IBM Support

PI28992: EPI client applications become unresponsive when a non-zero read timeout value is set

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An EPI client application stopped responding after issuing an
    EPI getEvent when a read timeout value was specified on the EPI
    terminal install request.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of the CICS TG EPI API.
    ****************************************************************
    PROBLEM SUMMARY:
    When an EPI application attempted to retrieve a response to a
    transaction request from CICS, CICS TG attempted to use the
    specified read timeout value. This caused a deadlock to occur
    which prevented CICS TG responding to the application.
    ****************************************************************
    

Problem conclusion

  • CICS TG has been corrected. Specifying an EPI terminal with a
    read timeout does not cause the reported deadlock.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI28992

  • Reported component name

    CICS TRNS GATE

  • Reported component ID

    5724I8103

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-11-04

  • Closed date

    2015-02-03

  • Last modified date

    2015-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CICS TRNS GATE

  • Fixed component ID

    5724I8103

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMJ2","label":"CICS Transaction Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: