:
    
    "Transition's edge is iinconsistent with pin's direction"
    
    Model checker should allow outbound flow from pin to activity
    parameter.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Rhapsody                                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * MODEL CHECK RESULT FOR "TRANSITION EDGE CONSISTENCY" IS      *
    * INCORREC T FOR OUTBOUND                                      *
    * ACTIVITYPIN->OBJECTFLOW->ACTIVITYPARAMETER                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The check was modified to exclude connection between pin and
    parameter with the same direction wrongly recognized as
    erroneous.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI80647

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-04-27

  • Closed date

    2017-12-04

  • Last modified date

    2017-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

  • R820 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"820","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
19 October 2021