Error description
The sequence diagram created in Rhapsody 7.6.1 has its layout modified when opening the same project in 8.1.3. The elements are still connected but it takes considerable effort and wasted time to correct the diagram layout when going between the two Rhapsody versions.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Rhapsody 8.1.3 * **************************************************************** * PROBLEM DESCRIPTION: * * SEQUENCE DIAGRAM LAYOUT ALTERED AFTER UPGRADE FROM 761 TO * * 813 * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in Rhapsody 8.2 - Fixed by fixing the place of the elements on the life lines. The partition lines cannot be fixed automatically. To fix them, select one partition line and select Edit->Select->Select Same Type then drag them to the right place.
Temporary fix
Comments
APAR Information
APAR number
PI49095
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
812
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-21
Closed date
2016-12-05
Last modified date
2016-12-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R813 PSN
UP