A fix is available
APAR status
Closed as program error.
Error description
If there is a class with an operation and the class (and operation) are read only the user can still make updates within the Implementation tab of the operation. The changes are lost when pressing OK since the class (unit) turns out to be read-only. But you shouldn't be allowed to edit the operation body of read-only classes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Rhapsody * **************************************************************** * PROBLEM DESCRIPTION: * * Read only class's operations are editable but changes are * * lost when saved. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Issue fixed now when the package or class is read-only then the implementation tab shall also become read-only.
Temporary fix
Comments
APAR Information
APAR number
PI74984
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
815
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-16
Closed date
2017-06-12
Last modified date
2017-06-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R815 PSN