APAR status
Closed as program error.
Error description
Invalid data is passed as valid when using the RESTART/REJECT Function.
Local fix
ITXCQ - ITX00062384 GK / GK Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender users using restart on a record which has record terminators. Problem Description: RESTART/REJECT was passing invalid data as valid. Would occur if restart started one or more bytes too early and count record terminators as data for the next record. Platforms Affected: All
Problem conclusion
Fixed restart issue where invalid data was being passed as valid. Problem was that restart would start 1 byte to early and count a terminator character of the prior good record as the start character for the next record. Applies to: 10.1.2.1, 11.0.0.0 Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next fix pack or product release is available, check the IBM Transformation Extender product Release Notes page: https://www.ibm.com/support/pages/node/318755 If a fix pack release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If a new product release is available, download it from Passport Advantage: https://www.ibm.com/software/passportadvantage/pao_customer.html If the fix pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a support Case: https://www.ibm.com/mysupport
Temporary fix
Comments
APAR Information
APAR number
PH61088
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
B00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-04-25
Closed date
2024-11-04
Last modified date
2024-11-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]
Document Information
Modified date:
05 November 2024