Error description
If you have a process template property set as a select property change it to a text property, you may run into an issue when creating a process that uses the property and does not use the default value. A TemplateWorkflowCreationException is thrown saying that property x is not an allowed value for <property> This also applies to project template properties and source config template properties.
Local fix
1 - Set the property type to Select and clear the Allowed Values field 2 - Alternatively you can delete and re-add the property as a text property
Problem summary
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * Changing a property from select to text leaves in the * * allowed values and causes parts of the UI to try selecting * * any entered values from the allowed values list * **************************************************************** * RECOMMENDATION: * * Apply the latest cumulative patch. Upgrade to 5.0.1.7 or * * 6.1.0.3 when they are released * ****************************************************************
Problem conclusion
Fix is in the latest cumulative patch. Changing a select property to a text property should no longer cause the UI to try selecting any entered values from an allowed values list
Temporary fix
Comments
APAR Information
APAR number
PI38231
Reported component name
UBUILD
Reported component ID
5725M7500
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-04-01
Closed date
2015-08-06
Last modified date
2015-08-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
UBUILD
Fixed component ID
5725M7500
Applicable component levels
R500 PSN
UP
R500 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS4JLT","label":"IBM uBuild"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 October 2021