Error description
In an Microsoft Excel spreadsheet, you can have text that spans multiple lines by typing ALT-ENTER. For example if you have a cell that you want to look like: Text Message 1 Text Message 2 In Excel itself, for that cell, you would type: Text Message 1, then type the key sequence of ALT-ENTER and then type Text Message 2 As a text file this is represented as "Text Message 1" followed by a Line Feed, followed by "Text Message 2" When you attempt to write this cell data to a spreadsheet using the Excel adapter, only the last part of the cell data, "Text Message 2", is written to the spreadsheet.
Local fix
ITXCQ - ITX00062452 TR / TR Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender users using the Excel adapter. Problem Description: Excel adapter could not handle Line Feed in data. Platforms Affected: All
Problem conclusion
Problem Conclusion: Excel adapter now handles Line Feed in data. Applies to: 10.1.1.1, 10.1.2.1, 11.0.0.0 Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next fix pack or product release is available, check the IBM Transformation Extender product Release Notes page: https://www.ibm.com/support/pages/node/318755 If a fix pack release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If a new product release is available, download it from Passport Advantage: https://www.ibm.com/software/passportadvantage/pao_customer.html If the fix pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a support Case: https://www.ibm.com/mysupport
Temporary fix
Comments
APAR Information
APAR number
PH61064
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A11
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-04-24
Closed date
2024-11-04
Last modified date
2024-11-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A11"}]
Document Information
Modified date:
05 November 2024