Error description
The 837P transaction data, which includes the presence of the 2320 AMT_D and the absence of the 2430 SVD and 2330B DTP segments. The transaction failed compliance due to the missing 2330B DTP segment, resulting in a Type 4 rejection under business rule 59252, despite the DTP being reported in IK3 and the 277CA transaction being accepted. Upon analysis, we found that this issue is present in 837P/D/I transactions and is associated with business rules 59252, 59254, and 59253.
Local fix
ITXCQ - ITX00062534 CF / DG Circumvention: None
Problem summary
Incorrect segment location reporting for rules 59252, 59254, and 59253 causes entire transaction to fail when claim level rejection enabled.
Problem conclusion
hcsvu library updated (rules.h) to report segment location at end of claim and not end of transaction for missing DTP segment. Applies to: Healthcare Pack HIPAA 10.1.0, 10.2.0, 10.2.1, 10.2.2. Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next fix pack or product release is available, check the IBM Transformation Extender product Release Notes page: https://www.ibm.com/support/pages/node/318755 If a fix pack release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If a new product release is available, download it from Passport Advantage: https://www.ibm.com/software/passportadvantage/pao_customer.html If the fix pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a support Case: https://www.ibm.com/mysupport
Temporary fix
Comments
APAR Information
APAR number
PH62164
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A11
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-07-03
Closed date
2024-10-01
Last modified date
2024-11-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A11"}]
Document Information
Modified date:
05 November 2024