IBM Support

PH67497: COMPLIANCE_CHECK PRODUCES INVALID 999 WHEN VALIDATING A 5010X223A2 837 FILE WITH A CLM10 FIELD CONTAINING COMPOSITE DELIMETER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The HIPAA compliance_check map produces invalid 999 when
    processing 5010X223A2 837 file containing a CLM10 field that
    includes invalid composite delimiter characters, the resulting
    HIPAA 999 Acknowledgement file includes the CLM10 field data in
    the IK404 Copy of Bad Data Element field.
    
    The result is that the 999 Acknowledgement fails as invalid
    because of the composite delimiter characters IK404 Copy of Bad
    Data Element field.
    
    Recommended using a different composite delimiter in the 999 ISA
    
    segment in order to allow the IK404 Copy of Bad Data Element
    field to pass validation.
    
    The 999 documentation indicates that the IK404 is not required
    or situational if the bad data contains invalid characters.
    
    The 999 is reported as Error Code I6 for "Code Value Not Used in
    
    Implementation" and not Error Code 6 for "Invalid Character In
    Data Element".
    
    The following is the IK404 description and situational rule.
    
    IK404  724  Copy of Bad Data Element  O  AN  1/99  Situational
    Description: This is a copy of the data element in error
    Situational Rule: Required unless invalid characters are
    present, data is missing, or the data is from a binary data
    element. If not required by this implementation guide, do not
    send.
    

Local fix

  • ITXCQ - ITX00063027
    LV / LV
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender Pack for Healthcare HIPAA
    
    Problem Description:
    
    HIPAA compliance_check map produces invalid 999 when validating
    CLM10 field containing composite delimiter characters
    
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • Maps updated to handle delimiters while generating 999 File. For
    
    the condition stated below, IK403 will be populated with Error
    Code as 6 "Invalid Character In Data Element" and IK404 will not
    
    be sent.
    
    Applies to:
    Healthcare Pack HIPAA 10.2.1, 10.2.2, 10.2.3
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next fix pack or product release is available,
    check the IBM Transformation Extender product Release Notes
    page:
    https://www.ibm.com/support/pages/node/318755
    
    If a fix pack release is available, download it from Fix
    Central:
    http://www.ibm.com/support/fixcentral/
    
    If a new product release is available, download it from
    PassportAdvantage:
    https://www.ibm.com/software/passportadvantage/pao_customer.html
    
    
    If the fix pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    
    Interim Fix (LAIF) by opening a support Case:
    https://www.ibm.com/mysupport
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH67497

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-07-25

  • Closed date

    2025-08-05

  • Last modified date

    2026-08-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]