A fix is available
APAR status
Closed as program error.
Error description
Abstract: This parameter to Get_Its_Reactive in Initialize using Rational Rhapsody in Ada Error Description: If a reactive class has an explicit Initialize constructor and the property Ada_CG.Operation.ThisAccessTypeUsage on this is set to regular or classwide then RiA fails to spot this and does not remove the ''access' that it appends to the 'this' parameter passed to Get_Its_Reactive called within Initialize. Local Fix: NA
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Rhapsody 8.1.1 * **************************************************************** * PROBLEM DESCRIPTION: * * code generator error with reactive class initialization call * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in 8.1.4. Fixed code generator
Temporary fix
Comments
APAR Information
APAR number
PI40616
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
811
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-05-07
Closed date
2015-12-22
Last modified date
2015-12-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R811 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1.1","Line of Business":{"code":"LOB02","label":"AI Applications"}}]
Document Information
Modified date:
17 October 2021