APAR status
Closed as program error.
Error description
Transformation Extender V10.1.2.0 Pack for Healthcare V10.2.1 Customer testing compliance checking using several different Invalid ISA values. Notice if ISA01 (ISA*00*) is for example ISA*07* the TA1 shows the invalid value: ISA*07* *00* *ZZ*TST1RECEIVER *ZZ*TST1SENDER *240628*1123*^*00501*000000001*0*T*:~ TA1*000000007*010806*1200*R*010~ IEA*0*000000001~
Local fix
ITXCQ - ITX00062566 CF / CF Circumvention: None
Problem summary
Running compliance check document has a invalid ISA01 value, the TA1 shows the invalid value.
Problem conclusion
compliance_check and hipaa_data_compliance maps updated to use valid defaults for ISA qualifier fields in the TA1 response if errors had been reported on those fields in the input ISA of interchange. Applies to: Healthcare Pack HIPAA 10.1.0, 10.2.0, 10.2.1, 10.2.2. Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next fix pack or product release is available, check the IBM Transformation Extender product Release Notes page: https://www.ibm.com/support/pages/node/318755 If a fix pack release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If a new product release is available, download it from Passport Advantage: https://www.ibm.com/software/passportadvantage/pao_customer.html If the fix pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a support Case: https://www.ibm.com/mysupport
Temporary fix
Comments
APAR Information
APAR number
PH62157
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A12
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-07-03
Closed date
2024-10-01
Last modified date
2024-11-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A12"}]
Document Information
Modified date:
05 November 2024