IBM Support

PH67190: ITX DESIGN STUDIO CRASHES WHEN IMPORTING A TYPE TREE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ITX Design Studio crashes when importing a Type Tree which has
    presentations containing both Integer and Decimal values where
    the Fraction item used variable syntax.
    

Local fix

  • ITXCQ - ITX00063018
    CN / CN
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender users using Import/Export
    functionality.
    
    Problem Description:
    ITX Design Studio crashes when importing a Type Tree.
    
    Platforms Affected:
    Windows
    

Problem conclusion

  • Fixed an issue with the Type Tree Import. The problem was
    happening in presentations that had both integer and decimal
    values. The root cause was incorrect Fraction syntax for
    variable items.
    
    Applies to:
    10.1.0.2, 10.1.1.1, 10.1.2.1, 11.0.0.0, 11.0.1.1, 11.0.2.0
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next fix pack or product release is available,
    check the IBM Transformation Extender product Release Notes
    page:
    https://www.ibm.com/support/pages/node/318755
    
    If a fix pack release is available, download it from Fix
    Central:
    http://www.ibm.com/support/fixcentral/
    
    If a new product release is available, download it from
    PassportAdvantage:
    https://www.ibm.com/software/passportadvantage/pao_customer.html
    
    
    If the fix pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    
    Interim Fix (LAIF) by opening a support Case:
    https://www.ibm.com/mysupport
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH67190

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A12

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-07-03

  • Closed date

    2025-07-30

  • Last modified date

    2026-08-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A12"}]

Document Information

Modified date: