Error description

  • Headline:
    Adding SysML profile to a UML model breaks the Link element in
    UML
    
    Abstract:
    Attempts to add a SysML profile to a UML model breaks the Link
    element in UML
    
    Error Description:
    Steps to Reproduce:
    
    1. Create a UML model in Rhapsody 8.0.6 C Language
    
    2. Create an object model diagram with 2 objects connected to
    each other by the Link element
    
    3. Add the SysML profile to the model
    
    4. Now try repeating Step 2 and observe the Link element cannot
    be drawn between the 2 objects
    
    This is because of the interference of the SysML element 'Link'
    type with the UML element 'Link'
    
    Hence we cannot use SysML and UML in conjunction within the same
    model
    
    WORKAROUND:
    NA
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Fixed by fixing the creation of NewTerm element in case that
    it is named the same as an out of the box meta class.
    

Problem conclusion

  • Fixed in 8.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI15477

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    806

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-04-08

  • Closed date

    2014-06-02

  • Last modified date

    2014-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

  • R806 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.6","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 June 2014